DC input / transistor output combination unit.
[Features]
· A wider range of lineup than the common type in voltage and input/output type.
· External dimensions: (H) 98 mm, (W) 27.4 mm, (D) 90 mm.
[Applications]
· For receiving external ON/OFF signals and transmitting ON/OFF signals externally.
Part Number
Configured Part Number is shown.
| Input Specifications | ||
|---|---|---|
| Input Format | DC input (positive common type) | |
| Number of Inputs | 32 points | |
| Rated Input Voltage | 24 V DC (+20/-15%, ripple ratio within 5%) | |
| Rated Input Current | Approx. 4 mA | |
| ON Voltage / ON Current | 19 V or more / 3 mA or more | |
| OFF Voltage / OFF Current | 11 V or less / 1.7 mA or less | |
| Input Resistance | Approx. 5.6 kΩ | |
| Input Response Time | OFF > ON | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less |
| ON > OFF | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less | |
| Input Common Method | 32 points 1 common | |
| Output Specifications | ||
| Output Format | Transistor output (sink type) | |
| Number of Outputs | 32 points | |
| Rated Load Voltage | 12 to 24 V DC (+20/-15%) | |
| Maximum Load Current | 0.1 A / 1 point, 2 A / 1 common | |
| Maximum Inrush Current | 0.7 A, 10 ms or less | |
| Leakage Current When OFF | 0.1 mA or less | |
| Maximum Voltage Drop When ON | 0.1 V DC (TYP.) 0.1 A, 0.2 V DC (MAX.) 0.1 A | |
| Output Response Time | OFF > ON | 1 ms or less |
| ON > OFF | 1 ms or less (rated load, resistant load) | |
| Surge Suppressor | Zener diode | |
| Fuse | N/A | |
| Protection Function | Overheat Protection Function | Operates independently by point |
| Overload Protection Function | Current limitation at overcurrent detection and during overload protection: 1 to 3 A / 1 point, operated by point | |
| External Power Supply | Voltage | 12 to 24 V DC (+20/-15%) (ripple ratio within 5%) |
| Current | Maximum 15 mA / 1 common (24 V DC, when all points are ON) | |
| Output Common Method | 32 points 1 common | |
| Common Specifications | ||
| Insulation Method | Opto-isolator insulation | |
| Dielectric Strength | 560 V AC rms / 3 cycles (altitude 2,000 m) | |
| Insulation Resistance | 10 MΩ or more on an ohmmeter | |
| Protection Grade | IP2X | |
| Operation Display | 32-point switch display by ON indicator (LED) SW | |
| External Wiring Connection Method | 40-pin connector × 2 | |
| Compatible Connector | A6CON1, A6CON2, A6CON3, A6CON4 (sold separately) | |
| Number of Occupied Inputs/Outputs | 32 points (I/O assignment: 32 input/output combined points) | |
| 5 V DC Internal Current Consumption | 130 mA (TYP. all points ON) | |
| External Dimensions | Height (H) | 98 mm |
| Width (W) | 27.4 mm | |
| Depth (D) | 90 mm | |
| Weight | 0.20 kg | |

Input Derating
| Input Specifications | ||
|---|---|---|
| Input Format | DC input (positive common type) | |
| Number of Inputs | 8 points | |
| Rated Input Voltage | 24 V DC (+20/-15%, ripple ratio within 5%) | |
| Rated Input Current | Approx. 4 mA | |
| Input Derating | N/A | |
| ON Voltage / ON Current | 19 V or more / 3 mA or more | |
| OFF Voltage / OFF Current | 11 V or less / 1.7 mA or less | |
| Input Resistance | Approx. 5.6 kΩ | |
| Input Response Time | OFF > ON | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less |
| ON > OFF | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less | |
| Input Common Method | 8 points 1 common | |
| Output Specifications | ||
| Output Format | Transistor output (sink type) | |
| Number of Outputs | 7 points | |
| Rated Load Voltage | 12 to 24 V DC (+20/-15%) | |
| Maximum Load Current | 0.5 A / 1 point, 2 A / 1 common | |
| Maximum Inrush Current | 4 A, 10 ms or less | |
| Leakage Current When OFF | 0.1 mA or less | |
| Maximum Voltage Drop When ON | 0.2 V DC (TYP.) 0.5 A, 0.3 V DC (MAX.) 0.5 A | |
| Output Response Time | OFF > ON | 1 ms or less |
| ON > OFF | 1 ms or less (rated load, resistant load) | |
| Surge Suppressor | Zener diode | |
| Fuse | 4 A (Non-replaceable) (Fuse cutoff capacity: 50 A) | |
| Fuse Disconnection Indicator | Available (LED display and signal output to CPU in the event of fuse disconnection) | |
| External Power Supply | Voltage | 12 to 24 V DC (+20/-15%) (ripple ratio within 5%) |
| Current | 10 mA (at 24 V DC) | |
| Output Common Method | 7 points 1 common | |
| Common Specifications | ||
| Insulation Method | Opto-isolator insulation | |
| Dielectric Strength | 560 V AC rms / 3 cycles (altitude 2,000 m) | |
| Insulation Resistance | 10 MΩ or more on an ohmmeter | |
| Protection Grade | IP2X | |
| Operation Display | ON Display (LED) | |
| External Wiring Connection Method | 18-point screw terminal block (M3 Screw) | |
| Number of Occupied Inputs/Outputs | 16 points (I/O assignment: 16 input/output combined points) | |
| 5 V DC Internal Current Consumption | 80 mA (TYP. all points ON) | |
| External Dimensions | Height (H) | 98 mm |
| Width (W) | 27.4 mm | |
| Depth (D) | 90 mm | |
| Weight | 0.20 kg | |
| Input Specifications | ||
|---|---|---|
| Input Format | DC input (positive common type) | |
| Number of Inputs | 32 points | |
| Rated Input Voltage | 24 V DC (+20/-15%, ripple ratio within 5%) | |
| Rated Input Current | Approx. 4 mA | |
| ON Voltage / ON Current | 19 V or more / 3 mA or more | |
| OFF Voltage / OFF Current | 11 V or less / 1.7 mA or less | |
| Input Resistance | Approx. 5.6 kΩ | |
| Input Response Time | OFF > ON | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less |
| ON > OFF | 1 ms / 5 ms / 10 ms / 20 ms / 70 ms or less | |
| Input Common Method | 32 points 1 common | |
| Output Specifications | ||
| Output Format | Transistor output (sink type) | |
| Number of Outputs | 32 points | |
| Rated Load Voltage | 12 to 24 V DC (+20/-15%) | |
| Maximum Load Current | 0.1 A / 1 point, 2 A / 1 common | |
| Maximum Inrush Current | 0.7 A, 10 ms or less | |
| Leakage Current When OFF | 0.1 mA or less | |
| Maximum Voltage Drop When ON | 0.1 V DC (TYP.) 0.1 A, 0.2 V DC (MAX.) 0.1 A | |
| Output Response Time | OFF > ON | 1 ms or less |
| ON > OFF | 1 ms or less (rated load, resistant load) | |
| Surge Suppressor | Zener diode | |
| Fuse | N/A | |
| Protection Function | Overheat Protection Function | Operates independently by point |
| Overload Protection Function | Current limitation at overcurrent detection and during overload protection: 1 to 3 A / 1 point, operated by point | |
| External Power Supply | Voltage | 12 to 24 V DC (+20/-15%) (ripple ratio within 5%) |
| Current | Maximum 15 mA / 1 common (24 V DC, when all points are ON) | |
| Output Common Method | 32 points 1 common | |
| Common Specifications | ||
| Insulation Method | Opto-isolator insulation | |
| Dielectric Strength | 560 V AC rms / 3 cycles (altitude 2,000 m) | |
| Insulation Resistance | 10 MΩ or more on an ohmmeter | |
| Protection Grade | IP2X | |
| Operation Display | 32-point switch display by ON indicator (LED) SW | |
| External Wiring Connection Method | 40-pin connector × 2 | |
| Compatible Connector | A6CON1, A6CON2, A6CON3, A6CON4 (sold separately) | |
| Number of Occupied Inputs/Outputs | 64 points (I/O assignment: 64 input/output combined points) | |
| 5 V DC Internal Current Consumption | 130 mA (TYP. all points ON) | |
| External Dimensions | Height (H) | 98 mm |
| Width (W) | 27.4 mm | |
| Depth (D) | 90 mm | |
| Weight | 0.20 kg | |

Input Derating
| Part Number |
|---|
| QH42P |
| QX41Y41P |
| QX48Y57 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Number Of Inputs | Number of Outputs | Features | Max Load Current | Output answer time | Terminal Shape | Number of occupied input/outputs (Point) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,890.00 MYR 1,512.00 | 1 Piece(s) | 4 Day(s) | 6 | 32 | 32 | 32-point 1-common | 0.1A/1 piece | 1 | 40-Pin Connector × 2 | 32 | ||
MYR 1,890.00 MYR 1,512.00 | 1 Piece(s) | 79 Day(s) | 6 | 32 | 32 | 32-point 1-common | 0.1A/1 piece | 1 | 40-Pin Connector × 2 | 64 | ||
MYR 718.33 MYR 574.66 | 1 Piece(s) | 79 Day(s) | 6 | 8 | 7 | 8-point 1-common | 0.5A/1 piece | - | 18-point terminal block | 16 |
Loading...
| Rated Input Voltage(V) | DC24 | Rated load voltage(V) | DC 12–24 | Representative Standard | CE / UL |
|---|---|---|---|---|---|
| Rated input current(mA) | 4 | Input answer time | 1/5/10/20/70 | Type of Unit | DC Input/Transistor Output (Sink) |
| Rated load voltage(V) | DC 12–24 |


MITSUBISHI
Standard Price : MYR 1,680.00-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 563.33-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 723.33-
Days to Ship : 4 Day(s)

MITSUBISHI
Standard Price : MYR 690.00-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 4,320.00-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 698.33-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 1,260.00
Days to Ship : 4 Day(s)

MITSUBISHI
Standard Price : MYR 3,211.67
Days to Ship : 4 Day(s)

MITSUBISHI
Standard Price : MYR 2,278.33
Days to Ship : 97 Day(s)

MITSUBISHI
Standard Price : MYR 761.67-
Days to Ship : 79 Day(s)

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy