CC-Link/LT compatible input/output unit.
[Features]
· One of the smallest in size in the industry.
· Terminal block type, connector type, and cable type.
· Can be used as a remote device station.
[Applications]
· For connections with devices in a field network.
Part Number
Configured Part Number is shown.
The compact unit is one of the smallest in the industry.
You know where to connect to, just by looking at the nameplate on the terminal block.
Input units share a positive common and a negative common.
The terminal block is structured so that 2‑wire method sensors and loads can be connected directly.
Mounting is possible in six orientations.
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL1XY4-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 2 points | 0.1 mA or less | No | 2‑wire method |
| CL1XY8-DT1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Transistor Output | Sink | 12/24 V DC / 0.1 A | 4 points | 0.1 mA or less | No | 2-wire method |
| CL1XY4-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 2 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 2 points | - | No | 2-wire method |
| CL1XY8-DR1B2 | DC Input | Positive Common / Negative Common | 24 V DC / 4 mA | 4 points | 1.5 ms | Relay Output | - | 30 V DC / 250 V AC 2 A | 4 points | - | No | 2-wire method |
The compact unit is one of the smallest in the industry.
Two unit mounting methods, DIN rail and screw mounting, to select from.
3‑wire method sensor input is supported.
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL2XY16-DTP1C5V | DC Input | Positive Common | 24 V DC / 4 mA | 8 points | 0.5 ms / 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 8 points | 0.1 mA or less | Available | 3‑wire/2‑wire method |
The compact unit is one of the smallest in the industry.
Storable in a duct, just like cables.
A communication cable and an external equipment connection cable have been integrated for easy wiring.
Both the communication side and the input/output side come with a cable. (50 cm)
| Type Name | Input Format | Rated Input Voltage / Current | Number of Input Points | Input Response Time | Output Format | Rated Load Voltage / Current | Number of Output Points | Leak Current When OFF | Output Protection Function | External Connection | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CL1XY2-DT1D5S | DC Input | Positive Common | 24 V DC / 4 mA | 1 point | 1.5 ms or less | Transistor Output | Sink | 24 V DC, 0.1 A | 1 point | 0.1 mA or less | No | 3‑wire/2‑wire method |
| Part Number |
|---|
| CL1XY4-DR1B2 |
| CL1XY8-DR1B2 |
| CL1XY8-DT1B2 |
| CL2XY16-DTP1C5V |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Number Of Inputs | Number of Outputs | Rated load voltage (V) | Protection function | Input answer time | Leakage current when OFF (mA) | Output answer time | Terminal Shape | Input target | Rated load current (rated opening/closing current) | External connection | I/O unit power supply current |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 6 | 2 | 2 | AC250V/DC30V | - | 1.5ms | Not applicable | 10.0ms | Screw terminal block | Positive/ Negative Common | 2.0A | 2-line type/2-line type | 60mA | ||
- | 1 Piece(s) | Quote | 6 | 4 | 4 | AC250V/DC30V | - | 1.5ms | Not applicable | 10.0ms | Screw terminal block | Positive/ Negative Common | 2.0A | 2-line type/2-line type | 70mA | ||
- | 1 Piece(s) | Quote | 6 | 4 | 4 | DC12/24V | - | 1.5ms | 0.1mA | 1.0ms | Screw terminal block | Positive/ Negative Common | 0.1A | 2-line type/2-line type | 65mA | ||
- | 1 Piece(s) | Quote | 6 | 8 | 8 | DC24V | Output protection function | 0.5ms/1.5ms | 0.1mA | 1.5ms | Sensor Connectors (e-CON) | Positive Common | 0.1A | 3-line type/2-line type | 50mA |
Loading...
| Rated Input Voltage(V) | DC24V | Rated input current(mA) | 4mA |
|---|




MITSUBISHI
Standard Price : MYR 2,858.33
Days to Ship : 4 Day(s)

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy