- PLC MELSEC-Q Series for Process Control by Mitsubishi electric.
- High-speed, high-accuracy machine control.
- Improved production time with ultra-high-speed processing. (Approx 1.9ns)
- The CPU’s built-in device memory capacity has been increased to a max. of 60K words
- Connection port: USB, RS-232
- Program capacity is up to 252k steps.
- Support increasing control and quality data with high-speed processing.
- A max.
32-character file password can be set for protecting important data.
- Easily connect to CPUs via Ethernet.
Part Number
Configured Part Number is shown.
Q25PHCPU

Q02PHCPU image
| Control Method | Stored Program Repeating Operation | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input/Output Control Method | Refresh Method (Direct access input/output is possible by specifying the direct access input/output (DX, DY).) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Programming Language | Sequence Control Language | Relay symbol language, Logic symbolic language, MELSAP3 (SFC), MELSAP-L, Function block, Structured text (ST) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Process Control Language | FBD for process control | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Processing Speed | Sequence Instruction | LD X0 | 34 ns | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MOV D0 D1 | 102 ns | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Constant Scan | 0.5 to 2,000 ms (can be set in 0.5 ms intervals) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Program Capacity | 28 K steps (112 K bytes) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Memory Capacity | Program Memory (Drive 0) | 112 K bytes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Memory Card (RAM) (Drive 1) | Installed memory card capacity (Max 2 M bytes) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Memory Card (ROM) (Drive 2) | Installed memory card capacity (Flash card: Max. 4 M bytes, ATA card: Max. 32 M bytes) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard RAM (Drive 3) | 128 K bytes | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard ROM (Drive 4) | 112 K bytes | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| CPU Shared Memory | QCPU Standard Area | 8 K bytes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Maximum File Storage Capacity | Program Memory | 28 pcs. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Memory Card (RAM) | 287 pcs. (when Q2MEM-2MBS is used) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Memory Card (ROM) | Flash Card | 288 pcs. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ATA Card | 512 pcs. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard RAM | 3 pcs. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard ROM | 28 pcs. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Maximum Setting Number of Intelligent Function Unit Parameters | Initial Setting | 512 pieces | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Refresh | 256 pcs | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Number of Input/Output Devices | 8,192 points (X/Y0 to 1FFF) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Number of Inputs/Outputs | 4,096 points (X/Y0 to FFF) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Number of Devices | Internal Relay [M] | Default 8,192 points (M0 to 8,191) (variable) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Latch Relay [L] | Default 8,192 points (L0 to 8,191) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Link Relay [B] | Default 8,192 points (B0 to 1FFF) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Timer [T] | Default 2,048 points (T0 to 2,047) (Low-speed timer / High-speed timer shared) (variable) Low-speed timer / High-speed timer is specified by command Measurement unit of Low-speed timer / High-speed timer is set by a parameter (Low-speed timer: 1 to 1,000 ms, 1 ms interval, Default 100 ms) (High-speed timer: 0.1 to 100.0 ms, 0.1 ms interval, Default 10.0 ms) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Integration Timer [ST] | Default 0 point (Low-speed integration timer / High-speed integration timer shared) (variable) Low-speed integration timer / High-speed integration timer is specified by command Measurement unit of Low-speed integration timer / High-speed integration timer is set by a parameter (Low-speed integration timer: 1 to 1,000 ms, 1 ms interval, Default 100 ms) (High-speed integration timer: 0.1 to 100.0 ms, 0.1 ms interval, Default 10.0 ms) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Counter [C] | Normal Counter: Default 1,024 points (C0 to 1,023) (variable) Interruption Counter: Max. 256 points (Default 0 point, set by parameters) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Data Register [D] | Default 12,288 points (D0 to 12,287) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Link Register [W] | Default 8,192 points (W0 to 1FFF) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Annunciator [F] | Default 2,048 points (F0 to 2,047) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Edge Relay [V] | Default 2,048 points (V0 to 2,047) (variable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| File Register [R] | Standard RAM | 32,768 points (R0 to 32,767) Up to 65,536 points can be used by block switching | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SRAM Card (1 M bytes) | 32,768 points (R0 to 32,767) Up to 517,120 points can be used by block switching | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SRAM Card (2 M bytes) | 32,768 points (R0 to 32,767) up to 1,041,408 points can be used by block switching | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flash Card (2 M bytes) | 32,768 points (R0 to 32,767) up to 1,041,408 points can be used by block switching | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flash Card (4 M bytes) | 32,768 points (R0 to 32,767) Up to 1,042,432 points can be used by block switching | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| File Register [ZR] | Standard RAM | 65,536 points (ZR0 to 65,535) Block switching is not necessary | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Loading... Basic Information
Please check the type/dimensions/specifications of the part Q25PHCPU in the PLC MELSEC-Q Series Process CPU series.
Products like this...
Additional Products in this Category
Customers Who Viewed This Item Also Viewed
Tech Support
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy