(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.
Part Number
Configured Part Number is shown.
FX5-16EYR/ES

FX2N-16EX

FX2N-16EX-C

FX2N-16EYR

FX2N-16EYT

FX2N-16EYT-C

FX2N-8EX

FX2N-8EYR

FX2NC-16EX-T
| Ambient Temperature | 0 To 55°C - When operating -25 To 75°C - When saving | ||
|---|---|---|---|
| Relative Humidity | 5 To 95% RH (No Condensation) - When Operating | ||
| Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
| Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
| When Mounting Directly | Frequency: 10 To 57 Hz | Single Amplitude: 0.075 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | |
| Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
| Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
| Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
| Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
| Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter | ||
| Circumstances Of Use | When There Is Not A Large Amount Of Conductive Dust, And No Corrosion Or Flammable Gas | ||
| Frequency Of Use | Cannot Be Used In Pressurized Environments Below 2,000 m. Doing So May Cause Failures. | ||
| Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
| Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
|---|---|
| Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
| Ambient Temperature | 0 To 55°C - When Operating -20 To 70°C - When Saving | ||
|---|---|---|---|
| Relative Humidity | 35 To 85% RH (No Condensation) - When Operating | ||
| Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
| Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
| Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
| Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
| Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
| Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter | ||
| Part Number |
|---|
| FX5-16EYR/ES |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Representative Standard | Features | Applicable sequencer | Number of Inputs (Point) | Number of Outputs (Point) | Terminal Shape | Type of Unit | Number of input channels (ch) | Number of output channels (ch) | Voltage input range (V) | Current input range (mA) | Voltage output range | Current output range | Type of unit | Resistance Load (A/1 Point) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 821.67 MYR 657.34 | 1 Piece(s) | 97 Day(s) | - | - | NA | - | Relay contact output | CE / UL / CUL | - | FX5U / FX5UC | NA | 16 | Terminal block | Output | - | - | - | - | - | - | - | - |
Loading...
Please check the type/dimensions/specifications of the part FX5-16EYR/ES in the MELSEC-F Input/Output Expansion Block series.
| Part Number |
|---|
| FX2N-16EYR |
| FX2N-16EYS |
| FX2N-16EYT |
| FX5-16EYT/ES |
| FX5-16EYT/ESS |
| FX5-32ER/DS |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Representative Standard | Features | Applicable sequencer | Number of Inputs (Point) | Number of Outputs (Point) | Terminal Shape | Type of Unit | Number of input channels (ch) | Number of output channels (ch) | Voltage input range (V) | Current input range (mA) | Voltage output range | Current output range | Type of unit | Resistance Load (A/1 Point) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,146.67 | 1 Piece(s) | 97 Day(s) | 6 | - | NA | 16 | Relay contact output | - | - | FX3UC / FX3GC / FX1NC / FX2NC / FX3G / FX3U / FX1N / FX2N | NA | 16 | Vertical Type Terminal Block | Output | - | - | - | - | - | - | - | - | ||
MYR 1,080.00 | 1 Piece(s) | 79 Day(s) | - | NA | NA | 16 | Triac output | CE / UL | - | FX3UC / FX3GC / FX3G / FX3U | NA | 16 | - | - | - | - | - | - | - | - | Output | - | ||
MYR 1,056.67 | 1 Piece(s) | 97 Day(s) | 6 | - | NA | 16 | Transistor / sync output | - | - | FX3UC / FX3GC / FX1NC / FX2NC / FX3G / FX3U / FX1N / FX2N | NA | 16 | Vertical Type Terminal Block | Output | - | - | - | - | - | - | - | 0.5A/1 piece | ||
MYR 821.67 | 1 Piece(s) | 4 Day(s) | - | NA | NA | - | Transistor / sync output | CE / CUL / UL | - | FX5U / FX5UC | NA | 16 | Terminal block | - | - | - | - | - | - | - | Output | - | ||
MYR 821.67 | 1 Piece(s) | 97 Day(s) | - | - | NA | - | Transistor / source output | CE / CUL / UL | - | FX5U / FX5UC | NA | 16 | Terminal block | Output | - | - | - | - | - | - | - | - | ||
MYR 1,470.00 | 1 Piece(s) | 97 Day(s) | - | 16 | DC24V | 0 | Relay contact output | CE / CUL / UL | Built-in DC power supply | FX5U / FX5UC | 16 | 16 | Terminal block | - | - | - | - | - | - | - | Input/output | - |

MITSUBISHI
Standard Price : MYR 1,056.67-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 1,665.00-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 2,138.33-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 173.33-
Days to Ship : 65 Day(s) or more


MITSUBISHI
Standard Price : MYR 286.67-
Days to Ship : 79 Day(s) or more

MITSUBISHI
Days to Ship : 22 Day(s) or more

MISUMI
Days to Ship : 9 Day(s)

MITSUBISHI
Standard Price : MYR 1,343.33-
Days to Ship : 65 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy