(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Positioning unit (open collector output) for the standard model MELSEC-L series
Part Number
Configured Part Number is shown.
LD75P4

LD75P4 image
| Number of Control Axis | 4 axes | ||
|---|---|---|---|
| Interpolation Function | 2-axis, 3-axis, 4-axis linear interpolation 2-axis circular interpolation 3-axis helical interpolation | ||
| Control Method | PTP (point to point) control Path control (linear, arc and helical) Speed control Speed/position switching control Position/speed switching control | ||
| Single Control Unit | mm, inch, degree, pulse | ||
| Positioning Data | 600 data/axis | ||
| Backup | Parameters, positioning data and block start data can be saved to the flash ROM (battery-less) | ||
| Positioning | Positioning Method | PTP Control | Increment/absolute |
| Speed/Position Switching Control | Increment/absolute | ||
| Position/Speed Switching Control | Increment | ||
| Path Control | Increment/absolute | ||
| Positioning Range | Absolute | -214,748,364.8 to 214,748,364.7 µm -21,474.83648 to 21,474.83647 inches 0 to 359.99999 degrees -2,147,483,648 to 2,147,483,647 pulses | |
| Increment | -214,748,364.8 to 214,748,364.7 µm -21,474.83648 to 21,474.83647 inches -21,474.83648 to 21,474.83647 degrees -2,147,483,648 to 2,147,483,647 pulses | ||
| Speed/Position Switching Control (INC Mode) / Position/Speed Switching Control | 0 to 214,748,364.7 µm 0 to 21,474.83647 inches 0 to 21,474.83647 degrees 0 to 2,147,483,647 pulses | ||
| Speed/Position Switching Control (ABS Mode) | 0 to 359.99999 degree | ||
| Speed Command | 0.01 to 20,000,000.00 mm/min 0.001 to 2,000,000.000 inch/min 0.001 to 2,000,000.000 degree/min 1 to 4,000,000 pulse/s | ||
| Acceleration/Deceleration Processing | Trapezoidal acceleration/deceleration, sigmoid acceleration/deceleration | ||
| Acceleration/Deceleration Time | 1 to 8,388,608 ms Four patterns can be set for acceleration time and another 4 for deceleration time | ||
| Quick Stop and Deceleration Time | 1 to 8,388,608 ms | ||
| Starting Time | 1‑axis Linear Control | 1.5 ms | |
| 1‑axis Speed Control | 1.5 ms | ||
| 2‑axis Linear Interpolation Control (Composite Speed) | 1.5 ms | ||
| 2‑axis Linear Interpolation Control (Reference Axis Speed) | 1.5 ms | ||
| 2‑axis Circular Interpolation Control | 2.0 ms | ||
| 2‑axis Speed Control | 1.5 ms | ||
| 3‑axis Linear Interpolation Control (Composite Speed) | 1.7 ms | ||
| 3‑axis Linear Interpolation Control (Reference Axis Speed) | 1.7 ms | ||
| 3‑axis Helical Interpolation Control | 2.6 ms | ||
| 3‑axis Speed Control | 1.7 ms | ||
| 4‑axis Linear Interpolation Control | 1.8 ms | ||
| 4‑axis Speed Control | 1.8 ms | ||
| Factors for Extended Starting Time | If any of the following conditions are met, the starting time is increased by the applicable time specified below. · Sigmoid acceleration/deceleration selected: 0.1 ms · Other axis operating: 0.5 ms · Continuous positioning control: 0.3 ms · Continuous path control: 0.3 ms | ||
| Pulse Output System | Open collector output | ||
| Maximum Output Pulse | 200 k pulse/s | ||
| Maximum Connected Distance Between Servos | 2 m | ||
| External Wiring Connection Method | - | 40-pin connector × 2 | |
| Compatible Connector | A6CON1, A6CON2, A6CON4 (sold separately) | ||
| Number of Occupied Input/Output | 32 points (I/O assignment: intelligent 32 points) | ||
| 5 V DC Internal Current Consumption | 0.55 A | ||
| External Dimensions | Height (H) | 90 mm | |
| Width (W) | 45 mm | ||
| Depth (D) | 95 mm | ||
| Weight | 0.18 kg | ||
| Part Number |
|---|
| LD75P4 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS |
|---|---|---|---|---|---|
MYR 6,780.00 MYR 5,424.00 | 1 Piece(s) | 97 Day(s) | 6 |
Loading...
| Number of Control Axis | 4 | Positioning data number | 600 pieces of data | Representative Standard | CE / UL |
|---|---|---|---|---|---|
| Single Control Unit | pulse/mm/inch/degree | Positioning data number(Data/Axis) | 600 pieces of data | Number of Control Axis(Axis) | 4 |
| Interpolation function | Available |
Please check the type/dimensions/specifications of the part LD75P4 in the MELSEC-L Series Positioning Unit (Open Collector Output) series.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy