Cable for electronic equipment wiring suitable for wiring on cable trays and raceways
[Features]
▪ Both UL and cUL compliant (Categories: QPOR, AVLV2, ZKHZ and AVLV7).
▪ Conforms to ULVW-1 and cULFT1 flame retardance standards.
▪ Passed the UL vertical tray flame retardance test.
· Uses a flexible vinyl sheath material that is oil and heat-resistant.
・CE Marking Compliant Product (TÜV certified product)(TÜV Certification (18 - 12 AWG) No. J2051249, (10 - 6 AWG) No. J2051252).
· Can be used as tray cable as well.
・10 AWG and under comply with the Electrical Appliance and Material Safety Law
Part Number
Configured Part Number is shown.
UE/2501(N)/TC LF 3X10AWG-91
| Certification | UL AWM. cUL AWM | UL TC | UL MTW | TÜV.CE marking | Electrical Appliances and Materials Safety Act of Japan (18 to 10 AWG only) |
|---|---|---|---|---|---|
| Applicable Standards | UL 758 CSA C22.2 No. 210 | UL 1277 | UL 1063 | EN50525-2-51 | Ministerial Ordinance Specifying Technical Standards for Electrical Appliances |
| Type symbol | UL STYLE 2501 CSA AWM IIA/B | TC | MTW | Equivalent to H05VV5-F | Vinyl flexible cord |
| Rated voltage | 600V | 600V | 600V | 300/500 V | 300V |
| Rated temperature | 105°C | DRY 90°C WET 75°C | DRY 90°C WET 60°C | 70°C | 60°C |
| Conductor | UL 758 CSA C22.2 No. 210 | UL 1277 | UL 1063 | EN60228 | JIS C 3102 JIS C 3152 |
| Flame retardancy | VW-1.FT1 | Vertical-Tray Flame Test | VW-1 | EN50264-2-1 | JIS C 3005 4.26.2 b |

| Number of wire cores | Conductor | Heat Resistant Vinyl Insulator | Oil-resistant, heat resistant, flexible vinyl sheath | Approximate Weight (kg/km) | Electrical Characteristics | |||||||
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter approx. (mm) | Conductor resistance (Ω/km 20°C) | Insulation Resistance (MΩkm 20°C) | Withstand voltage (V/1 min.) | Allowable current (A) | ||
| 2C | 18 (0.823 mm²) | 35/0.18 | 1.2 | 0.85 | 2.9 | 1.7 | 9.4 | 95 | 22.8 or less | 60 or more | 2000 | 19 |
| 3C | 9.9 | 115 | 16 | |||||||||
| 4C | 10.6 | 135 | 15 | |||||||||
| 2C | 16 (1.30 mm²) | 26/0.26 | 1.5 | 0.85 | 3.2 | 1.7 | 10.1 | 115 | 14.3 or less | 60 or more | 2000 | 26 |
| 3C | 10.6 | 140 | 22 | |||||||||
| 4C | 11.4 | 170 | 19 | |||||||||
| 2C | 14 (2.08 mm²) | 41/0.26 | 1.9 | 0.85 | 3.6 | 1.7 | 10.8 | 140 | 9.01 or less | 60 or more | 2000 | 34 |
| 3C | 11.4 | 175 | 28 | |||||||||
| 4C | 12.3 | 210 | 25 | |||||||||
| 2C | 12 (3.30 mm²) | 65/0.254 | 2.4 | 0.85 | 4.1 | 1.7 | 11.8 | 180 | 5.45 or less | 50 or more | 2000 | 45 |
| 3C | 12.4 | 225 | 38 | |||||||||
| 4C | 13.5 | 275 | 34 | |||||||||
| 2C | 10 (5.26 mm²) | 104/0.254 | 3.1 | 0.85 | 4.8 | 1.7 | 13.2 | 240 | 3.44 or less | 50 or more | 2000 | 61 |
| 3C | 13.9 | 305 | 51 | |||||||||
| 4C | 15.2 | 385 | 46 | |||||||||
| 3C | 8 (8.36 mm²) | 7/24/0.254 | 4.2 | 1.7 | 7.6 | 1.7 | 20.0 | 560 | 2.41 or less | 50 or more | 2500 | 67 |
| 4C | 2.3 | 23.1 | 765 | 60 | ||||||||
| 2C | 6 (13.3 mm²) | 7/39/0.254 | 5.3 | 1.7 | 8.7 | 1.8 | 21.2 | 600 | 1.53 or less | 50 or more | 2500 | 100 |
| 4C | 2.3 | 25.8 | 1050 | 79 | ||||||||
* In addition to the above UL and CSA standard withstand voltage tests, it also complies with 2,000 V/5 minute tests requirements.
| Ambient temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.93 | 0.86 | 0.77 | 0.68 | 0.58 | 0.45 | 0.26 |

* Annealed copper stranded wire for 12 AWG and above
(1) For 18 to 10 AWG

(2) For 8 to 6 AWG


Numbers inside the circles indicate the white numbering on the black insulator.
100 m
| Part Number |
|---|
| UE/2501(N)/TC LF 3X10AWG-91 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Conductor Cross Section (mm2) | Number Of Cores (Core) | AWG size 1 (AWG) | Rated Voltage 1 | Shield 1 | Sheath (outer coating) color | Grounding Wire | Overall Length 1 (m) | Properties 1 | Finished outer diameter (mm) | Representative Standard | Sheath (outer coating) material | Insulation body materials | Power supply/signal | Number of Contacts (core) | Conductor Cross-Sectional Area (mm2) | AWG Size (AWG) | Rated Voltage | Safety Standards | Overall Length (m) | Finish Outer Diameter (mm) | Other Properties | Other properties |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 8,117.96 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 91 | 13.9 | - | Flame Retardancy |
Loading...
| Cable Standard | STO/TC / TC | Shield | N/A | Properties | Oil Resistance / Heat Resistance |
|---|---|---|---|---|---|
| Sheath Color | Black | Ground Wires | N/A | Sheath Material | PVC (PVC) |
| Insulator Material | PVC (PVC) |
Please check the type/dimensions/specifications of the part UE/2501(N)/TC LF 3X10AWG-91 in the UE/2501(N)/TC LF Oil-Resistant Tray Power Cable series.
| Part Number |
|---|
| UE/2501(N)/TC LF 2X10AWG-12 |
| UE/2501(N)/TC LF 2X10AWG-13 |
| UE/2501(N)/TC LF 2X10AWG-14 |
| UE/2501(N)/TC LF 3X10AWG-92 |
| UE/2501(N)/TC LF 3X10AWG-93 |
| UE/2501(N)/TC LF 3X10AWG-94 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Conductor Cross Section (mm2) | Number Of Cores (Core) | AWG size 1 (AWG) | Rated Voltage 1 | Shield 1 | Sheath (outer coating) color | Grounding Wire | Overall Length 1 (m) | Properties 1 | Finished outer diameter (mm) | Representative Standard | Sheath (outer coating) material | Insulation body materials | Power supply/signal | Number of Contacts (core) | Conductor Cross-Sectional Area (mm2) | AWG Size (AWG) | Rated Voltage | Safety Standards | Overall Length (m) | Finish Outer Diameter (mm) | Other Properties | Other properties |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 870.26 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 12 | 13.2 | - | Flame Retardancy | ||
MYR 942.78 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 13 | 13.2 | - | Flame Retardancy | ||
MYR 1,015.31 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 2 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 14 | 13.2 | - | Flame Retardancy | ||
MYR 8,207.15 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 92 | 13.9 | - | Flame Retardancy | ||
MYR 8,296.38 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 93 | 13.9 | - | Flame Retardancy | ||
MYR 8,385.57 | 1 Piece(s) | 12 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 3 | [5.1 to 5.4] 5.26 | 10 | - | PSE / UL RECOGNIZED / UL LISTED / CE / CCC | 94 | 13.9 | - | Flame Retardancy |


TAIYO CABLETEC
Standard Price : MYR 118.65-
Days to Ship : 6 Day(s) or more

TAIYO CABLETEC
Standard Price : MYR 48.32-
Days to Ship : 6 Day(s) or more

TAIYO CABLETEC
Standard Price : MYR 1,845.83-
Days to Ship : 7 Day(s) or more

TAIYO CABLETEC
Standard Price : MYR 542.11-
Days to Ship : 6 Day(s) or more

CHUGOKUDENSEN
Standard Price : MYR 31.07-
Days to Ship : 4 Day(s) or more

TAIYO CABLETEC
Standard Price : MYR 40.36-
Days to Ship : 6 Day(s) or more

TAIYO CABLETEC
Standard Price : MYR 32.52-
Days to Ship : 6 Day(s) or more



MISUMI
Standard Price : MYR 46.83-
Days to Ship : 4 Day(s) or more

MISUMI
Standard Price : MYR 35.15-
Days to Ship : 4 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy