(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

3-Port Air Operated Valve SYJA300 Series (SYJA312-M3-F)

3-Port Air Operated Valve SYJA300 Series SYJA312-M3-F

·SYJA300 Series 3-port air operated valve.

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.
  • CAD data is not available for some model numbers.

PDF

Part Number

Configured Part Number is shown.

SYJA312-M3-F

Drawing

Direct piping type: SYJA3□2-M3 (-F)

Drawing 1 of 3-port air operated valve, SYJA300 Series

Base piping type: SYJA3□4-M5

Drawing 2 of 3-port air operated valve, SYJA300 Series

Product Specifications

Part number display method

Part number display method for 3-port air operated valve, SYJA300 Series

Specifications

Operating fluidAir
Operating pressure range MPa+0.15 to +0.7
^*1) Pilot pressure range MPaOperating pressure ~ +0.7
Ambient and operating fluid temperatures °C-10 to +60 (No freezing.)
LubricationNot required
Mounting orientationFree
^*2) Impact resistance / vibration resistance m/s^2150/30

*1) Due to the structure, this product operates when return pressure is provided from the supply port (port 1 (P)); therefore, be sure to supply pressure in the working pressure range to the supply port.
*2) Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve with pilot signal ON and OFF (once for each condition). (Initial value)
Vibration resistance: No malfunction when tested under 45 to 2,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)

Flow Rate Characteristics / Weight List

Valve part numberSwitching methodPipe connection diameterFlow rate characteristicsPilot connection port diameterMass gEffective Cross-Sectional Area
mm^2
1→2 (P→A)2→3 (A→R)
C [dm^3/(s*bar)]bCvC [dm^3/(s*bar)]bCv
Direct piping typeSYJA312-M3N.C.M3 × 0.5M3 × 0.5180.9
SYJA322-M3N.O.
Base piping type
(With sub-plate)
SYJA314-M5N.C.M5 × 0.80.410.180.0860.350.330.08639 (No sub-plate 18)
SYJA324-M5N.O.0.360.310.0890.360.310.089

*) The part numbers of the base piping type without sub-plate are SYJA314 and SYJA324.

Part Number
SYJA312-M3-F
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPlumbing Thread Nominal Switching Type Connection Type Bracket Piping Piping Connection Port Diameter

MYR 192.50

1 Piece(s) 3 Day(s) M3Normally ClosedMYesBody Ported Type-

Loading...

  1. 1
 

Basic Information

Applicable Fluid Air Type Air Operating Type Operating Environment Standard
Operating Temperature Range(°C) -10::60

Please check the type/dimensions/specifications of the part SYJA312-M3-F in the 3-Port Air Operated Valve SYJA300 Series series.

Products like this...

Part Number
SYJA312-M3
SYJA314
SYJA314-M5
SYJA322-M3
SYJA322-M3-F
SYJA324
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPlumbing Thread Nominal Switching Type Connection Type Bracket Piping Piping Connection Port Diameter

MYR 184.45

1 Piece(s) 43 Day(s) M3Normally ClosedMNoneBody Ported Type-

MYR 230.87

1 Piece(s) 21 Day(s) -Normally Closed-NoneBase Mounted TypeNo sub-plate

MYR 220.16

1 Piece(s) 14 Day(s) or more M5Normally ClosedMNoneBase Mounted TypeSub-plate with M5 ports included

MYR 181.97

1 Piece(s) 14 Day(s) or more M3Normally OpenMNoneBody Ported Type-

MYR 192.50

1 Piece(s) 3 Day(s) M3Normally OpenMYesBody Ported Type-

MYR 230.87

1 Piece(s) 21 Day(s) -Normally Open-NoneBase Mounted TypeNo sub-plate