(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Select a digital flow switch for energy saving management.
[Features]
· Fluid: dry air, N2, Ar, CO2
・ A wide range of flow rates can be measured with 1 unit
· Range ability: 100: 1, minimum setting unit 0.01 L/min.
・ Improved moisture resistance and contaminant resistance
· Compact/lightweight, weight: 27.3% reduction (55 g to 40 g)
· Low current consumption: 35 mA or less
・ Display inversion function
· Piping variations
・ Integrated flow rate control valve
・ Flow rate with digital display「visualization」
・ It can be switched according to the operating fluid used
・ Delay time setting
・ Lubrication-free
・ Analog free span function
・ Adopted analog voltage output switching function
· Power supply voltage: supports 12 to 24 V
Part Number
Configured Part Number is shown.
PF2M711S-C8-CN-M



*2 When using the accumulated value hold function, calculate the lifespan from the usage conditions and use within the lifespan. The limit of the number of accesses of the storage element (electronic component) is 3.7 million times. When energized for 24 hours, the lifespan is as follows.

| Part number | A | P |
|---|---|---|
| PF2M701/702/705/710-C4 | 59.1 | ø2.8 depth 8.4 |
| PF2M701/702/705/710/725/750-C6 | 59.9 | ø2.8 depth 8.4 |
| PF2M711-C8 | 68 | ø2.8 depth 6.2 |
| Part number | A | B | P |
|---|---|---|---|
| PF2M701/702/705/710/725/750-01 | 66 | 14 | ø2.8 depth 8.4 |
| PF2M701/702/705/710/725/750-N1 | 68 | 14 | ø2.8 depth 8.4 |
| PF2M701/702/705/710/725/750-F1 | 70 | 14 | ø2.8 depth 8.4 |
| PF2M711-02 | 70 | 17 | ø2.8 depth 6.2 |
| PF2M711-N2 | 70 | 17 | ø2.8 depth 6.2 |
| PF2M711-F2 | 78 | 21 | ø2.8 depth 6.2 |
| Part Number |
|---|
| PF2M711S-C8-CN-M |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Fluid Type | Flow Rate Range (Max. Value) (L/min) | Sensor, Monitor Structure | Output Method | Analog Output Specification | Pipe Port Type | Number of Input Points | Number of Output Points | Analog Voltage Output (V) | Analog Current Output (mA) | Power Supply Type | Power Supply Voltage (V) | Connecting Tube Diameter | Liquid contact parts material | Acquired Standards | Protection Structure | Unit Specifications | Bracket | Lead Wire | Flow rate control valve | Rated Pressure Range | Rating Flow Range (L/min) | Details Type | Option | Calibration Certificate | Number of stations |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 822.18 | 1 Piece(s) | 27 Day(s) or more | [Flow Switches] Flow Switch | Air / Nitrogen Gas / Carbonic Acid Gas / Argon | 100~Less than 500 | [Integrated Type] Display Integrated | NPN Open Collector / Analog / Pulse | Voltage | [One-Touch Couplings] One-Touch Couplings | 1 | 2 | [DC1-5V] 1-5V | - | DC | [24] 24±10% | [8] 8 | Resin + Metal | CE | IP40 | SI unit fixed | None | Without lead with connector | Available | -70 kPa to 750 kPa | 1 to 100 | - | None | None | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.