(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[10-Series, Clean Series]
· Suitable for clean environment
· It prevents dust generation in the cleanroom
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Status at Power Off | Plumbing Thread Nominal | Applicable Cylinder Dia. (Ø) | Pressure Rating (MPa) | CV Value | Pilot Air Supply | Coil specifications | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Valve specifications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 553.28 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY3000 | ||
MYR 474.45 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 414.89 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 482.28 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 485.84 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | Grommet Lead Length 600 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 408.26 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 419.20 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 485.84 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | L-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 422.82 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 490.15 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 427.08 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 490.15 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/8 | 63 or less | 0.15 to 0.7 | 0.24 | Internal | Standard | M plug connector without lead wire | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 454.33 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | -0.1 to 0.7 | - | External | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 675.06 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY3000 | ||
MYR 533.16 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 533.16 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 600.54 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/8 | - | 0.1 to 0.7 | 0.24 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 592.62 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/8 | - | 0.1 to 0.7 | 0.24 | Internal | Standard | L-type plug connector without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY3000 | ||
MYR 541.09 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | L-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 548.97 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 607.34 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/8 | - | 0.1 to 0.7 | 0.24 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 616.35 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/8 | - | 0.1 to 0.7 | 0.24 | Internal | Standard | L plug connector with lead (length 300 mm) | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 607.34 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/8 | - | 0.1 to 0.7 | 0.24 | Internal | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 610.16 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Closed Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | - | Internal | Standard | L-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 695.18 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Closed Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/8 | - | 0.2 to 0.7 | 0.18 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY3000 | ||
MYR 470.14 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 541.09 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 538.07 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | DIN terminal with connector | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 509.53 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 580.48 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 430.70 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 501.65 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 438.57 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 509.53 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 442.89 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 513.84 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | Grommet Lead Wire Length 300 mm | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 509.53 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 435.01 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L-type plug connector without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 442.89 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 446.45 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 517.40 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | 0.64 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 438.57 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 442.89 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | M-type plug connector without connector | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 446.45 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 619.92 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 698.75 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 769.70 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | 0.64 | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 706.62 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | DIN terminal with connector | Push-turn locking hand-operated type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 556.79 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 627.74 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | 0.64 | Internal | Standard | Grommet Lead Wire Length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 643.55 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | 0.64 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 556.79 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | - | Internal | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | 10-SY5000 | ||
MYR 643.55 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | 0.64 | Internal | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 675.06 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | -0.1 to 0.7 | 0.64 | External | Standard | M plug connector with lead (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 848.53 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Closed Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | 0.5 | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 643.55 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Closed Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | - | Internal | Standard | Grommet Lead Wire Length 300 mm | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 722.38 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Closed Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | 0.5 | Internal | Standard | L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 848.53 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Exhaust Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | 0.44 | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY5000 | ||
MYR 659.36 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Pressure Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | - | Internal | Standard | Grommet Lead Length 600 mm | Non-locking, push type | With indicator light and surge voltage suppressor | 10-SY5000 | ||
MYR 541.09 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | - | Internal | Standard | DIN terminal with connector | Non-locking, push type | With indicator light / surge voltage suppressor (Non-polarized type) | 10-SY7000 |
Loading...
| Number of Ports | 5-Port Valve | Specifications | Lubrication Free / Clean Room | Plumbing | Sub-Base Plumbing |
|---|---|---|---|---|---|
| Type | Solenoid Valves | Driving Type | Pilot Type Spool | Seal Type | Soft Seal |
| CE compliant | Non-compliant | Type | Clean series (Relief type) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy