[Rechargeable battery compatible series]
Copper (Cu) and zinc (Zn) materials are not used in the rechargeable battery manufacturing process to reduce product defects.
Some aluminum alloys and die-cast aluminum materials contain small amounts of copper (Cu) and zinc (Zn) as additive elements.
Electrolytic nickel plating and zinc plating with copper base are not used. (Electroless nickel plating is used.)
It uses low dew point compatible grease, -70°C compatible, improved performance in low dew point environment.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Application | Switching Type | Voltage | Number of Solenoids | Mounting Orientation | Pipe Port Type | Status at Power Off | Plumbing Thread Nominal | Applicable Cylinder Dia. (Ø) | Pressure Rating (MPa) | Pilot Air Supply | Coil specifications | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Valve specifications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 467.12 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 474.17 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | Internal | Standard | DIN terminal (with connector) | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 435.61 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 521.86 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 442.66 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | DIN terminal (with connector) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 363.78 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 375.82 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | L plug connector (with lead), lead length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 438.01 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | [Single] Single | Direct | [Rc (R)] Rc | Self-Recovery (Pressure Differential Return) | 1/4 | 80 or Less | 0.15 to 0.7 | Internal | Standard | L plug connector (with lead), lead length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 371.36 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | M plug connector (with lead), lead length 300 mm | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 393.93 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | DIN (EN175301-803) terminal (with connector) | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 442.66 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | DIN (EN175301-803) terminal (with connector) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 557.31 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 640.88 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 633.77 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 704.73 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 470.65 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | Internal | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 486.36 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | Internal | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 569.20 | 1 Piece(s) | 27 Day(s) or more | Single Use | 2-Position Exhaust | AC100V | Double | Direct | [Rc (R)] Rc | Self-Retaining | 1/4 | - | 0.1 to 0.7 | Internal | Standard | L plug connector (with lead), lead length 300 mm | Non-locking, push type | With indicator light and surge voltage suppressor | SY5000 | ||
MYR 544.64 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Closed Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | Internal | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 616.58 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Closed Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | Internal | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 577.32 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Closed Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | -0.1 to 0.7 | External | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 648.28 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Closed Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | -0.1 to 0.7 | External | Standard | Grommet lead wire length: 300 mm | Non-locking, push type | Without indicator light / surge voltage suppressor | SY5000 | ||
MYR 715.02 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Exhaust Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 785.97 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Exhaust Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 785.97 | 1 Piece(s) | 27 Day(s) or more | Single Use | 3-Position Pressure Center | AC100V | Double | Direct | [Rc (R)] Rc | Self-Recovery (Spring Return) | 1/4 | - | 0.2 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | SY5000 | ||
MYR 407.53 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | [Single] Single | Manifold Base | - | Self-Recovery (Pressure Differential Return) | - | - | 0.15 to 0.7 | Internal | Standard | L plug connector (without connector) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | SY7000 | ||
MYR 592.44 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 2-Position Exhaust | AC100V | Double | Manifold Base | - | Self-Retaining | - | - | 0.1 to 0.7 | Internal | Standard | DIN terminal (with connector) | Non-locking, push type | Without indicator light / surge voltage suppressor | SY7000 | ||
MYR 616.12 | 1 Piece(s) | 27 Day(s) or more | Unit for Manifold Mounting | 3-Position Closed Center | AC100V | Double | Manifold Base | - | Self-Recovery (Spring Return) | - | - | 0.2 to 0.7 | Internal | Standard | L plug connector (without connector) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | SY7000 |
Loading...
| Number of Ports | 5-Port Valve | Specifications | Lubrication Free | Plumbing | Sub-Base Plumbing |
|---|---|---|---|---|---|
| Type | Solenoid Valves | Driving Type | Pilot Type Spool | Seal Type | Soft Seal |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy