(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Current output 2SA
Voltage output 2SV
- Analogue output 0 to 10 V, adjustable switching outputs 2x PNP or 2x NPN
- Analogue output 4 to 20 mA, adjustable switching outputs 2x PNP or 2x NPN
- Freely selectable pulse output for consumption measurement
- Analogue filter for setting the risetime
- Digital filter for smoothing the display values
| Type | -10U | -50U | -200U | -600U | -1000U |
|---|---|---|---|---|---|
| General | |||||
| Certification | RCM trademark | ||||
| c UL us - Recognized (OL) | |||||
| Certificate issuing authority | UL E322346 | ||||
| CE mark (see declaration of conformity) | To EU EMC Directive | ||||
| In accordance with EU Explosion Protection Directive (ATEX) | |||||
| To EU RoHS Directive | |||||
| Note on materials | RoHS-compliant | ||||
| Input signal/measuring element | |||||
| Measured variable | Flow rate, consumption | ||||
| Direction of flow | Unidirectional P1 > P2 | ||||
| Measuring principle | Thermal | ||||
| Flow measuring range [l/min] | 0.1 to 10 | 0.5 to 50 | 2 to 200 | 6 to 600 | 10 to 1000 |
| Operating pressure [bar] | 0 to 10 | ||||
| Nominal pressure [bar] | 6 | ||||
| Operating medium | Compressed air in accordance with ISO 8573-1:2010 [6:4:4] | Compressed air in accordance with ISO 8573-1:2010 [7:4:4] | |||
| Nitrogen | Nitrogen | ||||
| Temperature of medium [℃] | 0 to 50 | ||||
| Ambient temperature [℃] | 0 to 50 | ||||
| Nominal temperature [℃] | 23 | ||||
| Electrical data | |||||
| Type | -10U | -50U | -200U | -600U | -1000U |
| Output, general | |||||
| Accuracy of flow rate values | +/- (3% o.m.v. + 0.3% FS) | ||||
| Repetition accuracy [%] of zero point ±FS | 0.2 | ||||
| Repetition accuracy of margin ±FS [%] | 0.8 | ||||
| Temperature coefficient [%] of margin ±FS/K | ≤0.1 | ||||
| Pressure dependence [%] of margin ±FS/bar | 0.5 | ||||
| Switching output | |||||
| Switching output | 2x PNP or 2x NPN, adjustable | ||||
| Switching function | Window comparator or threshold value comparator, adjustable | ||||
| Switching element function | N/C or N/O contact, adjustable | ||||
| Switch-on time | Adjustable (factory setting: approx. 80 ms) | ||||
| Switch-off time | Adjustable (factory setting: approx. 80 ms) | ||||
| Max. output current [mA] | ≤100 | ||||
| Voltage drop [V] | Max. 1.5 | ||||
| Inductive protective circuit | Adapted to MZ, MY, ME coils | ||||
| Analogue output | |||||
| Characteristic flow rate curve [l/min] | 0 to 10 | 0 to 50 | 0 to 200 | 0 to 600 | 0 to 1000 |
| Output characteristic curve [mA] for current | 4 to 20 | ||||
| Output characteristic curve [V] for voltage | 0 to 10 | ||||
| Rise time [ms] | Possible settings: 15, 30, 60 (factory setting), 125, 250, 500, 999 | ||||
| Max. load resistance [ohms] at current output | 500 | ||||
| Min. load resistance [kohms] at voltage output | 10 | ||||
| Output, additional data | |||||
| Protection against short circuit | Yes | ||||
| Protection against overloading | Yes | ||||
| Electronic components | |||||
| Operating voltage range DC [v] | 15 to 30 | ||||
| Protection against polarity reversal | For all electrical connections | ||||
| Electromechanical components | |||||
| Electrical connection | Straight plug, M12x1, 5-pin | ||||
| Max. length of connecting cable [m] | <10 | ||||
| Part Number |
|---|
| SFAB-600U-HQ10-2SV-M12 |
| SFAB-600U-WQ10-2SV-M12 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Operating Temperature Range (°C) | IP | Pneumatic connection | Display type | Switching output | Switching element function | Max. output current (mA) | Pressure drop | Manufacturer part # | Weight (g) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 5,910.51 | 1 Piece(s) | Quote | 0~50 | IP65 | QS-10 | Illuminated LCD blue | 2xPNP or 2xNPN switchable | N/C contact, N/O contact | ≤ 100 | < 100 mbar | 565402 | 600 | ||
MYR 5,960.25 | 1 Piece(s) | Quote | - | - | For pneumatic tubing outside diameter 10 mm | Illuminated LCD, multi-color | 2 x PNP or 2 x NPN switchable | N/C contact/N/O contact switchable | 100 | 100 mbar | 565404 | - |
Loading...
| Housing material | PA-reinforced | Flow measuring range start value(l/min) | 6 | Flow measuring range end value(l/min) | 600 |
|---|---|---|---|---|---|
| Min. Operating pressure(bar) | 0 | Max. Operating pressure(bar) | 10 | Min. Temperature of medium(°C) | 0 |
| Max. Temperature of medium(°C) | 50 | Nominal temperature(°C) | 23 | IP rating | IP65 |
| DC operating voltage range(V) | 15-30 | Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4], Nitrogen | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy