[Features]
・ Low power consumption 0.75 W. (Current: 31 mA 24 V DC)
・ Body width 10 mm.
・ High reliability.
· Suitable for vacuum applications.
・ Suitable for use in copper-free and fluorine-free applications.
· Attractive design with bright color tones.
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Application | Switching Type | Voltage | Mounting Orientation | Pipe Port Type | Plumbing Thread Nominal | Plumbing | Driving Type | Pilot Air Supply | Manual Switch | Lead wire electrical entry | Manual | Indicator light / Surge voltage suppressor | Bracket | CE compliant | Piping specifications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 162.65 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Linear Motion Poppet | Internal | Non-Locking | - | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
MYR 181.33 | 1 Piece(s) | 23 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | - | Non-locking, push type | Without indicator light / surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Lock | - | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
MYR 158.28 | 1 Piece(s) | 23 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm)$L plug connector with lead (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking screwdriver-operated type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 162.59 | 1 Piece(s) | 23 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | - | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 166.21 | 1 Piece(s) | 23 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | - | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
MYR 186.54 | 1 Piece(s) | 23 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug without connector | Push-turn locking screwdriver-operated type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | With surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 217.74 | 1 Piece(s) | 14 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
MYR 182.58 | 1 Piece(s) | 3 Day(s) | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug without connector | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 186.10 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Lock | L plug without connector | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
MYR 162.65 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 178.35 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug without connector | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug without connector | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug without connector | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With surge voltage suppressor | - | Non-compliant | - | ||
MYR 194.10 | 1 Piece(s) | 23 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking screwdriver-operated type | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
MYR 296.78 | 1 Piece(s) | 46 Day(s) | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 166.21 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm)$L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 197.73 | 1 Piece(s) | 14 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | L plug connector with lead wire (length 300 mm)$L plug connector with lead (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 213.42 | 1 Piece(s) | 14 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | L plug connector with lead wire (length 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
MYR 233.52 | 1 Piece(s) | 21 Day(s) | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
MYR 170.52 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 283.40 | 1 Piece(s) | 21 Day(s) | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | L plug connector with lead wire (length 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
MYR 189.79 | 1 Piece(s) | 23 Day(s) or more | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector without lead wire | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
MYR 158.28 | 1 Piece(s) | 23 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector without lead wire | Push-turn locking hand-operated type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | M plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | M plug connector without lead wire | Non-locking, push type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | M plug without connector | Non-locking, push type | Without indicator light / surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Direct Plumbing | Linear Motion Poppet | Internal | Non-Locking | M plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
MYR 186.23 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Lock | M plug without connector | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | CE compliant product | - | ||
MYR 162.65 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
MYR 178.35 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Non-Locking | M plug without connector | Non-locking, push type | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | M | M3 | Sub-Base Plumbing | Linear Motion Poppet | Internal | Lock | M plug without connector | Locking type, screwdriver operated | With indicator light and surge voltage suppressor | - | CE compliant product | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug without connector | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug without connector | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug without connector | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Push-turn locking screwdriver-operated type | With surge voltage suppressor | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Locking type, screwdriver operated | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 289.15 | 1 Piece(s) | 21 Day(s) | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Push-turn locking screwdriver-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
- | 1 Piece(s) | Quote | Single Use | 2-Position Normally Closed | DC24V | Direct | M | M3 | Sub-Base Plumbing | Linear Motion Spool | - | Lock | M plug connector with lead wire (length: 300 mm) | Push-turn locking hand-operated type | With indicator light and surge voltage suppressor (non-polar type) | - | Non-compliant | - | ||
MYR 166.21 | 1 Piece(s) | 14 Day(s) or more | Unit for Manifold Mounting | 2-Position Normally Closed | DC24V | Manifold Base | - | - | Sub-Base Plumbing | Linear Motion Spool | - | Non-Locking | M plug connector with lead wire (length: 300 mm) | Non-locking, push type | With indicator light and surge voltage suppressor | - | Non-compliant | - |
Loading...
| Number of Ports | 3-Port Valve | Number of Solenoids | Single | Specifications | Lubrication Free |
|---|---|---|---|---|---|
| Status at Power Off | Self-Recovery (Spring Return) | Type | Solenoid Valves | Pressure Rating(MPa) | 0 to 0.7 |
| Seal Type | Soft Seal | CV Value | 0.012 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy