(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[10-/11-Series, Clean Series]
・ It is suitable for clean environment.
・ It prevents dust generation in the cleanroom.
[20-Series Copper/Fluorine-Free Specifications]
・ Suitable for use in environments that dislike copper and fluorine materials.
・ External dimensions are the same as standard products.
[21/22-Series, copper / fluorine / silicone-free + low dust generation]
・ It supports environments with restrictions on copper-based, fluorine-based, and silicone-based materials.
・ The structure is the same as the Clean Series (Grease and packaging are different from the Clean Series. )
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Environment, Applications | Operating Temperature (°C) | Operating Pressure (MPa) | Specifications | Body Options | Auto Switches | Lead Wire | The number of the switches | Type of Mount Support | Connector type | Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 25 | 15 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 15 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 20 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 20 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 25 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 25 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 30 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 30 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
MYR 291.80 | 1 Piece(s) | 21 Day(s) | 25 | 35 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
MYR 302.38 | 1 Piece(s) | 21 Day(s) | 25 | 35 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | - | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | - | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 45 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 45 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 50 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Standard (rod-end female thread) | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 25 | 50 | Clean Room | -10~70 | 0.05 to 1 | Without magnet | Male rod end | - | - | - | Through-hole (standard) | - | Clean Series (relief type) | ||
- | 1 Piece(s) | Quote | 12 | 2 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 254.28 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 519.57 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 519.57 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 547.40 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9PV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 261.32 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Male rod end | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 407.90 | 1 Piece(s) | 21 Day(s) | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9NV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9NV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 5 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9NV | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 275.45 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 414.93 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 442.77 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 540.32 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BWV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NV | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NWV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 282.52 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Male rod end | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 421.58 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 449.83 | 1 Piece(s) | 21 Day(s) | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BWV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9NV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 10 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9NV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 306.80 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 474.10 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 564.60 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 435.70 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9N | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 439.23 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9N | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 585.77 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9NW | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 313.85 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Male rod end | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 481.17 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | A93 | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 543.85 | 1 Piece(s) | 21 Day(s) | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9B | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9B | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 15 | Clean Room | - | 0.07 to 1 | Built-in magnet | Male rod end | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 338.15 | 1 Piece(s) | 21 Day(s) | 12 | 20 | Clean Room | -10~70 | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | Without auto switch | - | - | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
MYR 505.45 | 1 Piece(s) | 21 Day(s) | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93 | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 3 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | A93V | 0.5 | 1 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9B | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9BV | 3 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) | ||
- | 1 Piece(s) | Quote | 12 | 20 | Clean Room | - | 0.07 to 1 | Built-in magnet | Standard (rod-end female thread) | M9N | 0.5 | 2 | Through-hole (standard) | - | Clean Series (vacuum type) |
Loading...
| Rod Operation Method | Single Rods | Main Body Shape | Plate Cylinder | Cylinder Operation Method | Double Acting |
|---|---|---|---|---|---|
| Additional Function | Standard | End Locking | No | Valves | No |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy