[Features]
・ It can be mounted on the vacuum ejector system ZX and ZR Series.
・ With suction filter.
Part Number
Configured Part Number is shown.
ISE2-01-55L
Grommet type / ZSE2-0X□-15

Connector type / ZSE2-0X□-15C







| Model | ZSE2 | ISE2L | ISE2 | |
|---|---|---|---|---|
| For vacuum | For low pressure | For positive pressure | ||
| Rated pressure range / set pressure range | 0 to -101 kPa | 0 to 100 kPa | 0 to lMPa | |
| Pressure resistance | 500 kPa | 1.5 MPa | ||
| Compatible fluid | Air / non-corrosive gas / non-flammable gas | |||
| Power supply voltage | 12 to 24 V DC ±10%, ripple (p-p) 10% or less (with power supply polarity protection) | |||
| Current consumption | 17 mA or less (At 24 V DC ON) | |||
| Response time | 5 ms or less | |||
| Repeatability | ±1% F.S. or less | |||
| Environmental resistance | Protective structure | IP40 | ||
| Operating temperature range | During operation: 0 to 60°C, when stored: -10 to 60°C (Do not condense or freeze) | |||
| Operating humidity range | During operation, storage: 35 to 85% RH (No condensation) | |||
| Temperature characteristics (reference: 25°C) | ±3% F.S. or less | |||
| Withstand Voltage | 1,000 V AC for 1 minute between live parts and housing | |||
| Insulation resistance | 50 MΩ or more (with 500 V DC insulation resistance tester) between live parts and housing | |||
| Pipe connection diameter | 01:R1/8, M5 × 0.8 T1:NPTF1/8, M5 × 0.8 0X: With suction filter (ZX ejector mounted type), 0R: Base mount type (ZR ejector mounted type) | |||
| Weight | 35 g (Including lead 0.6 m) | |||
| Lead | Grommet type | Oil-resistant vinyl cabtire cable, 3 cores ø3.4, conductor cross-sectional area: 0.2 mm^2, insulator outer diameter: 1.1 mm | ||
| Connector type | Heat-resistant vinyl cable, 3-cable, conductor cross-sectional area: 0.31 mm^2, insulator outer diameter: 1.55 mm | |||
| Standards | CE, RoHS | |||
| Model | -15 | -55 |
|---|---|---|
| Switch output | NPN open collector, 30 V, 80 mA or less | PNP open collector, 80 mA or less |
| Residual voltage | 1 V or less (At 80 mA) | |
| Number of outputs | 1 point | |
| Hysteresis | 3% F.S. or less (fixed) | |
| Operation indicator light | ON: when output is on (Red) | |
| Trimmer rotation angle for pressure setting | 200° | |
| Part Number |
|---|
| ISE2-01-55L |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Fluid Type | Sensor, Monitor Structure | Output Method | Pipe Port Type | Plumbing Thread Type | Plumbing Thread Nominal | Fluid Characteristics | Pressure Resistant (MPa) | Operating Temperature Range (°C) | Operating Humidity Range (%) | Number of Input Points | Number of Output Points | Power Supply Type | Power Supply Voltage (V) | Acquired Standards | Protection Structure | Application | Rated Pressure Range | Details Type | Wiring Specifications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 554.04 | 1 Piece(s) | 14 Day(s) or more | Pressure Switch | Air | [Separate Type, Connector Connection] Separate Type, Connector Joint | PNP Open Collector | Male Thread, Female Thread | [Rc (R)] R | [1/8] 1/8 | Noncorrosive / Incombustible | 1.5 | 0~60 | 35~85 | 1 | 1 | DC | [12~24] 12 to 24 ±10% | CE | IP40 | For positive pressure | 0 to 1 MPa | - | Grommet type (lead wire: 3 m) |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy