(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[Features]
· Thin, low center of gravity
The offset structure of the belt drive and sleeve allows for a thinner table height.
Air cylinder-like end-to-end control (up to 12 intermediate stop positions possible)
Easy position setting with numerical input
Installation is compatible with the previous product E-MY2 series.
Can be combined with various guides
· Motor mounting position: selectable for top/bottom and left/right
· Non-contact auto switch can be installed for limit detection and intermediate signal detection!
Part Number
Configured Part Number is shown.
| Part Number | Minimum order quantity | Volume Discount | Days to Ship | Stroke (mm) | Max. Transportable Mass Range (Horizontal) (kg) | Max. Transportable Mass (Horizontal) (kg) | I/O Module | Max. Thrust Force Range (N) | Brake | Max. Thrust Force (N) | Size | Motor mounting position | Step data (points) | Actuator/cable type | Actuator cable length (m) | Controller/driver type | I/O cable length / communication plug (m) | Controller/driver mounting method | Stroke adjustment unit |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 Piece(s) | Quote | 350 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 350 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 350 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Standard cable | 5 | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | PROFINET | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 64 | Robot cable | 3 | JXCP1 (PROFINET direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP1 (programless type) | Without cable (without communication plug connector) | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | Not Provided | 0~100 | Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | Motor side only | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 400 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | Ethernet | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 64 | Robot cable | 5 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Robot cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Robot cable | 20 | LECP2 (programless type (with stroke learning function)) | 5 | DIN rail mounting type | Both sides | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 500 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 3 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 550 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 600 | 5.1~10.0 | 6 | PROFINET | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 64 | Robot cable | 15 | JXCP1 (PROFINET direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 600 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 3 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 600 | 5.1~10.0 | 6 | Not Provided | 0~100 | Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Robot cable | 3 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP1 (programless type) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | PNP | 0~100 | Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 700 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 800 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 800 | 5.1~10.0 | 6 | NPN | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 14 | Standard cable | 5 | LECP1 (programless type) | Without cable (without communication plug connector) | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 800 | 5.1~10.0 | 6 | Not Provided | 0~100 | Not Provided | 58.8 | 25 | Bottom (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 900 | 5.1~10.0 | 6 | Ethernet | 0~100 | Provided | 58.8 | 25 | Bottom (Reverse Parallel) | 64 | Robot cable | 5 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 100 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Robot cable | 5 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Robot cable | 5 | LECP1 (programless type) | 5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Robot cable | 5 | LECP1 (programless type) | 5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Robot cable | 5 | LECP2 (programless type (with stroke learning function)) | 5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Ethernet | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Robot cable | 10 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Ethernet | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Robot cable | 10 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Standard cable | 1.5 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 1.5 | JXCP1 (PROFINET direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Standard cable | 3 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Standard cable | 5 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 5 | JXCP1 (PROFINET direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 5 | JXCP1 (PROFINET direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP1 (programless type) | Without cable (without communication plug connector) | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP1 (programless type) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | NPN | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1000 | 10.1~20.0 | 11 | Not Provided | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 100 | 10.1~20.0 | 11 | EtherCAT | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 5 | JXCE1 (EtherCAT (R) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 100 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 100 | 10.1~20.0 | 11 | NPN | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | End side only | ||
| 1 Piece(s) | Quote | 100 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 1100 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1100 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Robot cable | 3 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1100 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Robot cable | 3 | LECP1 (programless type) | Without cable (without communication plug connector) | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1100 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Robot cable | 3 | LECP2 (programless type (with stroke learning function)) | Without cable (without communication plug connector) | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1100 | 10.1~20.0 | 11 | Ethernet | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 3 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | Ethernet | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Robot cable | 5 | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | Ethernet | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Without cable | Without cable | JXC91 (EtherNet/IP (TM) direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1200 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Motor side only | ||
| 1 Piece(s) | Quote | 1300 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1300 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Standard cable | 1.5 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1300 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 5 | JXCP1 (PROFINET direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1300 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 1300 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | Both sides | ||
| 1 Piece(s) | Quote | 1400 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1400 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Standard cable | 3 | JXCP1 (PROFINET direct input type) | No plug connector | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1400 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1400 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Robot cable | 5 | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | PROFINET | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 64 | Robot cable | 10 | JXCP1 (PROFINET direct input type) | No plug connector | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | PNP | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP1 (programless type) | 3 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 3 | Screw mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 5 | LECP2 (programless type (with stroke learning function)) | 1.5 | DIN rail mounting type | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | Not Provided | 101~200 | Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | No unit | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | Not Provided | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | - | Without cable | Without cable | Without Controller | Without cable (without communication plug connector) | - | Both sides | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 1.5 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides | ||
| 1 Piece(s) | Quote | 1500 | 10.1~20.0 | 11 | NPN | 101~200 | Not Provided | 107.8 | 32 | Top (Reverse Parallel) | 14 | Standard cable | 3 | LECP2 (programless type (with stroke learning function)) | 1.5 | Screw mounting type | Both sides |
Loading...
| Type | Slider | Drive Method | Belt | Main Body, Peripheral Components | Main Body |
|---|---|---|---|---|---|
| Lead(mm) | 48 Equivalent | Guide | Provided | Input Power Supply | DC24V |
| Position Detection | Incremental | Table Length L1(mm) | 78 | Positioning Repeatability(µm) | ±80 |
| Maximum Velocity(mm/sec) | 1000 | Table Width W1(mm) | 61 | Operating Environment | Standard |
| Noise Filter | Not Provided | Number of Tables | 1 pc. | Operating Temperature Range(°C) | 5::40 |
| Motor type | Step motor (24‑V DC servo) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy