Temperature Controller (Digital Controller) [E5CD/E5CD-B] (E5CD-QX2ABM-001)

Part Number

Configured Part Number is shown.

E5CD-QX2ABM-001

Dimensional Drawing of OMRON Temperature Controllers

Temperature Controllers E5CD

Temperature Controller (Digital Controller) [E5CD/E5CD-B] E5CD Outline Drawing

Temperature Controllers E5CD-B

Temperature Controller (Digital Controller) [E5CD/E5CD-B] E5CD-B Outline Drawing

Specification Table of OMRON Temperature Controllers

Temperature Controllers Names of each part

Temperature Controller (Digital Controller) [E5CD/E5CD-B] Parts Name Diagram

Temperature Controllers Ratings/Performance

Temperature Controllers Rating

Power supply voltagePower supply voltage Type A: AC100-240V 50/60Hz
Power supply voltage Type D: AC24V 50/60Hz /DC24V
Allowable voltage fluctuation range85 to 110% of power supply voltage
Power ConsumptionOption -000 type: 5.2VA or less (AC100-240V), 3.1VA or less (AC24V) / 1.6W or less (DC24V)
Other than the above: 6.5VA or less (AC100-240V), 4.1VA or less (AC24V) / 2.3W or less (DC24V)
Sensor InputTemperature Controllers input
 Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII
 Platinum resistance thermometer: Pt100, JPt100
 Non-contact Temperature Controllers sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C
Analog input
 Current input: 4 to 20mA, 0 to 20mA
 Voltage input: 1 to 5V, 0 to 5V, 0 to 10V
Input impedanceCurrent input: 150 Ω or less, voltage input: 1 MΩ or more
(When connecting to ES2-HB-N/THB-N, use a 1:1 connection.)
Temperature Controllers MethodON/OFF or 2-degree-of-freedom PID (with autotuning)
Temperature Controllers OutputRelay Output1a AC250V 3A (resistive load) Electrical life 100,000 times Minimum applicable load 5V 10mA (reference value)
Voltage output
(for driving SSR)
Output voltage DC12V±20% (PNP) Maximum load current 21mA, with short circuit protection circuit
Linear Current
Output
DC4~20mA/DC0~20mA Load: 500Ω or less Resolution: Approx. 10,000
Auxiliary OutputScore2 points
Output SpecificationsRelay output 1a AC250V, E5CD 3A (resistive load), E5CD-B 2A (resistive load)
Electrical life 100,000 times Minimum applicable load 5V 10mA (reference value)
Event
Input
Score2 points
External contact
input specifications
During contact input: ON: 1kΩ or less OFF: 100kΩ or more
Non-contact input: ON: Residual voltage 1.5V or less OFF: Leakage current 0.1mA or less
Current output: Approx. 7mA (per contact)
Transmission OutputScore1 point (depending on the model): Type with transmission output
Output SpecificationsCurrent output: DC4-20mA Load: 500Ω Resolution: Approx. 10,000
Linear voltage output: DC1-5V Load: 1kΩ or more Resolution: Approx. 10,000
Setting methodDigital setting by front keys
Instruction method11-segment digital display, single-light-emitting display, bar display
character height PV: 14.9 mm, SV: 7.1 mm
Multi-SP function*Up to eight target values ​​(SP0 to SP7) can be stored and selected by event input, key operation, or serial communication
Bank switching functionnone
Other featuresAdaptive Temperature Controllers, automatic filter adjustment function, water-cooled output adjustment function, predictive data (power-on time monitor, ambient temperature monitor, control output ON/OFF count monitor),
parameter mask function, operation specification function at power-on, manual output, heating/cooling control, loop break alarm function, SP lamp, alarm function,
heater break detection function (including SSR failure), 40% AT, 100% AT, manipulated variable limit, input digital filter, robust tuning, PV input correction,
run/stop, protect, square root calculation function, manipulated variable change rate limit, simple calculation, temperature status display function, simple program function,
input moving average, display brightness setting
Ambient Temperature Controllers-10 to +55°C (but no condensation or freezing) / 3-year warranty: -10 to +50°C (but no condensation or freezing) when installed as a standard unit
Ambient humidityRelative humidity 25-85%
Storage temperature-25 to +65°C (but no condensation or freezing)
AltitudeUnder 2,000m
Recommended fuseT2A, AC250V Time-lag low breaking capacity
Installation environmentOvervoltage Category II, Pollution Degree 2 (EN/IEC/UL 61010-1)

* If you select from event input, the maximum number of target values ​​is 4.

Temperature Controllers Performance

Indication accuracy
(ambient temperature 23℃)
Thermocouple: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit or less *1
Platinum resistance thermometer: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit or less
Analog input: ±0.2%FS ±1 digit or less
CT input: ±5%FS ±1 digit or less
Transmission Output Accuracy±0.3%FS or less
Temperature Controllers effect *2Thermocouple input (R, S, B, C/W, PLII): (±1% of indicated value or ±10°C, whichever is greater) ±1 digit or less
Other thermocouple input: (±1% of indicated value or ±4°C, whichever is greater) ±1 digit or less *3
Platinum resistance thermometer input: (±1% of indicated value or ±2°C, whichever is greater) ±1 digit or less
Analog input: ±1%FS ±1 digit or less
CT input: ±5%FS ±1 digit or less
Voltage effect *2
Effects of electromagnetic interference
(according to EN 61326-1)
Input Sampling Period50ms
Adjustment SensitivityTemperature input: 0.1 to 999.9°C/°F (in 0.1°C/°F increments)
Analog input: 0.01 to 99.99%FS (in 0.01%FS increments)
Proportional band (P)Temperature Controllers input: 0.1 to 999.9°C/°F (in 0.1°C/°F units)
Analog input: 0.1 to 999.9%FS (in 0.1%FS units)
Integration time (I)0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Differential time (D)0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Cooling proportional band (P)Temperature Controllers input: 0.1 to 999.9°C/°F (in 0.1°C/°F units)
Analog input: 0.1 to 999.9%FS (in 0.1%FS units)
Cooling integration time (I)0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Cooling differential time (D)0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4

Dedicated to adaptive control

Proportional band for target response (P)
Temperature Controllers input: 0.1 to 999.9°C/°F (in 0.1°C/°F increments)
Integral time for target response
(I)
0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Derivative time for target response
(D)
0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4

Proportional band for disturbance (P)
Temperature Controllers input: 0.1 to 999.9°C/°F (in 0.1°C/°F increments)
Disturbance
integral time (I)
0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Disturbance
Differential Time (D)
0 to 9999s (in 1s units), 0.0 to 999.9s (in 0.1s units) *4
Control Period0.1, 0.2, 0.5, 1 to 99 s (in 1 s increments)
Manual Reset Value0.0 to 100.0% (in 0.1% increments)
Alarm Setting Range-1999 to 9999 (decimal point position depends on input type)
Effect of signal source resistanceThermocouple: 0.1℃/Ω or less (100Ω or less), Platinum resistance thermometer: 0.1℃/Ω or less (10Ω or less)
Insulation resistance20MΩ or more (500V DC applied)
Withstand voltageAC3,000V 50 or 60Hz 1min (opposite polarity live terminals)
vibrationmalfunction10~55Hz 20m/s2 3 axis direction 10min
Durability10~55Hz 20m/s2 3 axial directions 2h
impactmalfunction100m/s23 axial directions, 3 times each
Durability300m/s23 axial directions, 3 times each
massMain unit: Approx. 120g Mounting adapter: Approx. 10g
Protective structure  Front: IP66, Rear case: IP20, Terminal: IP00
Memory ProtectionNon-volatile memory (number of writes: 1 million times)
Configuration ToolE5CD: CX-Thermo Ver.4.66 or higher
E5CD-B: CX-Thermo Ver.4.67 or higher
Configuration tool portTop of E5CD/E5CD-B: Use the E58-CIFQ2 USB-serial conversion cable to connect to the USB port on the computer. *5
standardCertification StandardscULus: UL 61010-1/CSA C22.2 No.61010-1, Korea Wireless Regulations (Radio Act: KC Mark)
Compliance standardsEN 61010-1 (IEC 61010-1), RCM standard
EMC DirectiveEMI EN 61326-1 *6
Radiated interference field strength EN 55011 Group1 class A
Noise terminal voltage EN 55011 Group1 class A
EMS EN 61326-1 *6
Electrostatic discharge immunity EN 61000-4-2
Electromagnetic field immunity EN 61000-4-3
Burst noise immunity EN 61000-4-4
Conducted interference immunity EN 61000-4-6
Surge immunity EN 61000-4-5
Voltage dip/interruption immunity EN 61000-4-11

*1. K (-200 to 1300°C range), T, N below -100°C, and U, L are within ±2°C ±1 digit. B below 400°C is not specified. B from 400 to 800°C is within ±3°C.
     R, S below 200°C is within ±3°C ±1 digit. C/W is (±0.3% PV or ±3°C, whichever is greater) ±1 digit.
     PLII is (±0.3% PV or ±2°C, whichever is greater) ±1 digit.
*2. Conditions: Ambient Temperature Controllers: -10°C to 23°C to 55°C Voltage range: -15 to +10% of rated voltage
*3. K sensor below -100°C is within ±10°C
*4. The unit depends on the "Integral/Differential time unit" setting.
*5. External serial communication (RS-485) and USB-serial conversion cable communication can be used simultaneously.
*6. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

Part Number
E5CD-QX2ABM-001
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOutput Type Failure Detecting Function Power Supply Voltage
(V)
Control Output 1 Terminal shape Event Input
(Point)
Heater Breakage, SSR Fault Detection Capability Communication Transmission Output

MYR 1,134.51

1 Piece(s) 9 Day(s) or more SSR Drive Output VoltageHeater Breakage / SSR Breakdown100 to 240 ACVoltage output (for SSR drive)Push-in plus terminal block type21 point--

Loading...

  1. 1

Basic Information

Input Method Thermocouple / Platinum temperature measuring resistor / Non-Contact Temperature Sensor / Voltage / Current Control Method ON/OFF Control / PID control with auto tuning Number of Control Points 1
Setting Method Key input Control Output 2 NA Auxiliary Output Points 2 independent
Specifications 48×48 mm Input type Full multi input

Please check the type/dimensions/specifications of the part E5CD-QX2ABM-001 in the Temperature Controller (Digital Controller) [E5CD/E5CD-B] series.

Products like this...

Part Number
E5CD-CX2ABM-000
E5CD-CX2ABM-004
E5CD-CX2D6M-000
E5CD-QX2ABM-002
E5CD-QX2D6M-000
E5CD-QX2D6M-001
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOutput Type Failure Detecting Function Power Supply Voltage
(V)
Control Output 1 Terminal shape Event Input
(Point)
Heater Breakage, SSR Fault Detection Capability Communication Transmission Output

MYR 1,153.29

1 Piece(s) 9 Day(s) or more CurrentNo100 to 240 AC-Push-in plus terminal block type----

MYR 1,637.22

1 Piece(s) 9 Day(s) or more CurrentNo100 to 240 AC-Push-in plus terminal block type2-RS-485-

MYR 1,075.24

1 Piece(s) 9 Day(s) or more CurrentNo24 AC/DC-Screw terminal block type----

MYR 1,542.98

1 Piece(s) 9 Day(s) or more SSR Drive Output VoltageSSR Breakdown / Heater Breakage100 to 240 ACVoltage output (for SSR drive)Push-in plus terminal block type-1 pointRS-485-

MYR 958.57

1 Piece(s) 9 Day(s) or more SSR Drive Output VoltageNo24 AC/DCVoltage output (for SSR drive)Screw terminal block type----

MYR 1,077.97

1 Piece(s) 9 Day(s) or more SSR Drive Output VoltageSSR Breakdown / Heater Breakage24 AC/DCVoltage output (for SSR drive)Screw terminal block type21 point--

Additional Products in this Category

Tech Support