(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Refrigerated air dryer that protects pneumatic equipment from moisture.
[Features]
· Removes the vapor from the moist compressed air delivered by the compressor and prevents it from causing the pneumatic equipment to fail.
· Improved corrosion resistance with the use of stainless-steel heat exchanger.
· Size: 22E, 37E, 55E, 75E.
Part Number
Configured Part Number is shown.
IDFB55E-46-R

Refrigerant R134a (HFC), R407C (HFC) Standard Temperature Air Inlet, IDFB□E Series external appearance
*The external appearance images are representative images.

JIS symbol
Humid, hot air coming into the air dryer is cooled down by a cooler re-heater (heat exchanger). Water condensed at this time is removed from the air by a drain separator (auto drain) and drained out automatically. Air separated from the water is heated by a cooler re-heater (heat exchanger) to approximately ambient temperature to obtain the dried air, which goes through to the outlet side.

Structure Principle Diagram: IDFB22E/IDFB37E/IDFB55E/IDFB75E (Air/Refrigerant Circuit)
| Specifications | Model | ||||||
|---|---|---|---|---|---|---|---|
| Standard-temperature air inlet | |||||||
| IDFB22E | IDFB37E | IDFB55E | IDFB75E | ||||
| Operating range*3 | Applicable fluid | Compressed Air | |||||
| Inlet air temperature (°F [°C]) | 41 to 122 (5 to 50) | ||||||
| Inlet air pressure (psi [MPa]) | 22 (0.15) to 150 (1.0) | ||||||
| Ambient temperature (°F [°C]) | 36 to 104 (2 to 40), Relative humidity of 85% or less | ||||||
| *4 | Air flow capacity SCFM*1, *2) (m3/h [ANR]) | Outlet pressure dew point 37°F (2.8°C) | 107 (182) | 161 (273) | 226 (384) | 300 (510) | |
| Outlet pressure dew point 45°F (7.2°C) | 120 (205) | 173 (294) | 258 (438) | 353 (600) | |||
| Outlet pressure dew point 50°F (10°C) | 130 (221) | 181 (308) | 297 (504) | 406 (690) | |||
| Operating pressure (psi [MPa]) | 100 (0.7) | ||||||
| Inlet air temperature (°F [°C]) | 100 (37.8) | ||||||
| Ambient temperature (°F [°C]) | 100 (37.8) | ||||||
| Electric specifications | Power supply voltage (frequency) | Single-phase 115 V AC (Voltage fluctuation ±10%) 60 Hz | Single-phase 230 V AC (Voltage fluctuation ±10%) 60 Hz | Three-phase 460 V AC (Voltage fluctuation ±10%) 60 Hz | |||
| Operating current*5 (A) | 9 | 4.5 | 5.6 | 3.8 | |||
| Power consumption*5 (W) | 1,000 | 1,270 | 2,400 | ||||
| Applicable circuit breaker capacity*6 (Sensitivity current of 30 mA) (A) | 15 | 10 | |||||
| Condenser | Forced air-cooled | ||||||
| Refrigerant | R134a (HFC) | R407C (HFC) | |||||
| Refrigerant charge (oz [g]) | 18.7 (530) | 25.7 (730) | 15.2 (430) | 20.8 (590) | |||
| Thread symbol and size | Symbol N | NPT 1 (male) | NPT 1 1/2 (male) | NPT 2 (male) | |||
| Symbol Nil | R1 (male) | R1 1/2 (male) | R2 (male) | ||||
| Drain tube outer diameter | Symbol N | 3/8 inch | |||||
| Symbol Nil | 10 mm | ||||||
| Coating color | Urban white 1 | ||||||
| Weight (lbs [kg]) | 119 (54) | 137 (62) | 258 (117) | 271 (123) | |||
| Compliant standards | UL, CSA | ||||||
*1: Indicates the air flow capacity under ANR (atmospheric pressure 68°F (20°C), relative humidity 65%).
*2: Indicates the air flow capacity for each outlet pressure dew point.
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*5: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*6: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
*7: When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.
(Unit: mm)

IDFB22E/IDFB37E dimensional drawing
(Unit: mm)
| Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | P |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IDFB22E | 1 | 11.4 (290) | 30.5 [775] | 24.5 [623] | 5.3 [134] | 15.9 [405] | 27.5 [698] | 3.7 [93] | 1.8 [46] | 1.0 [25] | 0.5 [13] | 12.4 [314] | 3.3 [85] | 23.6 [600] | 13.4 [340] |
| IDFB37E | 1 1/2 | 33.7 [855] | 26.8 [680] |
(Unit: mm)

IDFB55E/IDFB75E dimensional drawing
(Unit: mm)
| Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IDFB55E | 2 | 18.5 [470] | 33.7 [855] | 31.5 [800] | 5.0 [128] | 17.9 [455] | 34.2 [868] | 4.3 [110] | 9.8 [250] | 2 [50] | 0.5 [13] | 19.7 [500] | 3.0 [75] | 27.6 [700] | 20.7 [526] | 20.4 [519] | 1.4 [36] |
| IDFB75E | 2 | 35.4 [900] | 38.1 [968] |
*See the manufacturer's catalog for product information other than the above.
| Part Number |
|---|
| IDFB55E-46-R |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Air Inlet Flow (l/min) | Outlet Open Air Pressure Dew-point (℃) | Supply Side, Connection Type | Inlet Air Pressure (MPa) | Control Side, Connection Type | Standard size | Auto drain | Short-circuit Breaker | Operation, Terminal block for abnormal signal takeout |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 45,761.99 | 1 Piece(s) | 26 Day(s) or more | 6,400 / 7,300 / 8,400 | 2.8 ~ 10 | [Rc(R)] R | 0.7 | [Rc(R)] R | 55E | None | Yes | None |
Loading...
| Type | Dryer | Method | Refrigerating type (air-cooling specification) | Shape | Standard |
|---|---|---|---|---|---|
| Air Inlet Flow Rate [Distinction](l/min) | More than 5000 | Inlet Air Temperature(℃) | 37.8 | Supply Side, Plumbing Thread Nominal | 2 |
| Control Side, Plumbing Thread Nominal | 2 | Power Supply Voltage | Three-phase 460 V AC (60 Hz) | For medium pressure air | None |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy