Refrigerated air dryer with improved corrosion resistance due to the use of a stainless-steel heat exchanger.
[Features]
· Protects pneumatic equipment from moisture.
· Removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.
· Air flow capacity increased up to 40%.
· Power consumption reduced up to 40%.
· Energy-saving design.
· Exhaust heat reduced by 25%, controlling increases in ambient temperature (air-cooled specification) and reducing heat discharging water amount (water-cooled specification).
· Inlet air temperature: 35°C (22E, 37E) / 40°C (55E, 75E).
· Outlet air pressure dew point: 10°C.
Part Number
Configured Part Number is shown.
IDF22E-30-CL

IDF22E external appearance

IDF75E external appearance

IDF□E Series JIS symbol
| Specifications | Model | ||||||
|---|---|---|---|---|---|---|---|
| Standard-temperature air inlet | |||||||
| IDF22E | IDF37E | IDF55E | IDF75E | ||||
| Operating range*3 | Applicable fluid | Compressed Air | |||||
| Inlet air temperature (°C) | 5 to 50 | ||||||
| Inlet air pressure (MPa) | 0.15 to 1.0 | ||||||
| Ambient temperature (humidity) (°C) | 2 to 40 (Relative humidity of 85% or less) | ||||||
| *4 | Air flow capacity m3/min | Standard condition (ANR)*1 | 50 Hz | 3.9 | 5.7 | 8.4 | 11.0 |
| 60 Hz | 4.3 | 6.1 | 9.8 | 12.4 | |||
| Compressor intake condition*2 | 50 Hz | 4.1 | 6.1 | 8.9 | 11.7 | ||
| 60 Hz | 4.6 | 6.5 | 10.4 | 13.2 | |||
| Inlet air pressure (MPa) | 0.7 | ||||||
| Inlet air temperature (°C) | 35 | 40 | |||||
| Ambient temperature (°C) | 32 | ||||||
| Outlet air pressure dew point (°C) | 10 | ||||||
| Power supply voltage (frequency)*5 | Single-phase/Three-phase 200 V AC (50 Hz)*5 Single-phase/Three-phase 200/220 V AC (60 Hz) | Three-phase 200 V AC (50 Hz) Three-phase 200/220 V AC (60 Hz) | |||||
| Electric specifications | Power consumption*6 (W) 50/60 Hz | Single-phase 200 V | 810/940 | 810/940 | - | - | |
| Three-phase 200 V | 850/1,070 | 850/1,070 | 1,450/1,890 | 2,000/2,500 | |||
| Operating current*6 (A) 50/60 Hz | Single-phase 200 V | 4.3/4.7 | 4.3/4.7 | - | - | ||
| Three-phase 200 V | 3.3/3.5 | 3.3/3.5 | 6.0/6.6 | 7.2/8.0 | |||
| Applicable circuit breaker capacity*7 (A) (Sensitivity current of 30 mA) | 10 (200 V AC) | 15 (200 V AC) | |||||
| Condenser | Air-cooled | ||||||
| Refrigerant | R407C (HFC) | ||||||
| Refrigerant charge (kg) | Single-phase 200 V | 0.42 | 0.73 | - | - | ||
| Three-phase 200 V | 0.47 | 0.83 | 0.55 | 0.72 | |||
| Auto drain | Float type (normally open) | ||||||
| Port size | R1 | R1 1/2 | R2 | ||||
| Weight (kg) | 54 | 62 | 100 | 116 | |||
| Coating color | Body panel: urban white 1 Base: urban gray 2 | ||||||
| Applicable compressor output (Reference) (kW) For screw type | 22 | 37 | 55 | 75 | |||
*1: Indicates the air flow capacity under the standard condition (ANR) (atmospheric pressure 20°C, relative humidity 65%).
*2: Indicates the air flow capacity converted by the compressor intake condition (atmospheric pressure 32°C, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*5: Refer to "How to Order" in the manufacturer's catalog when selecting the power supply voltage.
*6: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*7: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
Humid, hot air coming into the air dryer is cooled down by a cooler re-heater (heat exchanger). Water condensed at this time is drained out automatically by the auto drain. Air separated from the water is heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side.

Structure principle diagram: IDF22E/IDF37E/IDF55E/IDF75E
(Unit: mm)

Dimensional drawing: IDF22E/IDF37E
(Unit: mm)

IDF55E/IDF75E dimensional drawing
(Unit: mm)
| Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IDF22E | R1 | 290 | 775 | 623 | 134 | 405 | 698 | 93 | 46 | 25 | 13 | 314 | 85 | 600 | 340 | - | - |
| IDF37E | R1 1/2 | 855 | 680 | ||||||||||||||
| IDF55E | R2 | 470 | 855 | 800 | 128 | 455 | 868 | 110 | 36 | 50 | 13 | 500 | 75 | 700 | 526 | 250 | 519 |
| IDF75E | 900 | 968 |
| Part Number |
|---|
| IDF22E-30-CL |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Air Inlet Flow (l/min) | Air Inlet Flow Rate [Distinction] (l/min) | Outlet Open Air Pressure Dew-point (℃) | Inlet Air Temperature (℃) | Inlet Air Pressure (MPa) | Supply Side, Plumbing Thread Nominal | Control Side, Plumbing Thread Nominal | Power Supply Voltage | Specifications | Air Compressor Size | Auto drain | For Compressed Air Cooling | Copper Tube Anti-rust Processing | Short-circuit Breaker | Operation, Terminal block for abnormal signal takeout | Chinese nameplate, Chinese operation manual |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz) | None | 22 kW | With heavy-duty auto drain | None | Yes | None | None | None |
Loading...
| Type | Dryer | Method | Refrigerating type (air-cooling specification) | Shape | Standard |
|---|---|---|---|---|---|
| Supply Side, Connection Type | R | Control Side, Connection Type | R |
Please check the type/dimensions/specifications of the part IDF22E-30-CL in the Refrigerated Air Dryer Standard Temperature Air Inlet, IDF□E Series series.
| Part Number |
|---|
| IDF22E-20-ACGR |
| IDF22E-20-ACKRT |
| IDF22E-20-ACLR |
| IDF22E-30-CLR |
| IDF22E-30-CLRT |
| IDF22E-30-CLT |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Air Inlet Flow (l/min) | Air Inlet Flow Rate [Distinction] (l/min) | Outlet Open Air Pressure Dew-point (℃) | Inlet Air Temperature (℃) | Inlet Air Pressure (MPa) | Supply Side, Plumbing Thread Nominal | Control Side, Plumbing Thread Nominal | Power Supply Voltage | Specifications | Air Compressor Size | Auto drain | For Compressed Air Cooling | Copper Tube Anti-rust Processing | Short-circuit Breaker | Operation, Terminal block for abnormal signal takeout | Chinese nameplate, Chinese operation manual |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | - | 35 | - | 1 | 1 | - | None | 22 kW | None | Yes | Yes | Yes | None | Yes | ||
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz) | Medium air pressure specification (Case for auto drain: metal case with level gauge) | 22 kW | None | Yes | Yes | Yes | Yes | None | ||
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz) | None | 22 kW | With heavy-duty auto drain | Yes | Yes | Yes | None | None | ||
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz) | None | 22 kW | With heavy-duty auto drain | None | Yes | Yes | None | None | ||
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz) | None | 22 kW | With heavy-duty auto drain | None | Yes | Yes | Yes | None | ||
- | 1 Piece(s) | Quote | 3,900 / 4,300 | ~5000 | 10 | 35 | 0.7 | 1 | 1 | Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz) | None | 22 kW | With heavy-duty auto drain | None | Yes | None | Yes | None |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy