Electrostatic sensor that detects the electrostatic potential of a workpiece and outputs in analog voltage.
[Features]
·It is important to check the "actual condition" for static electricity management
·A wide range of charge potential measurements is possible
·Compact size and easy shape to install
·Installation range (IZD10-110): 10 to 50 mm (±0.4 kV when the installation distance is 25 mm)
·Installation range (IZD10-510): 25 to 75 mm (±20 kV when the installation distance is 50 mm)
Part Number
Configured Part Number is shown.
| Electrostatic Sensor Type | IZD10-110 | IZD10-510 |
|---|---|---|
| Potential Measurement | ±0.4 kV (detection range at 25 mm)* | ±20 kV (detection range at 50 mm)* |
| Output Voltage | 1 to 5 V (Output impedance: Approx. 100Ω) | |
| Effective Detection Distance | 10 to 50 mm | 25 to 75 mm |
| Linearity | ±5% F.S. (0 to 50°C, at detection distance of 25 mm) | ±5%F.S. (0 to 50°C, at detection distance of 50 mm) |
| Output Delay Time | 100 ms or less | |
| Power Supply Voltage | 21.6 to 26.4 V DC (Within 24 V DC ±10%) | |
| Current Consumption | 40 mA or less | |
| Ambient Operating Temperature | 0 to 50°C | |
| Ambient Humidity | 35 to 85% Rh (with no condensation) | |
| Material | Head case: ABS, Amplifier case: ABS | |
| Vibration Resistance | Durability 50 Hz, Amplitude 1 mm, X, Y, Z: 2 hours each | |
| Impact Resistance | 100 m/s2 | |
| Weight | 185 g (including cable weight) | |
| Compliance with EN Standards | Protective Class: Class III (EN60950-1) Pollution Degree 3 CE Marking: Low voltage directive: 2006/95/EC Only when connected to a SELV-type external circuit | |
| EMC Directive | 2004/108/EC | |
| UL Standard | UL508 | |
*The measured potential and output voltage varies depending on the detection distance. For details of the relationship between measured potentials and output voltages according to detection distance, refer to the "Output Signal" graphs in the Technical Data section of the catalog.
Connect the lead wires according to the connection circuit and wiring table.

IZD10 Series connection circuit
| Lead Wire Coating Color | Description | Function |
|---|---|---|
| Brown | DC (+) | Power supply 24 V DC |
| Blue | DC (-) | Power Supply 0 V |
| White | Sensor output | Analog output for 1 to 5 V |
(Unit: mm)

IZD10-110/IZD10-510 dimensional drawing 1
(Unit: mm)

IZD10-110/IZD10-510 dimensional drawing 2
(Unit: mm)

IZD10-110/IZD10-510 dimensional drawing 3
When measuring the potential of a charged object with an electrostatic sensor, the relationship between the electrostatic potential being measured and the output voltage varies depending on the sensor's installation distance. The relationship between the electrostatic sensor's output voltage and the detected electrostatic potential depending on the installation distance is as shown in the figure below. (The installation distance in the figure refers to the distance between the object being measured and the electrostatic sensor.)

IZD10-110 electrostatic potential graph

IZD10-510 electrostatic potential graph

IZD10 Series detection range

IZD10 Series part names
| Installation Range (mm) | Detection Range (mm) |
|---|---|
| 10 | 45 |
| 20 | 85 |
| 25 | 100 |
| 30 | 120 |
| 40 | 150 |
| 50 | 180 |
| Installation Range (mm) | Detection Range (mm) |
|---|---|
| 25 | 100 |
| 30 | 120 |
| 40 | 150 |
| 50 | 180 |
| 60 | 205 |
| 70 | 225 |
| 75 | 235 |
Loading...
| Type | Antistatic Measurement Devices | Indicators | Not Provided | Additional Function | Not Provided |
|---|---|---|---|---|---|
| Ion Balance Adjusting Function | Not Provided | Power Supply | DC24V |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy