SMC Solenoid Valve.
[Features]
· A direct operated poppet type 3-port solenoid valve
· Supports various valve functions in 1 valve
· Low-concentration ozone-measure product
· Interchangeable

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Part Number

Configured Part Number is shown.

Part Number
VT307-1D1-01T
VT307-1DZ1-01T
VT307-1DZ1-02T
VT307-1G1-02T-F
VT307-1GS1-02T-F
VT307-2D1-01T
VT307-2G1-02T
VT307-3D1-01T
VT307-3DZ1-01T
VT307-3DZ1-02T
VT307-3DZ1-02T-F
VT307-3G1-01T
VT307-3G1-02T
VT307-3H1-02T
VT307-4D1-02T-Q
VT307-4DZ1-01T
VT307-4DZ1-02T
VT307-5D1-01T
VT307-5D1-01T-F-Q
VT307-5D1-02T-F-Q
VT307-5DZ1-01T
VT307-5DZ1-01T-F
VT307-5DZ1-02T
VT307-5DZ1-02T-F
VT307-5G1-01T-F
VT307-5G1-02T
VT307-5G1-02T-F
VT307-5GS1-01T
VT307-5GS1-02T
VT307-6DZ1-01T
VT307-6DZ1-02T
VT307-6G1-01T
VT307-6GS1-01T
VT307-6GS1-01T-F
VT307E-3DZ1-01T
VT307E-3DZ1-02T-F
VT307E-5D1-01T
VT307E-5DZ1-01T-F
VT307E-5DZ1-02T-F
VT307E-5G1-02T
VT307K-1H1-01T
VT307K-3D1-01T-Q
VT307K-3DZ1-02T
VT307K-3H1-01T
VT307K-3H1-02T
VT307K-3HS1-01T
VT307K-5DZ1-01T
VT307K-5H1-01T
VT307K-5HS1-01T
VT307K-6DZ1-01T
VT307K-7G1-02T
VT307V-5D1-02T
VT307V-5D1-02T-F
VT307V-5DZ1-01T
VT307W-5D1-01T-F-Q
VT307W-5DZ1-02T-F
VT307W-5G1-01T-F
VT307Y-5D1-02T-F
VT307Y-5DZ1-02T-F
VT307Y-5G1-01T-F
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplication Mounting Orientation Specifications Switching Type Voltage Pipe Port Type Plumbing Thread Nominal Plumbing CV Value Pressure Rating
(MPa)
Pilot Air Supply Lead wire electrical entry Indicator light / Surge voltage suppressor Bracket CE compliant Body options

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC100VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC100VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC100VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

MYR 294.59

1 Piece(s) 13 Day(s) or more Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC100VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)NoneWith BracketNoneStandard type

MYR 318.27

1 Piece(s) 13 Day(s) or more Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC100VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)With surge voltage suppressorWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC200VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC200VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC110VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet / Lead wire length: 600 mmNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC220VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorNoneNoneCE compliant productStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC220VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC220VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorNoneWith BracketCE compliant productStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorNoneWith BracketYesStandard type

MYR 431.73

1 Piece(s) 21 Day(s) Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)NoneWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)NoneWith BracketNoneStandard type

MYR 381.40

1 Piece(s) 21 Day(s) Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)With surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalGrommet (lead wire length: 300 mm)With surge voltage suppressorNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC12VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC12VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

MYR 351.37

1 Piece(s) 21 Day(s) Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC12VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC12VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)With surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC12VNPTF1/8Direct Plumbing0.180 to 0.7InternalGrommet (lead wire length: 300 mm)With surge voltage suppressorWith BracketNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/8Direct Plumbing0.10 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.120 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.10 to 0.7InternalDIN terminal with connectorNoneNoneNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.10 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.120 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.120 to 0.7InternalGrommet (lead wire length: 300 mm)NoneNoneNoneLong-loading-time type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC100VNPTF1/8Direct Plumbing0.180 to 1.0InternalGrommet / Lead wire length: 600 mmNoneNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC110VNPTF1/8Direct Plumbing0.180 to 1.0InternalDIN terminal with connectorNoneNoneCE compliant productStandard type

MYR 360.98

1 Piece(s) 13 Day(s) or more Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/4Direct Plumbing0.190 to 1.0InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

MYR 307.48

1 Piece(s) 13 Day(s) or more Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/8Direct Plumbing0.180 to 1.0InternalGrommet / Lead wire length: 600 mmNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC110VNPTF1/4Direct Plumbing0.190 to 1.0InternalGrommet / Lead wire length: 600 mmNoneNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedAC110VNPTF1/8Direct Plumbing0.180 to 1.0InternalGrommet / Lead wire length: 600 mmWith surge voltage suppressorNoneNoneStandard type

MYR 452.03

1 Piece(s) 21 Day(s) Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 1.0InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 1.0InternalGrommet / Lead wire length: 600 mmNoneNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 1.0InternalGrommet / Lead wire length: 600 mmWith surge voltage suppressorNoneNoneStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalDC12VNPTF1/8Direct Plumbing0.180 to 1.0InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalAC240VNPTF1/4Direct Plumbing0.190 to 1.0InternalGrommet (lead wire length: 300 mm)NoneNoneNon-compliantStandard type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorNoneNoneNoneVacuum specification

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.190 to 0.7InternalDIN terminal with connectorNoneWith BracketNoneVacuum specification

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.180 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorNoneNoneVacuum specification

-

1 Piece(s) Quote Single UseDirectOzone Compatible / Lubrication Free / Low Current[Others] 2 positions universalDC24VNPTF1/8Direct Plumbing0.10 to 0.7InternalDIN terminal with connectorNoneWith BracketCE compliant productLow power consumption type / Vacuum specification type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.120 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneLow power consumption type / Vacuum specification type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.10 to 0.7InternalGrommet (lead wire length: 300 mm)NoneWith BracketNoneLow power consumption type / Vacuum specification type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.120 to 0.7InternalDIN terminal with connectorNoneWith BracketNoneLow power consumption type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/4Direct Plumbing0.120 to 0.7InternalDIN terminal with connectorWith indicator light and surge voltage suppressorWith BracketNoneLow power consumption type

-

1 Piece(s) Quote Single UseDirectStandard / Ozone Compatible / Lubrication Free / Low Current2-Position Normally ClosedDC24VNPTF1/8Direct Plumbing0.10 to 0.7InternalGrommet (lead wire length: 300 mm)NoneWith BracketNoneLow power consumption type

Loading...

Basic Information

Type Solenoid Valves Number of Ports 3-Port Valve Number of Solenoids Single
Status at Power Off Self-Recovery (Spring Return) Driving Type Linear Motion Poppet Seal Type Soft Seal
Manual Switch Non-Locking

Additional Products in this Category