(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Power-saving, long-lifespan solenoid valve.
[Features]
· Cylinder actuation up to ø160 (160 mm diameter) is possible.
· Connector: Manifold.
· IP67-compliant protective structure.
· Compatible with numerous protocols.
· Thread type: Rc, G, NPT, NPTF.
· Piping specifications: Side ported / Bottom ported.
Part Number
Configured Part Number is shown.

Plug-In VQ4000 Series external appearance

Plug-In VQ4000 Series structure drawing
| Valve Specifications | Valve Construction | Metal Seal | Rubber Seal | ||
|---|---|---|---|---|---|
| Usable Fluids | Air, inert gases | ||||
| Maximum Operating Pressure | Standard (DC and AC) | 1.0 MPa | |||
| Low-watt type (DC) | |||||
| Minimum Operating Pressure | Single | 0.15 MPa | 0.20 MPa | ||
| Double | 0.15 MPa | 0.15 MPa | |||
| 3 position | 0.15 MPa | 0.20 MPa | |||
| Guaranteed Proof Pressure | 1.5 MPa | ||||
| Ambient Temperature and Operating Fluid Temperature | -10 to 50°C *1 | ||||
| Lubrication | Not required | ||||
| Manual Operation | Push type / locking type (tool required) | ||||
| Impact Resistance / Vibration Resistance | 150 / 30 m/s2 *2 | ||||
| Electrical Specifications | Enclosure | Dust-proof (can be IP65-compliant)*3 | |||
| Coil Rated Voltage | 12 V DC, 24 V, 100 V AC, 110 V, 200 V, 220 V (50/60 Hz) | ||||
| Allowable Voltage Fluctuation | ±10% of rated voltage | ||||
| Coil Insulation Type | Class B or equivalent | ||||
| Power Consumption W | DC | Standard | 0.95 | ||
| Low-watt type | 0.4 | ||||
| Apparent Power VA | AC | 100 V | 1.19 | ||
| 110 V | 1.32 | ||||
| 200 V | 1.90 | ||||
| 220 V | 2.08 | ||||
*1: Use dry air when operating at low temperatures. No condensation.
*2: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)
*3: T, L, S, C only.
| Series | Configuration | Model | Piping connection port diameter | Flow Rate Characteristics | Response time (ms) | Weight kg | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 → 4/2 (P → A/B) | 4/2 → 5/3 (A/B → EA/EB) | Standard: 0.95 W | Low-watt type: 0.4 W | AC | |||||||||||
| C (dm3 / [s·bar]) | b | Cv | C (dm3 / [s·bar]) | b | Cv | ||||||||||
| VQ4000 | 2 Position | Single | Metal Seal | VQ4100 | 3/8 | 6.2 | 0.19 | 1.5 | 6.9 | 0.17 | 1.7 | 20 | 22 | 22 | 0.23 |
| Rubber Seal | VQ4101 | 7.2 | 0.43 | 2.1 | 7.3 | 0.38 | 2.0 | 25 | 27 | 27 | |||||
| Double | Metal Seal | VQ4200 | 6.2 | 0.19 | 1.5 | 6.9 | 0.17 | 1.7 | 12 | 16 | 14 | 0.26 | |||
| Rubber Seal | VQ4201 | 7.2 | 0.43 | 2.1 | 7.3 | 0.38 | 2.0 | 15 | 17 | 17 | |||||
| 3 Position | Closed Center | Metal Seal | VQ4300 | 5.9 | 0.23 | 1.5 | 6.3 | 0.18 | 1.6 | 45 | 47 | 47 | 0.28 | ||
| Rubber Seal | VQ4301 | 7.0 | 0.34 | 1.9 | 6.4 | 0.42 | 1.9 | 50 | 52 | 52 | |||||
| Exhaust Center | Metal Seal | VQ4400 | 6.2 | 0.18 | 1.5 | 6.9 | 0.17 | 1.7 | 45 | 47 | 47 | 0.28 | |||
| Rubber Seal | VQ4401 | 7.0 | 0.38 | 1.9 | 7.3 | 0.38 | 2.0 | 50 | 52 | 52 | |||||
| Pressure Center | Metal Seal | VQ4500 | 6.2 | 0.18 | 1.6 | 6.4 | 0.18 | 1.6 | 45 | 47 | 47 | 0.28 | |||
| Rubber Seal | VQ4501 | 7.0 | 0.38 | 1.9 | 7.1 | 0.38 | 2.0 | 50 | 52 | 52 | |||||
| Perfect | Metal Seal | VQ4600 | 2.7 | - | - | 3.7 | - | - | 55 | 57 | 57 | 0.50 | |||
| Rubber Seal | VQ4601 | 2.8 | - | - | 3.9 | - | - | 62 | 64 | 64 | |||||
*1: The cylinder port size of 3/8 is the value for when equipped with a sub-plate.
*2: Based on JIS B 8419:2010 (The value shown is when supply pressure is 0.5 MPa when equipped with an indicator light / surge voltage suppressor, and when using clean air. The values may change depending on the pressure and air. ) Double type value when ON.
*3: The table shows models without a sub-plate. When equipped with a sub-plate, add 0.41 kg for the plug-in type.
(Unit: mm)

2-position single: VQ4100/1-□ dimensional drawing
(Unit: mm)

2-position single: VQ4100/1-□ bottom ported dimensional drawing
*Values inside parentheses are for 3/8"
(Unit: mm)

2-position double: VQ4200/1-□, 3-position closed center: VQ4300/1-□, 3-position exhaust center: VQ4400/1-□, 3-position pressure center: VQ4500/1-□ dimensional drawings
(Unit: mm)

3-position perfect: VQ4600/1-□ dimensional drawing

2-position single indicator symbol

Symbols for 3-position closed center

Symbols for 3-position exhaust center

Single-action fitting replacement method
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Application | Mounting Orientation | Specifications | Number of Solenoids | Switching Type | Status at Power Off | Voltage | Pipe Port Type | Plumbing Thread Nominal | CV Value | Seal Type | Pressure Rating (MPa) | Pilot Air Supply | Manual Switch | Manual | Indicator light / Surge voltage suppressor | Piping specifications | Functions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 701.13 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 690.99 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC24V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 785.57 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC12V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Lock | - | Yes | Bottom ported | Low-watt type (0.4 W) | ||
MYR 690.64 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 695.30 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC24V | NPTF | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 667.31 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Lock | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 662.24 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Lock | Locking type (hand-operated) | Yes | Side ported | Standard (0.95 W) | ||
MYR 639.01 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 639.01 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | NPT | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 643.67 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC24V | NPTF | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 651.55 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | [Single] Single | 2-Position Exhaust | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | External | Non-Locking | - | Without indicator light / With surge voltage suppressor | Side ported | External pilot | ||
MYR 638.60 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | [Single] Single | 2-Position Normally Open | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 836.21 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | Double | 2-Position Normally Open | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 824.96 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 2-Position Exhaust | Self-Retaining | DC24V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 888.04 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 2-Position Exhaust | Self-Retaining | DC24V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Bottom ported | Standard (0.95 W) | ||
MYR 829.29 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | Double | 2-Position Normally Open | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 832.89 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 2-Position Exhaust | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.15 to 1 | Internal | Lock | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 774.10 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | Double | 2-Position Normally Open | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 777.65 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 2-Position Exhaust | Self-Retaining | DC24V | G | 1/4 | - | Soft Seal | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 793.45 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 2-Position Exhaust | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.15 to 1 | External | Non-Locking | - | Without indicator light / With surge voltage suppressor | Side ported | External pilot | ||
MYR 796.77 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | Double | 2-Position Normally Open | Self-Retaining | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 1,014.18 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Lock | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 990.60 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Lock | - | Without indicator light / With surge voltage suppressor | Side ported | Standard (0.95 W) | ||
MYR 998.43 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Lock | - | Without indicator light / With surge voltage suppressor | Side ported | Standard (0.95 W) | ||
MYR 970.98 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 959.04 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | NPT | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 959.04 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | NPTF | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 941.78 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Without indicator light / With surge voltage suppressor | Side ported | Low-watt type (0.4 W) | ||
MYR 964.01 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 902.39 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 965.41 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Bottom ported | Standard (0.95 W) | ||
MYR 916.79 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Closed Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 956.18 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 949.71 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | NPTF | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 957.54 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 908.86 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 911.72 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | NPT | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | - | Yes | Side ported | Standard (0.95 W) | ||
MYR 910.45 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Exhaust Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 956.18 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Pressure Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 964.01 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Pressure Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 908.86 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | 3-Position Pressure Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 927.48 | 1 Piece(s) | 27 Day(s) or more | Single Use | Direct | Drip-Proof / Lubrication Free | Double | 3-Position Pressure Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | External | Non-Locking | - | Without indicator light / With surge voltage suppressor | Side ported | External pilot | ||
MYR 916.79 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | 3-Position Pressure Center | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 1,391.17 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Without indicator light / With surge voltage suppressor | Side ported | Standard (0.95 W) | ||
MYR 1,436.15 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 1,429.28 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Standard | 0.15 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) | ||
MYR 1,358.33 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Without indicator light / With surge voltage suppressor | Side ported | Standard (0.95 W) | ||
MYR 1,374.04 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | Standard | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Standard (0.95 W) | ||
MYR 1,367.49 | 1 Piece(s) | 23 Day(s) or more | Single Use | Direct | - | - | [Others] 3 positions perfect | Self-Recovery (Spring Return) | DC24V | [Rc (R)] Rc | 1/4 | - | Soft Seal | 0.2 to 1 | Internal | Non-Locking | Non-locking push type (tool required) | Yes | Side ported | Low-watt type (0.4 W) |
Loading...
| Type | Solenoid Valves | Number of Ports | 5-Port Valve | Applicable Cylinder Dia.(Ø) | 200 or less |
|---|---|---|---|---|---|
| Plumbing | Sub-Base Plumbing | Driving Type | Pilot Type Spool |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy