· Prevents vibrations to the shaft sliding part, increasing the lifespan of rubber parts. It also helps improve the valve sealing performance.
· Completely stops the leakage of coolant fluid. The scraper effect provides double the safety performance.
· The sealing material can also be selected (NBR, FKM).
· Includes a function for checking whether the valve is open or closed. Mountable on either side (SGC2/3/4 only).
· Prevents the loss of grease, increasing its service life.
· External pilot solenoid type and air operated type.
· Series: SGC200/SGC300SGC400.
· Valve type: N.C./N.O.
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Plumbing Thread Nominal | Switching Type | Driving Type | Connection Type | Orifice Dia. (Ø) | Voltage | Sealing materials | Option | Bracket | Lead wire length (mm) | Lead wire electrical entry | Integrated pilot valve | Applicable switch | Number of switches | Manual operation type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,525.20 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,596.44 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,591.93 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,659.47 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9NA | 2 pcs. | Non-locking, push type | ||
MYR 1,722.54 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 5,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9BA | 2 pcs. | Non-locking, push type | ||
MYR 1,296.83 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,541.00 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,591.93 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on right side | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,549.13 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,462.37 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 5,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9BA | 1 pc. | Non-locking, push type | ||
MYR 1,249.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,201.95 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Push-turn locking lever type | ||
MYR 1,158.94 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,230.19 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,478.17 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,241.59 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Push-turn locking lever type | ||
MYR 1,501.76 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,245.90 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,218.00 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,521.87 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,553.39 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 3,000 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,521.87 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,569.19 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,545.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 3,000 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,229.90 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,277.46 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Push-turn locking lever type | ||
MYR 1,312.54 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | M12 connector (4 pin specification) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,360.53 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | M12 connector (4 pin specification) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,349.04 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | M12 connector (4 pin specification) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,324.78 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 3/8 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | M12 connector (4 pin specification) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Push-turn locking lever type | ||
MYR 1,186.44 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | None | No bracket | 500 | DIN terminal without connector | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,501.76 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | None | No bracket | 500 | DIN terminal without connector | 0.35‑W type (V116) | D-M9P | 2 pcs. | Push-turn locking lever type | ||
MYR 1,214.39 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,493.68 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,591.93 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,722.54 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 5,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9NA | 2 pcs. | Non-locking, push type | ||
MYR 1,485.76 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,517.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,395.92 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 1 pc. | Non-locking, push type | ||
MYR 1,525.49 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 1,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,198.63 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,218.00 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,301.14 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,647.97 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 3,000 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9BA | 2 pcs. | Non-locking, push type | ||
MYR 1,253.83 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 100 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,206.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,214.39 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,549.13 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,249.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,578.26 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Push-turn locking lever type | ||
MYR 1,218.00 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,521.87 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,265.32 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,229.90 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 200 V AC 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,214.39 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 110 V AC (115 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,262.33 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 110 V AC (115 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,383.29 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 110 V AC (115 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 1 pc. | Push-turn locking lever type | ||
MYR 1,218.00 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 110 V AC (115 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,214.39 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,261.70 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on right side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,216.83 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,299.97 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,252.65 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 220 V AC (230 V AC) 50/60 Hz | NBR | With light and surge voltage suppressor | No bracket | 500 | Conduit terminal (pilot valve V116 only) | 0.35‑W type (V116) | Without auto switch (built-in magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,190.75 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,486.05 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9B | 2 pcs. | Non-locking, push type | ||
MYR 1,186.44 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | DIN terminal without connector | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,233.71 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | Bracket on left side | 500 | DIN terminal without connector | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,206.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,254.45 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,253.83 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With surge voltage suppressor | Bracket on right side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,218.63 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | None | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Push-turn locking lever type | ||
MYR 1,214.44 | 1 Piece(s) | 10 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type | ||
MYR 1,517.56 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | No bracket | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9P | 2 pcs. | Non-locking, push type | ||
MYR 1,261.76 | 1 Piece(s) | 10 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 500 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | Without auto switch (without magnet) | 2 pcs. | Non-locking, push type | ||
MYR 1,572.51 | 1 Piece(s) | 23 Day(s) or more | Electromagnetic Type | 1/2 | Normally Closed | Pilot Type | [Rc (R)] Rc | 12 | 24 V DC | NBR | With light and surge voltage suppressor | Bracket on left side | 3,000 | DIN terminal (terminal pitch: 11 mm) | 0.35‑W type (V116) | D-M9N | 2 pcs. | Non-locking, push type |
Loading...
| Applicable Fluid | Coolant | Operating Environment | Standard | Operating Temperature Range(°C) | -5::50 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy