(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
SMC Solenoid Valve.
[Features]
· Solenoid valves that can be used with various fluids in a wide variety of applications
· Improved corrosion resistance
· Enclosure: Equivalent to IP65
· Low noise construction
· Reduced power consumption
· UL94V-0 conforming flame resistance
· Improved maintenance performance
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Orifice Dia. (Ø) | Operating Temperature Range (°C) | Operating Pressure Differential Range (MPa) | Application | Insulation Class | Voltage | Sealing materials | Option | Body material | Bracket | Detailed type | Power consumption (W) | Functions | Lead wire electrical entry | Apparent power (VA) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | 1/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | G | 1.5 | -20~40 | ~1 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | NPT | 1.5 | -20~40 | ~1 | Single Item | B | 12 V DC | EPDM | - | SUS | None | - | 4.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | NPT | 1.5 | -20~40 | ~1 | Single Item | B | 12 V DC | EPDM | - | SUS | Included | - | 4.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 1.5 | -20~60 | ~1 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 1.5 | -20~60 | ~1 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Open | NPT | 1.5 | -20~40 | ~1 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Open | NPT | 1.5 | -20~40 | ~1 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | NPTF | 1.5 | -20~40 | ~0.7 | Single Item | B | 12 V DC | EPDM | - | SUS | Included | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | Water | 1/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 1.5 | -20~60 | ~0.7 | Single Item | H | 220 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | G | 2.2 | -20~40 | ~0.7 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | NPT | 2.2 | -20~40 | ~0.7 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~40 | ~0.4 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~60 | ~0.4 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~60 | ~0.4 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | With conduit terminal | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~60 | ~0.4 | Single Item | H | 200 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | NPT | 3 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 3 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 1/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 220 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 3 | -20~40 | ~0.2 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 4.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 3 | -20~40 | ~0.2 | Single Item | B | 12 V DC | EPDM | - | SUS | None | - | 4.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~40 | ~0.2 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 4.5 | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.2 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~60 | ~0.7 | Single Item | H | 110 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 2.2 | -20~60 | ~0.7 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | G | 3 | -20~40 | ~0.6 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 7 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 3 | -20~40 | ~0.6 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 7 | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Open | [Rc (R)] Rc | 3 | -20~60 | ~0.5 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | NPTF | 3 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 7 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | With conduit terminal | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit terminal / With light | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit terminal with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Conduit terminal with surge voltage suppressor and light | - | ||
MYR 859.03 | 1 Piece(s) | 21 Day(s) | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 4 | -20~40 | ~0.2 | Single Item | B | 24 V DC | EPKM | None | SUS | Included | None | 7 | None | For DIN terminal (without connector, gasket included) | - | ||
- | 1 Piece(s) | Quote | - | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 4 | -20~60 | ~0.2 | Single Item | B | 230 V AC 50/60 Hz | EPDM | - | SUS | None | - | - | Built-in full wave rectifier type | DIN terminal | 9.5 | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~60 | ~0.2 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~60 | ~0.2 | Single Item | H | 200 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Conduit terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | NPT | 4 | -20~60 | ~0.2 | Single Item | H | 110 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | With conduit terminal | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | G | 2.2 | -20~40 | ~1.6 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 10.5 | None | DIN terminal | - | ||
- | 1 Piece(s) | Quote | - | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 3 | -20~40 | ~1 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 10.5 | None | Grommet with surge voltage suppressor | - | ||
MYR 984.40 | 1 Piece(s) | 21 Day(s) | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 3 | -20~40 | ~0.6 | Single Item | B | 24 V DC | EPKM | None | SUS | Included | None | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | NPTF | 3 | -20~60 | ~0.6 | Single Item | H | 240 V AC 50/60Hz | EPDM | - | SUS/Ag | Included | - | - | None | Conduit terminal with surge voltage suppressor | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 4 | -20~40 | ~0.5 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 10.5 | None | Grommet | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 4 | -20~40 | ~0.5 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 10.5 | None | Grommet | - | ||
MYR 974.25 | 1 Piece(s) | 21 Day(s) | - | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 4 | -20~40 | ~0.5 | Single Item | B | 24 V DC | EPKM | None | SUS | None | None | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
MYR 984.40 | 1 Piece(s) | 21 Day(s) | - | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Closed | [Rc (R)] Rc | 4 | -20~40 | ~0.5 | Single Item | B | 24 V DC | EPKM | None | SUS | Included | None | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | Normally Open | [Rc (R)] Rc | 4 | -20~60 | ~0.4 | Single Item | H | 100 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Conduit terminal with surge voltage suppressor and light | - | ||
MYR 984.40 | 1 Piece(s) | 21 Day(s) | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPKM | None | SUS | Included | None | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | NPT | 4 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | - | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 4 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | None | - | 10.5 | None | DIN terminal with surge voltage suppressor and light | - | ||
- | 1 Piece(s) | Quote | - | 1/4 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 4 | -20~40 | ~0.3 | Single Item | B | 24 V DC | EPDM | - | SUS | Included | - | 10.5 | None | Grommet | - | ||
MYR 959.25 | 1 Piece(s) | 21 Day(s) | Water | 1/4 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~60 | ~0.3 | Single Item | H | 100 V AC 50/60 Hz | EPDM | None | SUS/Ag | Included | None | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | G | 4 | -20~60 | ~0.3 | Single Item | H | 230 V AC 50/60 Hz | EPDM | - | SUS/Ag | None | - | - | None | Grommet | - | ||
- | 1 Piece(s) | Quote | Water | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~60 | ~0.3 | Single Item | H | 200 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet | - | ||
MYR 839.88 | 1 Piece(s) | 13 Day(s) or more | Water | 3/8 | No oil / Dust Resistant / Jet Proof Type / No Copper, Fluoro Material | 3-Port Universal | [Rc (R)] Rc | 4 | -20~60 | ~0.3 | Single Item | H | 200 V AC 50/60 Hz | EPDM | - | SUS/Ag | Included | - | - | None | Grommet with surge voltage suppressor | - |
Loading...
| Type | Electromagnetic Type | Driving Type | Linear Motion Type | IP | IP65 |
|---|---|---|---|---|---|
| Acquired Standards | CE |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy