SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 618.53 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 568.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 626.41 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 561.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | EPDM | IN side (standard) | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 584.62 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 90° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 555.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 90° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 270° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 581.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 575.34 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 637.93 | 1 Piece(s) | 3 Day(s) | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | 90° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 539.71 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 10 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 568.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 641.98 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 655.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 561.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 90° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 555.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 270° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 573.17 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 90° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 180° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 270° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 581.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 10 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 555.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | EPDM | IN side (standard) | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 581.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 569.14 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 581.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 90° | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 551.84 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 547.58 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 10 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 638.60 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 638.60 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 663.45 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 675.63 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 578.21 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 270° | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 550.96 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 568.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 551.84 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 644.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 569.14 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 90° | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 581.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 90° | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | 270° | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 550.96 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 564.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 576.69 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 527.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 595.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 533.18 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | EPDM | IN side (standard) | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 545.18 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 552.77 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 557.37 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 533.73 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 595.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 515.06 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy