SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 618.57 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | C37 | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 618.57 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~1 | H | None | 220 V AC | EPDM | Standard | None | C37 | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 617.25 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | SUS | None | High temperature water | None | Grommet | ||
MYR 738.71 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 771.18 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | 270° | None | SUS | Included | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 789.59 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | Included | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | 90° | None | SUS | Included | High temperature water | None | Grommet | ||
MYR 701.67 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 750.20 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | 180° | None | SUS | Included | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 742.28 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | 90° | None | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 734.65 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | EPDM | 90° | Oil-free | SUS | Included | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 773.84 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | SUS | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 110 V AC | FKM | Standard | None | C37 | None | High temperature oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 523.95 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 110 V AC | FKM | Standard | None | C37 | None | High temperature oil | None | Conduit (With surge voltage suppressor) | ||
MYR 736.80 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | FKM | Standard | None | SUS | None | High temperature oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 683.56 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | H | None | 24 V DC | FKM | Standard | None | SUS | None | High temperature oil | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 486.35 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Grommet | ||
MYR 499.49 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Grommet | ||
MYR 496.70 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | None | C37 | None | Air | None | Grommet | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet | ||
MYR 581.99 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | Grommet | ||
MYR 593.65 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 486.35 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 499.49 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 496.70 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | 180° | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 506.89 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 486.35 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 530.58 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 555.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 561.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 90° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 584.62 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 636.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 655.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 638.60 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 548.75 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 568.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 641.98 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 655.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 200 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 551.84 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 492.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Faston | ||
MYR 513.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 486.35 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet | ||
MYR 520.89 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | None | C37 | Included | Air | Special voltage | Grommet | ||
MYR 538.34 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | Oil-free | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 535.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 539.71 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 484.51 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 574.29 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 587.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 587.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 581.99 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 683.22 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 669.99 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 707.20 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 574.29 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 574.29 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 587.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 600.17 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | 90° | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 587.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | 270° | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 574.29 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 587.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | 270° | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 576.95 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 600.37 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 608.25 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 516.02 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 1,203.90 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | SUS | None | Air | None | Grommet | ||
MYR 1,195.19 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | Air | None | Grommet | ||
MYR 1,195.19 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | None | SUS | None | Air | None | Grommet | ||
MYR 1,218.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,270.50 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,182.56 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | None | SUS | None | Air | None | Grommet (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy