SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 798.58 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 699.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 657.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 705.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 801.73 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 657.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 799.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 680.41 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 662.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 687.08 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 688.11 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 691.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 685.73 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | 90° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 675.42 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 692.53 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 682.48 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 622.80 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 622.80 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 634.29 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 610.66 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | Faston | ||
MYR 605.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 729.78 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 618.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | Included | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 649.66 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 12 V DC | NBR | 180° | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | Included | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 650.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 657.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 605.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 13 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 838.17 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 719.20 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 90° | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 719.20 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 719.20 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 270° | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 714.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 709.55 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 90° | Oil-free | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 712.98 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 730.78 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 689.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 689.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 230 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 706.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 240 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 695.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 726.52 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 695.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | None | C37 | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 718.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 718.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy