SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 455.27 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 270° | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 484.33 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 442.64 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 484.51 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | EPDM | 180° | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 450.40 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 481.83 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | 90° | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 463.14 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | 270° | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 470.61 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.34 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 488.90 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 10 | 0~1 | B | None | 200 V AC | NBR | 90° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 441.50 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 450.40 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 463.14 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | 270° | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 455.27 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | 90° | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 455.27 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | 270° | Oil-free | Aluminum | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 450.40 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 10 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 471.40 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 432.05 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 453.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 445.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 180° | Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 445.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 270° | Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 453.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 432.05 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 453.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | 90° | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 466.35 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 453.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | 270° | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 240 V AC | NBR | Standard | Oil-free | Aluminum | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 408.72 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | Aluminum | Included | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 434.79 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | 180° | Oil-free | Aluminum | Included | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 377.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 407.59 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | EPDM | Standard | Oil-free | Resin | None | Air | None | Grommet | ||
MYR 377.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 389.25 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | EPDM | IN side (standard) | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~1 | B | With one-touch fitting | 200 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 421.97 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 396.09 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 440.03 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 270° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 409.94 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 90° | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 409.94 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 180° | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 409.94 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 270° | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 408.72 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 399.66 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 421.97 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 12 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 465.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.34 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | EPDM | Standard | Oil-free | Resin | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 449.38 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 270° | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 436.94 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 448.38 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 180° | Oil-free | Resin | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 429.73 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | 10 | 0~1 | B | With one-touch fitting | 200 V AC | NBR | Standard | Oil-free | Resin | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 384.99 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 391.78 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | 90° | Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 377.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 200 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 421.97 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 396.09 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 409.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 200 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 408.72 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 472.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 460.88 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | 10 | 0~1 | B | With one-touch fitting | 220 V AC | NBR | Standard | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 377.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 421.97 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 396.09 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 450.59 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 426.91 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 465.69 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~0.7 | B | With one-touch fitting | 24 V DC | NBR | Standard | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | 10 | 0~1 | B | With one-touch fitting | 100 V AC | NBR | Standard | Oil-free | Resin | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 437.15 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 470.78 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 10 | 0~0.7 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | C37 | Included | Water | None | Grommet | ||
MYR 437.15 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 444.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet | ||
MYR 501.93 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 437.15 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 444.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 501.93 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 437.15 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 10 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy