SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 807.42 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 100 V AC | FKM | Standard | Oil-free | SUS | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 807.42 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.7 | B | None | 200 V AC | FKM | Standard | Oil-free | SUS | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 851.08 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.6 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 895.36 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 10 | 0~0.6 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | None | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 738.71 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 10 | 0~0.6 | H | None | 24 V DC | EPDM | Standard | Oil-free | C37 | Included | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 730.78 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.7 | H | None | 200 V AC | EPDM | Standard | Oil-free | C37 | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 879.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 10 | 0~0.6 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | Included | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 915.80 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 10 | 0~0.6 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 923.50 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.6 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | Included | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 801.73 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 10 | 0~0.6 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | Included | High temperature water | None | Grommet | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | None | Grommet | ||
MYR 737.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 635.21 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 727.63 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 798.58 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 657.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 705.24 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | C37 | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 657.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 799.32 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 687.08 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 688.11 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 180° | Oil-free | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 692.53 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 838.17 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 714.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 709.55 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | 90° | Oil-free | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 726.52 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,454.13 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | None | Grommet | ||
MYR 1,329.78 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | None | Grommet | ||
MYR 1,342.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | None | Grommet | ||
MYR 1,342.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | 270° | Oil-free | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,454.13 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,466.87 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,329.78 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,342.92 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | 270° | Oil-free | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,497.99 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,374.01 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 1,408.83 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,396.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,515.97 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,515.97 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,392.07 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,375.41 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,386.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,379.73 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | SUS | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 1,329.78 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | Oil-free | SUS | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 1,386.64 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 220 V AC | NBR | Standard | Oil-free | SUS | None | Air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,448.27 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,542.19 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,570.16 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,417.67 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,472.25 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,430.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,558.66 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,566.25 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,363.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 240 V AC | NBR | Standard | Oil-free | SUS | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 613.08 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet | ||
MYR 762.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 613.08 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 683.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 786.69 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 620.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Faston | ||
MYR 620.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Faston | ||
MYR 745.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Faston | ||
MYR 675.42 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 240 V AC | NBR | Standard | Oil-free | C37 | Included | Water | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 701.08 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 714.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,454.13 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | Grommet | ||
MYR 1,454.13 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,466.87 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,466.87 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,329.78 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,454.13 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,466.87 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,393.03 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,497.85 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,511.10 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,428.03 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | EPDM | IN side (standard) | Oil-free | SUS | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 1,392.07 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,515.97 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | G | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,378.82 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.6 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,513.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,503.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | NPT | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,390.98 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,420.22 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Open | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 100 V AC | EPDM | IN side (standard) | Oil-free | SUS | None | Water | None | DIN terminal (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy