SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,330.01 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | EPDM | 180° | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,330.01 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | EPDM | 270° | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,291.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,304.08 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,304.08 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,309.98 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,379.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,378.82 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,304.46 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | EPDM | IN side (standard) | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,291.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,304.08 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 90° | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,366.19 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,378.82 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,291.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,291.00 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,366.19 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,322.07 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | EPDM | Standard | Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,280.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,373.01 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,267.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,309.98 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | SUS | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,280.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 270° | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,267.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,355.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,267.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,298.49 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | 270° | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,355.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,286.25 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,280.86 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | SUS | Included | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,298.49 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | 270° | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,267.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | Oil-free | SUS | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,223.90 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 1,311.95 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 579.10 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet | ||
MYR 581.99 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 545.64 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | EPDM | IN side (standard) | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 516.02 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 528.81 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 581.99 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 516.02 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | EPDM | IN side (standard) | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 501.03 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 538.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 536.14 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 538.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 550.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 592.49 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | 180° | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 644.39 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 644.39 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 577.14 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 569.14 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 90° | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 556.46 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 543.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 631.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 230 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 639.01 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 652.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 90° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 652.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 652.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 270° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 559.77 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | 180° | Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 550.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 603.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~0.7 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 515.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 527.75 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 603.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 515.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | C37 | None | Water | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | C37 | Included | Water | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 550.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | 15 | 0~1 | B | None | 220 V AC | NBR | Standard | Oil-free | C37 | None | Water | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 626.41 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | Water | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 638.60 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | Water | Special voltage | DIN terminal (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy