SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Low noise construction
· Piping variations
· Clearance
· Improved armature durability
Part Number
Configured Part Number is shown.
| Valve Specifications | Valve Structure | Pilot operated 2 port diaphragm type | |
|---|---|---|---|
| Withstand Pressure | 2.0 MPa (resin body type: 1.5 MPa) | ||
| Body Material | Aluminum, resin, C37, SUS, CAC408 | ||
| Seal Materials | NBR, FKM, EPDM*3 | ||
| Enclosure | Dustproof, jetproof (IP65)*1, *4 | ||
| Environment | Locations without corrosive or explosive gases | ||
| Coil Specifications | Rated Voltage | AC | 100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*2 |
| DC | 24 V DC, (12 V DC)*2 | ||
| Allowable Voltage Fluctuation | ±10% of rated voltage | ||
| Allowable Leakage Voltage | AC | 5% or less of rated voltage | |
| DC | 2% or less of rated voltage | ||
| Coil Insulation Type | Class B, class H | ||
*1: Electrical entry "Faston" type terminal is IP40 compliant
*2 Voltage inside () indicates special voltage. (See the SMC catalog)
*3: See the catalog regarding seal material EPDM.
*4: See the SMC catalog glossary for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.

VXD23 diagram

VXD24 diagram

VXD25/26 diagram

VXD27/28/29 diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD23 | C37, SUS, Aluminum, resin (PBT) |
| VXD24 to 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 2 | Bonnet | VXD23/24 | SUS |
| VXD25, 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 3 | Diaphragm Assembly | VXD23 to 29 | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD23 to 29 | SUS |
| 5 | O-Ring | VXD23 to 26 | NBR, FKM, EPDM |
| 6 | Buffer | VXD23/24 | PPS |
| 7 | Stopper | VXD23 to 29 | NBR, FKM, EPDM |
| 8 | Armature Core | Fe | |
| 9 | Tube | SUS | |
| 10 | Spring | SUS | |
| 11 | Armature Assembly | SUS, NBR, FKM, EPDM, resin (PPS) | |
| 12 | Solenoid Coil | Cu + Fe + resin |
Operation

VXD2A diagram

VXD2B diagram

VXD2C/2D diagram

VXD2E, 2F, 2G diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD2A | C37, SUS, Aluminum, resin (PBT) |
| VXD2B to 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 2 | Bonnet | VXD2A, 2B | SUS |
| VXD2C, 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 3 | Diaphragm Assembly | VXD2A to 2G | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD2A to 2G | SUS |
| 5 | O-Ring | VXD2A to 2D | NBR, FKM, EPDM |
| 6 | Buffer | VXD2A, 2B | PPS |
| 7 | Sleeve Assembly | VXD2A to 2G | SUS, resin (PPS) |
| 8 | Push Rod Assembly | Resin (PPS), SUS, NBR, FKM, EPDM | |
| 9 | Spring | SUS | |
| 10 | O-Ring A | NBR, FKM, EPDM | |
| 11 | O-Ring B | NBR, FKM, EPDM | |
| 12 | Adapter | Resin (PPS) | |
| 13 | O-Ring C | NBR, FKM, EPDM | |
| 14 | Solenoid Coil | Cu + Fe + resin |
Operation
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Tube Flange Nominal | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 610.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 566.59 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 519.93 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | EPDM | Standard | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 586.64 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | EPDM | None | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 10 Day(s) or more | Water | 1/4 | Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 501.93 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 547.58 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | EPDM | 180° | Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 515.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 523.95 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | 90° | Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 558.78 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 566.59 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 533.18 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | EPDM | Standard | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 562.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | 180° | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 512.38 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 534.77 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | EPDM | Standard | Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 512.45 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 566.59 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 551.51 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 503.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 586.40 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | Standard | None | SUS | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 539.32 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.7 | B | None | 230 V DC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 220 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 494.11 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 240 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 484.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | SUS | None | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 496.66 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 484.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | SUS | None | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 480.89 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | SUS | None | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 610.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | Included | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 496.66 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | None | SUS | Included | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 535.70 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | SUS | None | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 547.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | Included | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 437.19 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | SUS | None | For water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 439.75 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | None | SUS | None | For water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 346.32 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet | ||
MYR 356.34 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet | ||
MYR 357.30 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | For oil | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | Oil-free | C37 | None | For oil | None | Grommet | ||
MYR 364.95 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | Oil-free | C37 | Included | For oil | None | Grommet | ||
MYR 346.32 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 358.83 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | Standard | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 377.25 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | 90° | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 377.25 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | 180° | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 369.93 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | 270° | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | Oil-free | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 200 V AC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 357.30 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 200 V AC | FKM | Standard | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 352.37 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 230 V DC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 389.24 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 428.82 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 401.13 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 406.40 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 406.40 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 419.03 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | 90° | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 395.02 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 407.47 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 460.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | 90° | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | Oil-free | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 414.16 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | Standard | Oil-free | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 406.40 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 200 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 406.40 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 200 V AC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 200 V AC | FKM | None | Oil-free | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 230 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 402.06 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 230 V DC | FKM | Standard | None | C37 | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 230 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 414.16 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 401.13 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | None | C37 | None | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 414.16 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | Standard | None | C37 | Included | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 441.73 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 230 V DC | FKM | None | None | C37 | None | For oil | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 362.62 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | None | None | C37 | None | For oil | None | Conduit (With surge voltage suppressor) | ||
MYR 377.69 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 100 V AC | FKM | Standard | None | C37 | Included | For oil | None | Conduit (With surge voltage suppressor) | ||
MYR 364.84 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | Conduit (With surge voltage suppressor) | ||
MYR 352.37 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 220 V AC | FKM | None | None | C37 | None | For oil | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 365.80 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 220 V AC | FKM | Standard | None | C37 | Included | For oil | Special voltage | Grommet (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy