[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Low noise construction
· Piping variations
· Clearance
· Improved armature durability
Part Number
Configured Part Number is shown.
| Valve Specifications | Valve Structure | Pilot operated 2 port diaphragm type | |
|---|---|---|---|
| Withstand Pressure | 2.0 MPa (resin body type: 1.5 MPa) | ||
| Body Material | Aluminum, resin, C37, SUS, CAC408 | ||
| Seal Materials | NBR, FKM, EPDM*3 | ||
| Enclosure | Dustproof, jetproof (IP65)*1, *4 | ||
| Environment | Locations without corrosive or explosive gases | ||
| Coil Specifications | Rated Voltage | AC | 100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*2 |
| DC | 24 V DC, (12 V DC)*2 | ||
| Allowable Voltage Fluctuation | ±10% of rated voltage | ||
| Allowable Leakage Voltage | AC | 5% or less of rated voltage | |
| DC | 2% or less of rated voltage | ||
| Coil Insulation Type | Class B, class H | ||
*1: Electrical entry "Faston" type terminal is IP40 compliant
*2 Voltage inside () indicates special voltage. (See the SMC catalog)
*3: See the catalog regarding seal material EPDM.
*4: See the SMC catalog glossary for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.

VXD23 diagram

VXD24 diagram

VXD25/26 diagram

VXD27/28/29 diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD23 | C37, SUS, Aluminum, resin (PBT) |
| VXD24 to 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 2 | Bonnet | VXD23/24 | SUS |
| VXD25, 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 3 | Diaphragm Assembly | VXD23 to 29 | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD23 to 29 | SUS |
| 5 | O-Ring | VXD23 to 26 | NBR, FKM, EPDM |
| 6 | Buffer | VXD23/24 | PPS |
| 7 | Stopper | VXD23 to 29 | NBR, FKM, EPDM |
| 8 | Armature Core | Fe | |
| 9 | Tube | SUS | |
| 10 | Spring | SUS | |
| 11 | Armature Assembly | SUS, NBR, FKM, EPDM, resin (PPS) | |
| 12 | Solenoid Coil | Cu + Fe + resin |
Operation

VXD2A diagram

VXD2B diagram

VXD2C/2D diagram

VXD2E, 2F, 2G diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD2A | C37, SUS, Aluminum, resin (PBT) |
| VXD2B to 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 2 | Bonnet | VXD2A, 2B | SUS |
| VXD2C, 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 3 | Diaphragm Assembly | VXD2A to 2G | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD2A to 2G | SUS |
| 5 | O-Ring | VXD2A to 2D | NBR, FKM, EPDM |
| 6 | Buffer | VXD2A, 2B | PPS |
| 7 | Sleeve Assembly | VXD2A to 2G | SUS, resin (PPS) |
| 8 | Push Rod Assembly | Resin (PPS), SUS, NBR, FKM, EPDM | |
| 9 | Spring | SUS | |
| 10 | O-Ring A | NBR, FKM, EPDM | |
| 11 | O-Ring B | NBR, FKM, EPDM | |
| 12 | Adapter | Resin (PPS) | |
| 13 | O-Ring C | NBR, FKM, EPDM | |
| 14 | Solenoid Coil | Cu + Fe + resin |
Operation
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Tube Flange Nominal | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 413.13 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 388.28 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 335.73 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 323.56 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 308.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 308.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 346.76 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | Aluminum | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 308.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | None | Oil-free | Aluminum | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 373.74 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.9 | B | None | 230 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 349.26 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 315.91 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | None | Oil-free | Aluminum | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 309.68 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | None | Conduit (With surge voltage suppressor) | ||
MYR 315.91 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 220 V AC | NBR | None | Oil-free | Aluminum | None | For air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 308.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 384.60 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 411.61 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 346.89 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 367.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 425.36 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | 180° | Oil-free | Aluminum | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 359.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | 90° | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 384.60 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | None | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 367.33 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 359.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | 180° | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 406.40 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 200 V AC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 377.06 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 220 V AC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 357.30 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 357.30 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 100 V AC | NBR | Standard | Oil-free | Aluminum | Included | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 359.57 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 24 V DC | NBR | 90° | Oil-free | Aluminum | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 311.10 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | Standard | Oil-free | Aluminum | Included | For air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 292.58 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.9 | B | None | 24 V DC | NBR | None | Oil-free | Aluminum | None | For air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 294.90 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | Grommet | ||
MYR 230.18 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | None | Grommet | ||
MYR 279.15 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 100 V AC | NBR | None | Oil-free | Resin | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 339.18 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 274.46 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 200 V AC | NBR | None | Oil-free | Resin | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 382.84 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 353.40 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 329.79 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø10 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 100 V AC | NBR | None | Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 294.90 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | Grommet | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 100 V AC | NBR | None | Oil-free | Resin | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 382.84 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | Ø9.52 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 326.84 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | Grommet | ||
MYR 256.23 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | None | Grommet | ||
MYR 232.22 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 200 V AC | NBR | None | Oil-free | Resin | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 348.75 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 352.37 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 287.36 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.9 | B | With one-touch fitting | 100 V AC | NBR | None | Oil-free | Resin | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 382.84 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 318.23 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | None | Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 378.00 | 1 Piece(s) | 23 Day(s) or more | Air | - | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | Tube Connection | ø12 | - | 10 | 0.02~0.7 | B | With one-touch fitting | 24 V DC | NBR | 270° | Oil-free | Resin | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 318.01 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | Grommet | ||
MYR 301.10 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | Grommet | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For water | None | Grommet | ||
MYR 402.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | For water | None | Grommet | ||
MYR 287.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | Grommet | ||
MYR 344.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | EPDM | Standard | Oil-free | C37 | None | For water | None | Grommet | ||
MYR 331.60 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For water | None | Grommet | ||
MYR 334.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 351.81 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 287.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 300.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 287.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | None | Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 300.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 287.09 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.7 | B | None | 230 V DC | NBR | None | Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 331.43 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 400.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 414.16 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 336.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 456.88 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 336.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 349.55 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 346.80 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 336.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | None | Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 384.60 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 371.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 230 V DC | NBR | None | Oil-free | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 450.51 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 357.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 379.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 401.73 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 417.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 317.61 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 340.49 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | None | Oil-free | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 320.78 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For water | None | Conduit (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy