(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Low noise construction
· Piping variations
· Clearance
· Improved armature durability
Part Number
Configured Part Number is shown.
| Valve Specifications | Valve Structure | Pilot operated 2 port diaphragm type | |
|---|---|---|---|
| Withstand Pressure | 2.0 MPa (resin body type: 1.5 MPa) | ||
| Body Material | Aluminum, resin, C37, SUS, CAC408 | ||
| Seal Materials | NBR, FKM, EPDM*3 | ||
| Enclosure | Dustproof, jetproof (IP65)*1, *4 | ||
| Environment | Locations without corrosive or explosive gases | ||
| Coil Specifications | Rated Voltage | AC | 100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*2 |
| DC | 24 V DC, (12 V DC)*2 | ||
| Allowable Voltage Fluctuation | ±10% of rated voltage | ||
| Allowable Leakage Voltage | AC | 5% or less of rated voltage | |
| DC | 2% or less of rated voltage | ||
| Coil Insulation Type | Class B, class H | ||
*1: Electrical entry "Faston" type terminal is IP40 compliant
*2 Voltage inside () indicates special voltage. (See the SMC catalog)
*3: See the catalog regarding seal material EPDM.
*4: See the SMC catalog glossary for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.

VXD23 diagram

VXD24 diagram

VXD25/26 diagram

VXD27/28/29 diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD23 | C37, SUS, Aluminum, resin (PBT) |
| VXD24 to 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 2 | Bonnet | VXD23/24 | SUS |
| VXD25, 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 3 | Diaphragm Assembly | VXD23 to 29 | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD23 to 29 | SUS |
| 5 | O-Ring | VXD23 to 26 | NBR, FKM, EPDM |
| 6 | Buffer | VXD23/24 | PPS |
| 7 | Stopper | VXD23 to 29 | NBR, FKM, EPDM |
| 8 | Armature Core | Fe | |
| 9 | Tube | SUS | |
| 10 | Spring | SUS | |
| 11 | Armature Assembly | SUS, NBR, FKM, EPDM, resin (PPS) | |
| 12 | Solenoid Coil | Cu + Fe + resin |
Operation

VXD2A diagram

VXD2B diagram

VXD2C/2D diagram

VXD2E, 2F, 2G diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD2A | C37, SUS, Aluminum, resin (PBT) |
| VXD2B to 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 2 | Bonnet | VXD2A, 2B | SUS |
| VXD2C, 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 3 | Diaphragm Assembly | VXD2A to 2G | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD2A to 2G | SUS |
| 5 | O-Ring | VXD2A to 2D | NBR, FKM, EPDM |
| 6 | Buffer | VXD2A, 2B | PPS |
| 7 | Sleeve Assembly | VXD2A to 2G | SUS, resin (PPS) |
| 8 | Push Rod Assembly | Resin (PPS), SUS, NBR, FKM, EPDM | |
| 9 | Spring | SUS | |
| 10 | O-Ring A | NBR, FKM, EPDM | |
| 11 | O-Ring B | NBR, FKM, EPDM | |
| 12 | Adapter | Resin (PPS) | |
| 13 | O-Ring C | NBR, FKM, EPDM | |
| 14 | Solenoid Coil | Cu + Fe + resin |
Operation
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Tube Flange Nominal | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,208.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 200 V AC | FKM | Standard | Oil-free | SUS | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,120.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | Included | For oil | None | Grommet | ||
MYR 1,110.38 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 100 V AC | FKM | None | Oil-free | SUS | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 1,110.38 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 200 V AC | FKM | None | Oil-free | SUS | None | For oil | None | Grommet (With surge voltage suppressor) | ||
MYR 1,205.88 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 15 | 0.02~0.7 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | Included | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,135.31 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 110 V AC | FKM | None | Oil-free | SUS | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,143.77 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 200 V AC | FKM | None | Oil-free | SUS | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,208.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~0.7 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,182.56 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 24 V DC | FKM | None | Oil-free | SUS | None | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,208.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 24 V DC | FKM | Standard | Oil-free | SUS | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,208.44 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | B | None | 100 V AC | FKM | Standard | Oil-free | SUS | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 507.36 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | C37 | None | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | C37 | None | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | C37 | None | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 564.21 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 200 V AC | EPDM | None | Oil-free | C37 | None | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 570.83 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | H | None | 110 V AC | EPDM | None | Oil-free | C37 | None | For high temperature water (99°C) | None | Conduit (With surge voltage suppressor) | ||
MYR 1,058.32 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | Standard | Oil-free | SUS | Included | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 1,218.80 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 24 V DC | EPDM | 180° | Oil-free | SUS | Included | For high temperature water (99°C) | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,032.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 1,032.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 1,058.32 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | Standard | Oil-free | SUS | Included | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 1,174.32 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 24 V DC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,185.76 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 24 V DC | EPDM | 180° | Oil-free | SUS | None | For high temperature water (99°C) | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,127.00 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 100 V AC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,103.75 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | H | None | 110 V AC | EPDM | Standard | Oil-free | SUS | Included | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,089.35 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 220 V AC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,179.67 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | H | None | 24 V DC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,217.37 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~1 | H | None | 200 V AC | EPDM | None | Oil-free | SUS | None | For high temperature water (99°C) | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 639.01 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | H | None | 100 V AC | FKM | None | Oil-free | C37 | None | For high temperature oil (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 603.00 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~0.7 | H | None | 110 V AC | FKM | None | Oil-free | C37 | None | For high temperature oil (99°C) | None | Conduit (With surge voltage suppressor) | ||
MYR 677.16 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~0.7 | H | None | 220 V AC | FKM | None | Oil-free | C37 | None | For high temperature oil (99°C) | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 646.10 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~0.7 | H | None | 110 V AC | FKM | None | Oil-free | C37 | None | For high temperature oil (99°C) | None | Conduit (With surge voltage suppressor) | ||
MYR 725.36 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | H | None | 24 V DC | FKM | None | Oil-free | C37 | None | For high temperature oil (99°C) | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,135.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~0.7 | H | None | 24 V DC | FKM | None | Oil-free | SUS | None | For high temperature oil (99°C) | None | Grommet | ||
MYR 1,135.96 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | H | None | 100 V AC | FKM | None | Oil-free | SUS | None | For high temperature oil (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 1,272.90 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | H | None | 100 V AC | FKM | None | Oil-free | SUS | None | For high temperature oil (99°C) | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,201.95 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 15 | 0.02~0.7 | H | None | 100 V AC | FKM | None | Oil-free | SUS | None | For high temperature oil (99°C) | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 544.02 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | None | Grommet | ||
MYR 685.50 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Grommet | ||
MYR 685.50 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 20 | 0.02~1 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Grommet | ||
MYR 546.21 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | None | Grommet | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | None | Grommet | ||
MYR 685.50 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 708.34 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 546.21 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 586.97 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | 90° | Oil-free | C37 | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 558.78 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | 180° | Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 546.21 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 110 V AC | NBR | None | Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 589.81 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 638.17 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 734.65 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 595.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 628.88 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 591.28 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 622.80 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 734.65 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 595.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 622.80 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 628.88 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 595.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 200 V AC | NBR | None | Oil-free | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 628.88 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 622.80 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 230 V DC | NBR | Standard | Oil-free | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 742.47 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 777.85 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | 90° | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 742.47 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 603.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 636.64 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 600.17 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | None | Conduit (With surge voltage suppressor) | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 220 V AC | NBR | Standard | Oil-free | C37 | Included | For air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 579.73 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 12 V DC | NBR | Standard | Oil-free | C37 | Included | For air | Special voltage | Grommet | ||
MYR 628.88 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 220 V AC | NBR | Standard | Oil-free | C37 | Included | For air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 566.59 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 220 V AC | NBR | None | Oil-free | C37 | None | For air | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 606.61 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 630.72 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | G | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 634.03 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | None | Oil-free | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 13 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 720.61 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | 90° | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 634.03 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 110 V AC | NBR | Standard | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 667.67 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 657.13 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | None | Oil-free | C37 | None | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 657.13 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | Included | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 803.80 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 20 | 0.02~1 | B | None | 110 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 697.03 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 200 V AC | NBR | Standard | Oil-free | C37 | Included | For air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 709.12 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | [Rc (R)] Rc | - | - | 20 | 0.02~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy