Analog output (voltage). Compact Pneumatic Pressure Sensor PSE540 Series.
[Features]
· Manifolding is possible.
· Pads can be directly mounted.
Part Number
Configured Part Number is shown.
PSE541A-M5-C2

Compact Pneumatic Pressure Sensor PSE540 Series product image

Model number example
| Model | PSE540 | PSE541 | PSE543 | |
|---|---|---|---|---|
| Rated pressure range | 0 to 1 MPa | 0 to -101 kPa | -100 to 100 kPa | |
| Extended analog output range | -0.1 to 0 MPa | 10.1 to 0 kPa | - | |
| Pressure resistance | 1.5 MPa | 500 kPa | ||
| Applicable fluid | Air / Non-corrosive gas / Non-combustible gas | |||
| Power supply voltage | 12 to 24 V DC ±10%, Ripple (p-p) 10% or less (with reverse connection protection) | |||
| Current Consumption | 15 mA or less | |||
| Output specifications | Analog output 1 to 5 V (within rated pressure range), 0.6 to 1 V (within extended analog output range), Output impedance: Approx. 1 kΩ | |||
| Accuracy (ambient temperature of 25°C) | PSE54□: ±2% F.S. (within rated pressure range), ±5% F.S. (within extended analog output range) PSE54□A: ±1% F.S. (within rated pressure range), ±3% F.S. (within extended analog output range) | |||
| Linearity | ±0.7% F.S. or less | ±0.4% F.S. | ||
| Repeat accuracy | ±0.2% F.S. | |||
| Power supply voltage effect | ±0.8% F.S. | |||
| Environmental resistance | Enclosure | IP40 | ||
| Operating temperature range | During operation: 0 to 50°C, During storage: -20 to 70°C (No condensation or freezing) | |||
| Operating Humidity Range | During operation, storage: 35 to 85% RH (No condensation) | |||
| Withstand Voltage | 1,000 V AC 50/60 Hz for 1 min. between terminals and housing | |||
| Insulation Resistance | 50 MΩ or more (500 V DC, measured via megohmmeter) between terminals and housing | |||
| Temperature characteristics | ±2% F.S. (25°C reference) | |||
| Sensor cable | Oilproof heavy-duty vinyl cable (ellipse) 3 cores, 2.7 × 3.2, 3 m, Conductor area: 0.15 mm2 Insulator O.D.: 0.9 mm | |||
| Standard | CE UL/CSA (E216656) | |||
| Part number | M3 | M5 | 01 | N01 | R04 | R06 | IM5 | IM5H | |
|---|---|---|---|---|---|---|---|---|---|
| Piping connection port diameter | M3 × 0.5 | M5 × 0.8 | R1/8 M5 × 0.8 | NPT1/8 M5 × 0.8 | ø4 (4‑mm diameter) reducer | ø6 (6‑mm diameter) reducer | M5 female thread, through type | M5 female thread, through type (with mounting hole) | |
| Material | Case | Resin case: PBT Fitting: SUS303 | Resin case: PBT Fitting: C3604BD | PBT | Resin case: PBT Fitting: A6063S-T5 | ||||
| Pressure sensing section | Pressure sensor: Silicon, O-ring: NBR | ||||||||
| Weight | With sensor cable | 42.4 g | 42.7 g | 49.3 g | 41.4 g | 41.6 g | 43.3 g | 44.1 g | |
| Without sensor cable | 2.9 g | 3.2 g | 9.8 g | 1.9 g | 2.1 g | 3.8 g | 4.6 g | ||

PSE54□

1 to 5 V DC
| Range | Rated pressure range | A | B | C |
|---|---|---|---|---|
| For vacuum pressure | 0 to -101 kPa | 0 | -101 kPa | 10.1 kPa |
| For compound pressure | -100 kPa to 100 kPa | -100 kPa | 100 kPa | - |
| For positive pressure | 0 to 1 MPa | 0 | 1 MPa | -0.1 MPa |
(Unit: mm)

PSE54□-01/PSE54□-N01 dimensional drawing
(Unit: mm)

PSE54□-R04/PSE54□-R06 dimensional drawing
| - | PSE54□-R04 | PSE54□-R06 |
|---|---|---|
| A | ø4 (diameter 4 mm) | ø6 (diameter 6 mm) |
| B | 18 | 20 |
| Part Number |
|---|
| PSE541A-M5-C2 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Pipe Port Type | Plumbing Thread Type | Plumbing Thread Nominal | Pressure Resistant (MPa) | Operating Temperature Range (°C) | Connecting Tube Diameter | Application | Option | Accuracy (%F.S.) | Female thread compatible |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 319.10 | 1 Piece(s) | 14 Day(s) or more | [Threads] Male thread | M | M5x0.8 | 0.5 | - | - | Negative pressure [0 to −101 kPa] | Connector for pressure sensor controller 1 pc. | ±1 | - |
Loading...
| Type | Pressure Sensor | Fluid Type | Air | Sensor, Monitor Structure | Separated sensor |
|---|---|---|---|---|---|
| Output Method | Analog | Analog Output Specification | Voltage | Fluid Characteristics | Noncorrosive / Incombustible |
| Operating Humidity Range(%) | 35::85 | Number of Input Points | 1 | Number of Output Points | 1 |
| Power Supply Type | DC | Power Supply Voltage(V) | 12 to 24 ±10% | Pipe Connection Direction | Down |
| Display | No | Lamp | No | Acquired Standards | CE |
| Protection Structure | IP40 | Analog Voltage Output(V) | 1 to 5 V DC |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy