(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Low Power Consumption Soft Start-Up Valve AV2000/3000/4000/5000 Series
[Features]
・ A low-speed air supply that gradually raises the initial pressure of the pneumatic system, and a start valve that shuts off the air supply and enables rapid exhaust.
・ With air supply / exhaust function by manual operation
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Regulator Unit Combination | Connection Dia. | Compressed Air Quality | Max. Operating Pressure (MPa) | Flow Direction | Pressure Gauge | Size of Body | Coil rated voltage | Lead wire electrical entry | Protection circuit | Manual operation | CE compliant | Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 869.38 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 110 to 120 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 869.38 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Type D DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 869.38 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Type D DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 861.50 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Type D DIN terminal (without connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 829.99 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Grommet | None | Locking type (lever) | Non-compatible | - | ||
MYR 853.57 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 853.57 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Grommet | Surge | Locking type (lever) | Non-compatible | - | ||
MYR 869.38 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 869.38 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 24 V DC | Type Y DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 893.01 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 30 | 12 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 100 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 953.96 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type D DIN terminal (without connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Non-compatible | - | ||
MYR 981.95 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Compatible | - | ||
MYR 898.81 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Grommet | None | Locking type (lever) | Non-compatible | - | ||
MYR 922.44 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 938.20 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type Y DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 24 V DC | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 961.83 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | NPT3/8 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 30 | 12 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 100 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 978.16 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 100 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Compatible | - | ||
MYR 918.71 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 100 V AC (50/60 Hz) | Grommet | Surge | Locking type (lever) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 100 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 100 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 200 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 978.16 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 200 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Compatible | - | ||
MYR 895.07 | 1 Piece(s) | 18 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 200 V AC (50/60 Hz) | Grommet | None | Locking type (tool required) | Non-compatible | - | ||
MYR 918.71 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 200 V AC (50/60 Hz) | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 200 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 895.07 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Grommet | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 918.71 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Grommet | Surge | Locking type (tool required) | Non-compatible | - | ||
MYR 926.58 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 110 to 120 V AC (50/60 Hz) | Type Y DIN terminal (without connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 895.07 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Grommet | None | Locking type (lever) | Non-compatible | - | ||
MYR 918.71 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 918.71 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Grommet | Surge | Locking type (lever) | Non-compatible | - | ||
MYR 937.00 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 220 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 946.65 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type D DIN terminal (without connector) | None | Non-locking push type (flush) | Compatible | - | ||
MYR 1,071.58 | 1 Piece(s) | 3 Day(s) | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,094.45 | 1 Piece(s) | 3 Day(s) | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Compatible | - | ||
MYR 1,071.58 | 1 Piece(s) | 3 Day(s) | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Non-compatible | - | ||
MYR 999.02 | 1 Piece(s) | 3 Day(s) | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Grommet | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 895.07 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Grommet | None | Locking type (lever) | Non-compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type Y DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 954.53 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type Y DIN terminal (with connector) | None | Locking type (lever) | Compatible | - | ||
MYR 978.16 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Compatible | - | ||
MYR 978.16 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | No (No Pressure Port Plug) | 40 | 24 V DC | Type Y DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Compatible | - | ||
MYR 934.51 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 12 V DC | Type D DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 12 V DC | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 895.07 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 12 V DC | Grommet | None | Locking type (tool required) | Non-compatible | - | ||
MYR 957.03 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 240 V AC 50/60 Hz | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | 240 V AC 50/60 Hz | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 958.15 | 1 Piece(s) | 18 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | - | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Non-compatible | - | ||
MYR 946.65 | 1 Piece(s) | 18 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | No (No Pressure Port Plug) | 40 | - | Type Y DIN terminal (without connector) | None | Non-locking push type (flush) | CE-compliant product | - | ||
MYR 987.53 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 100 V AC (50/60 Hz) | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 987.53 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 100 V AC (50/60 Hz) | Grommet | Surge | Locking type (lever) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 200 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 1,026.97 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 200 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 963.84 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 200 V AC (50/60 Hz) | Grommet | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 987.53 | 1 Piece(s) | 18 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 200 V AC (50/60 Hz) | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,026.97 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 110 to 120 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (tool required) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 220 V AC (50/60 Hz) | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,026.97 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 220 V AC (50/60 Hz) | Type D DIN terminal (with connector) | Indicator light, surge voltage suppressor | Locking type (lever) | Non-compatible | - | ||
MYR 963.84 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 220 V AC (50/60 Hz) | Grommet | None | Locking type (tool required) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 220 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 220 V AC (50/60 Hz) | Type Y DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Non-compatible | - | ||
MYR 1,023.35 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (with connector) | None | Non-locking push type (flush) | Compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (with connector) | None | Locking type (tool required) | Non-compatible | - | ||
MYR 1,003.28 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (with connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 995.35 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (without connector) | None | Locking type (lever) | Non-compatible | - | ||
MYR 1,019.09 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Type D DIN terminal (without connector) | Indicator light, surge voltage suppressor | Non-locking push type (flush) | Non-compatible | - | ||
MYR 963.84 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Grommet | None | Locking type (lever) | Non-compatible | - | ||
MYR 987.53 | 1 Piece(s) | 18 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Reverse Flow (Right to Left)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Grommet | Surge | Non-locking push type (flush) | Non-compatible | - | ||
MYR 987.53 | 1 Piece(s) | 14 Day(s) or more | [Other FRL Combination Devices] Soft Start-Up Valve | Rc1/2 | General Dry Air | 1 | [Standard Flow (Left to Right)] Flow Direction | [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator) | 40 | 24 V DC | Grommet | Surge | Locking type (tool required) | Non-compatible | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy