Flame Retardant (Equivalent To UL-94 Standard V-0) FR Soft Nylon Tubing TRS Series (TRS1065BU-100)

Flame Retardant (Equivalent To UL-94 Standard V-0) FR Soft Nylon Tubing TRS Series TRS1065BU-100

Flame-retardant tubing.
[Features]
· Maximum operating pressure 1.2 MPa or less (at 20°C)
· For use in environments where spatter may occur / Flame retardant (equivalent to UL-94 standard V-0)
[Applications]
· Suitable for air and water piping in environments with sparks from spot welders, etc.

(i)Caution

  • For specifications and details, please refer to the catalog.
  • Product pictures are representations.

PDF

Part Number

Configured Part Number is shown.

TRS1065BU-100

Specifications of Flame Retardant (Equivalent to UL-94 Standard V-0) FR Soft Nylon Tubing TRS Series

Maximum operating pressure

Maximum operating pressure

Series List

NominalTRS0603TRS0805TRS1065TRS1208
Outer diameter (mm)681012
Inner diameter (mm)356.58

Specifications

FluidAir, water
Maximum operating pressure (MPa)20°C1.2
40°C1.2
60°C0.7
Applicable fittingsFR One-touch Fittings KR-W2 Series
Minimum bending radius mm17192732
Operating temperature-20 to +60°C, Water: 0 to 60°C (No freezing)
MaterialFlame-retardant nylon (equivalent to UL-94 standard V-0)

Caution

  • 1. Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Also, the surge pressure must not exceed the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.
  • 2. Abnormal temperature rise caused by adiabatic compression may result in the tube bursting.
Part Number
TRS1065BU-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOuter Dia. D
(Ø)
Inner Dia. d
(Ø)
Color Outer Diameter [Category] I.D. [Category] Min. Bend Radius
(mm)
Bundle winding length
(m)
Reel winding length
(m)

MYR 2,366.86

1 Piece(s) 14 Day(s) or more 106.5[Blue] Blue (opaque)Up to 10~727-100

Loading...

  1. 1
 

Basic Information

Material Polyolefinic Resin Applicable Fluid Water / Air Type Straight
Operating Environment Standard Cutting Service Availability No Material: Nylon Flame Retardant Nylon(UL-94Std. V-0 Equivalent)
Maximum operating pressure(MPa) 1.2 (at 20°C) Operating temperature(°C) -20 to +60, With Water: 0 to +60 (Do Not Freeze)

Additional Products in this Category

Tech Support