A standard type valve mounted double action, single rod cylinder.
[Features]
· An air cylinder with a valve mounted on the round cylinder.
· Cylinder with valve that makes it easy to adjust speed.
*See the SMC catalog for specification details.
*Product pictures are representative images. CAD data is not supported for some model numbers.
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Cylinder (Tube) Inner Diameter (Ø) | Stroke (mm) | Main Body Shape | Additional Function | Type | Specifications | Port thread type | Auto Switches | Lead Wire | The number of the switches | Type of Mount Support | Bellows | Custom-made Specifications | Type | Energized push/pull | Solenoid valve | Solenoid valve voltage | Lead wire electrical entry | Indicator light / Surge voltage suppressor | Connector type | Auto switch mounting bracket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 908.80 | 1 Piece(s) | 27 Day(s) or more | 20 | 175 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | L plug connector | No | - | - | ||
MYR 900.97 | 1 Piece(s) | 27 Day(s) or more | 20 | 175 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | With surge voltage suppressor | - | - | ||
MYR 897.36 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 928.92 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 897.36 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,133.84 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position double | 24 V DC | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 897.36 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 897.36 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 908.80 | 1 Piece(s) | 27 Day(s) or more | 20 | 200 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 24 V DC | L plug connector | No | - | - | ||
MYR 936.80 | 1 Piece(s) | 27 Day(s) or more | 20 | 205 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 932.49 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | L plug connector | No | - | - | ||
MYR 952.50 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 920.99 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,212.67 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position double | 24 V DC | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 964.00 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 220 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 1,220.60 | 1 Piece(s) | 27 Day(s) or more | 20 | 250 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | L plug connector | No | - | - | ||
MYR 944.67 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,181.16 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position double | 24 V DC | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 956.12 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 24 V DC | L plug connector | No | - | - | ||
MYR 1,283.63 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 12 V DC | Grommet | With surge voltage suppressor | - | - | ||
MYR 1,315.24 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 1,379.00 | 1 Piece(s) | 27 Day(s) or more | 20 | 300 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Heat-resistant tarpaulin | None | Built-in one-touch fittings | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 968.31 | 1 Piece(s) | 27 Day(s) or more | 20 | 350 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,027.07 | 1 Piece(s) | 27 Day(s) or more | 20 | 350 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 24 V DC | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 979.80 | 1 Piece(s) | 27 Day(s) or more | 20 | 375 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 991.94 | 1 Piece(s) | 27 Day(s) or more | 20 | 380 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,003.44 | 1 Piece(s) | 27 Day(s) or more | 20 | 400 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 991.94 | 1 Piece(s) | 27 Day(s) or more | 20 | 400 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 1,050.75 | 1 Piece(s) | 27 Day(s) or more | 20 | 400 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Built-in one-touch fittings | Retracted when energized | 2 position single | 24 V DC | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 814.22 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 822.76 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 843.37 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | L plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 10 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 843.37 | 1 Piece(s) | 27 Day(s) or more | 25 | 18 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 842.16 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 835.57 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | DIN terminal | No | - | - | ||
MYR 857.64 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 20 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 834.33 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 848.70 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 870.22 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 890.88 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | With powerful scraper | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 843.37 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | L plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 807.69 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 110 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 220 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 831.60 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 1,078.70 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position double | 200 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 998.87 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position double | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 1,077.41 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | With powerful scraper | Screw-in piping type | Extended when energized | 2 position double | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 857.64 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 794.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 870.22 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 806.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 843.37 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Retracted when energized | 2 position single | 200 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 1,031.37 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 977.07 | 1 Piece(s) | 27 Day(s) or more | 25 | 25 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 862.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 26 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 807.30 | 1 Piece(s) | 27 Day(s) or more | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 897.36 | 1 Piece(s) | 27 Day(s) or more | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | With powerful scraper | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 819.93 | 1 Piece(s) | 27 Day(s) or more | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 902.59 | 1 Piece(s) | 27 Day(s) or more | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | With powerful scraper | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
MYR 807.30 | 1 Piece(s) | 27 Day(s) or more | 25 | 30 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 35 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 1,039.26 | 1 Piece(s) | 27 Day(s) or more | 25 | 40 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | Nylon tarpaulin | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 849.72 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 807.30 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 844.51 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 100 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 862.34 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | DIN terminal | No | - | - | ||
MYR 819.93 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | No | - | - | ||
- | 1 Piece(s) | Quote | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | Grommet | With surge voltage suppressor | - | - | ||
MYR 835.39 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | M plug connector | No | - | - | ||
MYR 856.96 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 200 V AC (50/60 Hz) | M plug connector | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 848.56 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | DIN terminal | No | - | - | ||
MYR 871.23 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | DIN terminal | With light and surge voltage suppressor (excluding G) | - | - | ||
MYR 807.30 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | No | - | - | ||
MYR 823.84 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position single | 24 V DC | Grommet | With surge voltage suppressor | - | - | ||
MYR 1,011.32 | 1 Piece(s) | 27 Day(s) or more | 25 | 50 | Standard | Standard | - | Without magnet | Rc | - | - | - | Basic type | None | None | Screw-in piping type | Extended when energized | 2 position double | 200 V AC (50/60 Hz) | Grommet | No | - | - |
Loading...
| Rod Operation Method | Single Rods | Cylinder Operation Method | Double Acting | Environment, Applications | Standard |
|---|---|---|---|---|---|
| End Locking | No | Valves | Presence | Cushion | Rubber cushion |
| Operating Pressure(MPa) | 0.15 to 0.7 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy