(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A fluoropolymer fitting with an integrated fitting construction.
[Features]
· Fluid adjustment range: 0 to 12 l/min.
· Integrated fitting construction: Hyper fitting, LQ2 series is used.
· Triple-seal construction.
· Nut locking mechanism.
· High flexural strength.
· Different tubing sizes can be selected.
· Material: New PFA.
Part Number
Configured Part Number is shown.

LVN Series External Appearance

LVN Series Dimensional Drawing
| Model | A | B | C | D | E | F | G | H | J | K | S |
|---|---|---|---|---|---|---|---|---|---|---|---|
| LVN20 | 48 | 24 | 12 | 88 | 34.5 | 6 | 4 | 14 | 20 | 18 | 2.4 |
| LVN30 | 60 | 30 | 18 | 110 | 43 | 9 | 5 | 25 | 26 | 24 | 7.5 |
| LVN40 | 72 | 36 | 22 | 124 | 52 | 11 | 6 | 25 | 33 | 30 | 8 |
Unit: mm

LVN Series Structural Drawing
| No. | Part Name | Material |
|---|---|---|
| 1 | Body | PFA |
| 2 | Needle | PCTFE |
| 3 | V seal | PTFE |
| 4 | Lock nut | PVDF |
| 5 | Adjustment handle | PVDF |
| 6 | Insert bushing | PFA |
| 7 | Nut | PFA |
| 8 | Collar | PFA |
| Model | LVN20 | LVN30 | LVN40 | |||
|---|---|---|---|---|---|---|
| Tube outer diameterNote) | mm | 4, 6 | 6, 8, 10 | 10, 12 | ||
| Inch | 1/8 ", 3/16 ", 1/4 " | 1/4 ", 3/8 " | 3/8 ", 1/2 " | |||
| Orifice diameter | ø4.4 | ø8 | ø10 | |||
| Flow rate characteristics | Av × Kv | 0.4 | 1.2 | 1.8 | ||
| Cv | 0.5 | 1.4 | 2.2 | |||
| Withstand pressure (MPa) | 1 | |||||
| Operating pressure (MPa) | 0 to 0.5 | |||||
| Fluid temperature (°C) | 5 to 90 | |||||
| Ambient temperature (°C) | 0 to 60 | |||||
| Weight (kg) | 0.055 | 0.115 | 0.185 | |||
Note) For details of the applicable tubing sizes, refer to page 945.
Different diameter tubing can be selected (within a body class) by using a nut and insert bushing (reducer). Applicable fitting: LQ2.
| Body class | Connection tube outer diameter | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Metric Size | Inch Size | |||||||||
| 4 | 6 | 8 | 10 | 12 | 1/8 " | 3/16 " | 1/4 " | 3/8 " | 1/2 " | |
| 2 | ● | ○ | - | - | - | ● | ● | ○ | - | - |
| 3 | - | ● | ● | ○ | - | - | - | ● | ○ | - |
| 4 | - | - | - | ● | ○ | - | - | - | ● | ○ |
○ Basic size/● With reducer
Note) Refer to page 910 for information on changing tubing sizes.

LVN20 flow rate characteristics

LVN30 flow rate characteristics

LVN40 flow rate characteristics
Caution) Because the LVN series cannot be used as a stop valve the flow rate will not be "0" when the number of needle rotations is "0." For details, refer to p. 945 in the catalog, "Precautions."

Examples of special tool use when connecting tubing
1. Use special tools to connect tubing.
| Body class | Torque (N⋅m) |
|---|---|
| 2 | 1.5 to 2.0 |
| 3 | 3.0 to 3.5 |
| 4 | 7.5 to 9.0 |
2. Tighten the nut until it touches the end surface of the body, and then tighten it an additional 1/8 turn to ensure that the nut has reached the end surface. If the nut will not turn any further, then it means a sufficient tightening has occurred. Refer to the appropriate tightening torques for piping shown to the left.
| Part Number |
|---|
| Part Number | Minimum order quantity | Volume Discount | Days to Ship | Type | Compatible Tube O.D. (mm) D (D1) | Compatible Tube O.D. (mm) D2 | Compatible Tube O.D. (inch) D (D1) | Compatible Tube O.D. (inch) D2 | Tube Size Standard | Size of Body |
|---|
Loading...
| Main Body Material | PFA | Related Part Type | Other |
|---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy