(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
The new M3GB1/2/M4GB1 to 3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
Japanese Only
| Part Number |
|---|
| 4GB119R-00-7 |
| 4GB119R-00-[E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB129R-00-7 |
| 4GB129R-00-[E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB139R-00-7 |
| 4GB139R-00-[E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB149R-00-7 |
| 4GB149R-00-[E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB219R-00-7 |
| 4GB219R-00-[B,BN,E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB229R-00-7 |
| 4GB229R-00-[B,BN,E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB239R-00-7 |
| 4GB239R-00-[B,BN,E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB319R-00-7 |
| 4GB319R-00-[B,BN,E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| 4GB329R-00-7 |
| 4GB329R-00-[B,BN,E00,E01J,E01,E02J,E02,E03J,E03,E0N,E0,E1,E2N,E2,E3,E20,E21J,E21,E22J,E22,E23J,E23]-7 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number of Solenoids | Switching Type | Status at Power Off | Voltage | Applicable Cylinder Dia. (Ø) | Connection Diameter | Electrical Wiring Connection |
|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 12 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 12 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J | ||
- | 1 Piece(s) | 12 Day(s) or more | Double | [3-Position Closed Center] 3 Position All Ports Blocked | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 12 Day(s) or more | Double | [3-Position Closed Center] 3 Position All Ports Blocked | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 3 Position A · B · R Connection | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 3 Position A · B · R Connection | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / DC5V / DC3V | 20 to 40 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J | ||
- | 1 Piece(s) | 20 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 20 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | [3-Position Closed Center] 3 Position All Ports Blocked | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 13 Day(s) or more | Double | [3-Position Closed Center] 3 Position All Ports Blocked | [Self-Recovery (Spring Return)] Self-reset(spring return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 40 to 80 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN | ||
- | 1 Piece(s) | 13 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 63 to 100 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 13 Day(s) or more | Single | 2-position exhaust | Self-reset(differential pressure return) | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 63 to 100 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN | ||
- | 1 Piece(s) | 12 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 63 to 100 | For single valve unit to be equipped to the base | Grommet Lead Wire | ||
- | 1 Piece(s) | 12 Day(s) or more | Double | 2-position exhaust | Self-holding | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | 63 to 100 | For single valve unit to be equipped to the base | E0 / E00 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN |
Loading...
| Type | Electromagnetic Valve | Application | Unit for manifold | Number of Ports | 5-port valve |
|---|---|---|---|---|---|
| Mounting Orientation | Manifold Base | Specifications | Standard / Oil-Free | Pipe Port Type | No port specified |
| Plumbing | Subbase Plumbing | Driving Type | Pilot-operated Spool | Seal Type | Soft seal |




CKD
Days to Ship : 12 Day(s) or more


CKD
Days to Ship : 13 Day(s) or more


KOGANEI
Standard Price : MYR 172.15-
Days to Ship : 4 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy