(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Best selling, compact, multi-contact with variety of variations
Part Number
Configured Part Number is shown.


Note 1. Limit Switch, The dimensional tolerance of parts not specified in the above external dimension diagrams for each model is ±0.4 mm.
2. There is variation in the simultaneity of the ON/OFF action of contacts with 2 or more poles (2NC, 2NC/1NO, 3NC), so please check before use.

| Interlock Type of Limit Switch | Type 2 (EN ISO 14119) | |
|---|---|---|
| Coding Level | Low level coded (EN ISO 14119) | |
| Protective structure*1 | IP67 (EN60947-5-1) | |
| Durability*2 | Mechanical | Over 1 million times |
| Electrical | 500,000 times or more (AC250V 3A, with resistive load) *3 | |
| Allowable Operating Speed | 0.05 to 0.5 m/s | |
| Permitted operation frequency | Maximum 30 times/min | |
| Direct opening action*4 | Minimum 60N (EN60947-5-1) | |
| Direct opening movement*4 | Minimum 10mm (EN60947-5-1) | |
| Lock strength (Fzh) *5 | Minimum 1,300N | |
| Contact Resistance | 25mΩ or less (per contact) | |
| Minimum applicable load*6 | DC5V 1mA resistive load (N level reference value) | |
| Rated insulation voltage (Ui) | 300V (EN60947-5-1) | |
| Rated Frequency | 50/60Hz | |
| Electric shock protection class | Class II (double insulated)![]() | |
| Pollution level (usage environment) | Pollution degree 3 (EN60947-5-1) | |
| Impulse withstand voltage (Uimp) (EN60947-5-1) | Between same-polarity terminals | 2.5kV |
| Between different terminals | 4kV | |
| Between each terminal and non-current-carrying metal parts | 6kV | |
| Insulation resistance | 100MΩ or more (at DC500V mega) | |
| Contact Gap | Minimum 2 x 2 mm | |
| vibration | malfunction | 10 to 55Hz, single amplitude 0.75mm |
| impact | Durability | 1,000m/s2 ormore |
| malfunction | 100m/s2 ormore | |
| Conditional Short Circuit Current | 100A (EN60947-5-1) | |
| Rated open thermal current (Ith) | 10A (EN60947-5-1) | |
| Ambient temperature | -10 to +55℃ (but do not freeze) | |
| Ambient humidity | 95% RH or less | |
| mass | Approx. 370g (D4NL-1AFA-B) | |
Note 1. The above values ​​are initial values of Limit Switch.
2. The switch contacts are compatible with both normal and micro loads, but once a load has been opened or closed, a load with a smaller capacity cannot be connected to the contacts. Otherwise,
the contact surface may become rough and the contact reliability may be impaired.
*1. This protective structure is based on a test method based on the standard (EN60947-5-1), and the sealability under the actual usage environment and conditions should be confirmed in advance.
The switch box body is protected from the intrusion of dust and water, but the operation key insertion port in the head part should not be exposed to cutting chips, water, chemicals, etc. This
may cause early wear, damage, and failure of Limit Switch.
*2. The durability conditions are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. Do not apply AC250V 3A to two or more circuits.
*4. Please ensure this for safe use.
*5. Based on the evaluation method of EN ISO14119.
*6. This value may change depending on the switching frequency, environmental conditions, reliability level, etc. Please check with the actual load in advance.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Detector Shape | Plunger Shape Type | Acquired Standards | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Contact Type | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Conduit Size | Details Type | Contact format | Release Key Type | Lock / Release System | Built-in Switch Specification | Head Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 600.59 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 1NC/1NO+1NC/1NO | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 643.08 | 1 Piece(s) | 2 Day(s) | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 1NC/1NO+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 682.71 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 1NC/1NO+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 732.25 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 1NC/1NO+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 600.59 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 2NC+1NC/1NO | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 551.36 | 1 Piece(s) | 5 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC+1NC/1NO | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 743.26 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 2NC+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 571.53 | 1 Piece(s) | 18 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC+1NC/1NO | Special release key (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 682.71 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 2NC+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 705.85 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | - | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 693.71 | 1 Piece(s) | 23 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | - | General type (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 732.25 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 2NC/2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 566.51 | 1 Piece(s) | 9 Day(s) or more | - | - | UL / CE / GB(CCC) / CSA | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC+2NC | General type (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 738.85 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | - | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 611.04 | 1 Piece(s) | 5 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC/1NO+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 565.21 | 1 Piece(s) | 9 Day(s) or more | - | - | UL / CE / GB(CCC) / CSA | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC/1NO+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 611.04 | 1 Piece(s) | 14 Day(s) or more | - | - | UL / CE / GB(CCC) / CSA | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 2NC/1NO+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 576.43 | 1 Piece(s) | 14 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 3NC+1NC/1NO | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 577.81 | 1 Piece(s) | 9 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 3NC+1NC/1NO | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 599.78 | 1 Piece(s) | 9 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 3NC+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 738.85 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | - | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 577.81 | 1 Piece(s) | 9 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | Pg13.5 | Standard type | 3NC+2NC | Special release key (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 785.88 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | Pg13.5 | Caster | 3NC+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 647.66 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 1NC/1NO+1NC/1NO | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 619.91 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 1NC/1NO+1NC/1NO | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 681.05 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 643.08 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 1NC/1NO+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 660.01 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 730.60 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 600.59 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 1NC/1NO+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 551.36 | 1 Piece(s) | 5 Day(s) or more | - | - | UL / CE / GB(CCC) / CSA | - | - | - | - | - | - | - | - | G1/2 | Standard type | 1NC/1NO+2NC | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 1NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 643.08 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 1NC/1NO+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 1NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 682.71 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC+1NC/1NO | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 551.36 | 1 Piece(s) | 5 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | G1/2 | Standard type | 2NC+1NC/1NO | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 643.08 | 1 Piece(s) | 2 Day(s) | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 600.59 | 1 Piece(s) | 2 Day(s) | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 619.91 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC/2NC | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 621.31 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 682.71 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 643.08 | 1 Piece(s) | 2 Day(s) | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC/2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 681.05 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 738.85 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 784.25 | 1 Piece(s) | 14 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 650.88 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC/1NO+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 577.81 | 1 Piece(s) | 9 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | G1/2 | Standard type | 2NC/1NO+2NC | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 768.08 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 740.50 | 1 Piece(s) | 14 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 785.88 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 2NC/1NO+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 800.80 | 1 Piece(s) | 14 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 607.36 | 1 Piece(s) | 9 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | G1/2 | Standard type | 2NC/1NO+2NC | General type (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 2NC/1NO (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 738.85 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 755.40 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 785.88 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 3NC+1NC/1NO | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 1NC/1NO (Slow-action) | Plastic | ||
MYR 740.50 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Top, Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 3NC+2NC | General type (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 755.40 | 1 Piece(s) | 14 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | Special release key (Resin) / Bottom | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 740.50 | 1 Piece(s) | 5 Day(s) or more | - | - | TUV / UL / C-UL / CE / GB(CCC) / EN | - | - | - | - | - | - | - | - | G1/2 | Standard type | - | General type (Resin) / Front | Mechanical Lock System / 24 V DC Solenoid Release Method | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 689.50 | 1 Piece(s) | 5 Day(s) or more | Plunger Type | [Top Plunger] Panel Mounted Plunger | TUV / UL / C-UL / CE / GB(CCC) / CQC / CSA / EN | 15 | 9 | Mutual insulation double-throw | DC125V / DC250V | 2.5 | 88.5 | 30.5 | 95 | G1/2 | Caster | 3NC+2NC | General type (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 612.38 | 1 Piece(s) | 18 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | G1/2 | Standard type | 3NC+2NC | Special release key (Resin) / Bottom | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 619.95 | 1 Piece(s) | 5 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | G1/2 | Standard type | 3NC+2NC | Special release key (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 2NC (Slow-action) | Plastic | ||
MYR 607.36 | 1 Piece(s) | 5 Day(s) or more | - | - | UL / CE / GB(CCC) / CSA | - | - | - | - | - | - | - | - | G1/2 | Standard type | 3NC+2NC | General type (Resin) / Front | 24 V DC Solenoid Lock System / Mechanical Release System | 3NC (Slow-action) + 2NC (Slow-action) | Plastic |
Loading...
| Main Body Size | Small | Environment | Standard | Operating Temperature Range(°C) | -10::55 |
|---|---|---|---|---|---|
| Protection Structure | IP67 | Mechanical Life(10,000 times) | 100 | Mechanical Operation Frequency(times/min or Less) | 30 |
| Indicator Light | AC/DC10 - 115V Drive type (Orange LED) | Mounting System | 4-direction mounting supported (front direction at shipment) | AC Rated Voltage | 120/240 |
| DC Rated Voltage | 125/250 | Door Switch Type | Safety Door Switch |
![Small Safety Door Switch / Slide Key Unit [D4NS/D4NS-SK]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221005138013.jpg?$product_recommend_b$)
OMRON
Standard Price : MYR 124.08-
Days to Ship : 2 Day(s) or more

OMRON
Standard Price : MYR 68.00-
Days to Ship : 2 Day(s) or more
![Safety Door Switch [D4BS]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221005137999/221005137999_20210409115437.jpg?$product_recommend_b$)
![Slim Type Safety / Door Switch [D4GS-N]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221005137988/221005137988_20210409115436.jpg?$product_recommend_b$)
OMRON
Standard Price : MYR 35.09-
Days to Ship : 2 Day(s) or more


MISUMI
Standard Price : MYR 310.78-
Days to Ship : 9 Day(s) or more

![Small Safety Limit Switch [D4N]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221005138046_004.jpg?$product_recommend_b$)
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy