(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Roller lever type with thickness of 16 mm. The cable connection is connector connection type with easy replacement of limit switch.
Part Number
Configured Part Number is shown.
D4CC-1050

Note: In the above external dimension diagrams for each model, the dimensional tolerance of the Limit Switch for unspecified parts is ±0.4 mm.
*For information on model numbers other than those listed above, please refer to the digital catalog.
Center roller lever Limit Switch type with operation indicator light

| Protective structure | IP67 | |
|---|---|---|
| Durability *1 | Mechanical | Over 10 million times |
| Limit Switch Electrical | Over 200,000 times (AC125V 1A resistive load) | |
| Allowable Operating Speed | 0.1mm to 0.5m/s (for plunger type) 1mm to 1m/s (for roller lever type) | |
| Allowable operating frequency | Mechanical | 120 times/min |
| Limit Switch Electrical | 30 times/min | |
| Rated Frequency | 50/60Hz | |
| Insulation resistance | 100MΩ or more (at DC500V mega) | |
| Contact resistance (initial value) | 100mΩ or less | |
| Withstand voltage | Between same-polarity terminals | AC1,000V 50/60Hz 1min |
| Between live metal parts and earth | AC1,500V 50/60Hz 1min | |
| Between each terminal and non-current-carrying metal parts | AC1,500V 50/60Hz 1min | |
| vibration | malfunction | 10 to 55Hz, double amplitude 1.5mm *2 |
| Shock Resistant | Durability | Up to 1,000m/ s2 |
| malfunction | Maximum 500m/s2 * 2 | |
| Ambient temperature | -10 to +70℃ (but do not freeze) | |
| Ambient humidity | 35~95% RH | |
| mass | Approx. 120g (for D4CC-1002) | |
Note: The above values are initial values.
*1. The durability values are for ambient Limit Switch of 5 to 35°C and humidity of 40 to 70% RH.
*2. Plastic rod Limit Switch type is excluded.
| Part Number |
|---|
| D4CC-1050 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Detector Shape | Plunger Shape Type | Boot Seal | Roller Lever Shape Type | Rod Shape Type | Acquired Standards | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Contact Type | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Cable Specifications | Detector Element Details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Specification of Terminal | O.D. | Mounting System | Direction of Operation | Roller Type | Contact format | AC Rated Voltage | DC Rated Voltage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 252.47 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | - | - | - | [Spring + Resin Rod] Plastic Rod | UL / GB(CCC) / CSA | 1.47 | - | 15 | - | Single Pole Double Throw | AC100/125V | 1 | 40 | 16 | 57 | - | Model XS2F-A421-□ 90-F (for AC) | Plastic rod type | No | - | - | Connector | φ3.2 | Front mounting | Snap Action | - | 1c | 125 | - |
Loading...
| Main Body Size | Small | Environment | Standard | Operating Temperature Range(°C) | -10::70 |
|---|---|---|---|---|---|
| Protection Structure | IP67 | Mechanical Life(10,000 times) | 1000 | Mechanical Operation Frequency(times/min or Less) | 120 |
![Small Limit Switch [D4C]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559251.jpg?$product_recommend_b$)
![Two-Circuit Limit Switch [WL-N/WL]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221000559396_010.jpg?$product_recommend_b$)
![Small Safety Limit Switch [D4N]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221005138046_004.jpg?$product_recommend_b$)
![Small Limit Switch [HL-5000]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221000559453_001.jpg?$product_recommend_b$)
![Small Enclosed Switch [D4E-□N]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559262.jpg?$product_recommend_b$)
![Compact Sealed Switch [ZC-□55]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221000559419_001.jpg?$product_recommend_b$)
![Compact Enclosed Switch [SHL]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559341.jpg?$product_recommend_b$)
![Small Safety Limit Switch [D4F]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221005138035.jpg?$product_recommend_b$)
![Semi-Compact Sealed Switch [D4MC]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559273.jpg?$product_recommend_b$)
![Multi-Pull Limit Switch [VB]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221000559363/221000559363_20210409115436.jpg?$product_recommend_b$)

![Tactile Switch [D5B]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559295.jpg?$product_recommend_b$)
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy