(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Slim General-purpose Relays (E-TR2ZL-8A-DC24)

Slim General-purpose Relays E-TR2ZL-8A-DC24

Click this image to zoom it.

Move the mouse over the image to zoom

  • Slim General-purpose Relays E-TR2ZL-8A-DC24
  • Slim General-purpose Relays E-TR2ZL-8A-DC24
  • Slim General-purpose Relays E-TR2ZL-8A-DC24
Product Overview
● Slim general-purpose relays are devices that receive input signals and output electrical signals to open or close circuits.
● Available in a wide variety of types, suitable for various control methods and relays inside control panels, with a maximum load of 12 A.
Dimensional Drawing
■ Relay dimension diagram
Sensor Application Example
Sensor Application Example
Note: Pin configurations may vary slightly depending on the model.
 
■ Internal connection diagram (bottom view)
Sensor Application Example
E-TR2Z
Sensor Application Example
E-TR1Z
 

■ Relay Base Dimensions
Sensor Application Example
Note: The appearance may vary slightly depending on the specifications.
Specification Table
ModelLoadOperating time*1Release time*1Contact configurationA1 (pin height)B1Indicator lightSurge protectionWeight (relay)Certification (relay)
RelaySet (relay + relay socket)Rated current*1Rated voltage*1mmmmg
E-TR2ZL-8A-DC24E-TR2ZL-8A-DC24-SET8A277 V AC/30 V DC≤ 20 ms≤ 20 ms2C630.6YesNo20UL CCC CE
E-TR2ZD-8A-DC24E-TR2ZD-8A-DC24-SET8A≤ 20 ms≤ 20 ms2C630.6Yes20
E-TR1ZL-12A-DC24E-TR1ZL-12A-DC24-SET12A≤ 20 ms≤ 20 ms1C531.6No20
E-TR1ZD-12A-DC24E-TR1ZD-12A-DC24-SET12A≤ 20 ms≤ 20 ms1C531.6Yes20

■ Performance parameters
ModelE-TR series
Input
(operating coil)*1
Rated voltageVDC24
Coil resistanceΩ1084
Operating voltageV≥ DC18
Reset voltageV≤ DC3.6
Maximum allowable voltageVDC30
PowermWApprox. 530
Contact materialSilver alloy
Maximum switching frequencyMechanical18,000/h
Rated load1,800/h
Contact resistance*2≤ 100
VibrationMalfunctionVibrate in three directions for 5 minutes, malfunction not exceeding 1 ms (amplitude 1 mm, 10–55 Hz)
Vibration durabilityVibrate in three directions for 2 hours, no structural failure (amplitude 1 mm, 10–55 Hz)
ShockMalfunctionThree shocks applied in three directions, contact malfunction does not exceed 1 ms (maximum acceleration 98 m/s2, duration 11 ms)
Shock resistanceThree shocks applied in three directions, no structural damage (maximum acceleration 98 m/s2, duration 6 ms)
Insulation strengthBetween contacts1000 V AC, 1 min
Between coil and contacts5000 V AC, 1 min
Insulation resistance≥ 100
Service lifeMechanical10,000 times≥ 1,000
Electrical*310,000 times≥ 10
Note:
 *1. Coil temperature is +23°C, resistive load
 *2. Measurement conditions: 6 V DC 1 A voltage drop method
 *3. Test conditions: rated resistive load, frequency 900 cycles/h
Sensor Application Example
(Set product)
■ Set product base specifications and dimensions
ModelRelay socketWeight
ModelABCMounting methodWiring methodFinger protectionCertification
Set
(relay + relay socket)
(Set product)
mmmmmmg
E-TR2ZL-8A-DC24-SETE-TS2Z-10A74.532.15.8DIN railM3 screwYesUL CE50
E-TR2ZD-8A-DC24-SET
E-TR1ZL-12A-DC24-SETE-TS1Z-16A74.532.15.846
E-TR1ZD-12A-DC24-SET
Product Features
● Slim universal relay with space-saving design; product width is 12.7 mm and socket width is 15.8 mm
● All models come standard with an LED operation indicator; built-in surge protection type is also available as an option.
● Optional relay set (relay + relay socket) for complete selection.
● Certified by UL, CE, and CCC.
Precautions
· No installation direction restrictions; please avoid installation methods where the contact movement direction is easily affected by vibration or impact.
· Do not operate while powered.
· Operating environment: -40°C to +85°C, no freezing, no condensation, humidity 45–85%.
· Assembly required for set products; relay socket comes standard with finger protection. Please use Y-type terminals for connection.

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-TR2ZL-8A-DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration Contact rated current (minimum value for AC and DC)
(A)
Type Diode type Mounting method

MYR 17.02

1 Piece(s)Available 6 Day(s) 2c8Relay unitStandard typeSocket type

Loading...

  1. 1
Brand Introduction
Since its establishment in Japan in 1963, MISUMI Corporation has been committed to providing customers with a wide variety of high-quality parts for FA (Factory Automation), mold components, electronic parts, tools, and consumables quickly and accurately. By independently compiling product catalogs and establishing a direct sales marketing system, we have created a low-cost business model. Each year, we develop product plans based on customer feedback and requests, and continuously develop MISUMI brand products with a high level of quality.

Basic Information

Coil rated voltage (DC)(V) 24

Please check the type/dimensions/specifications of the part E-TR2ZL-8A-DC24 in the Slim General-purpose Relays series.

Frequently asked question (FAQ)

Question: What are the external reasons why the relay does not operate after being energized?
Answer: (1) Applying excessive voltage to the relay coil can cause the coil to break.
(2) If the voltage applied to the relay coil is insufficient, the relay will not operate.
(1) The voltage applied to the coil does not reach the minimum operating voltage.
(2) The voltage in the circuit may drop below the minimum operating voltage due to the operation of large machines or the use of long-distance wiring.
(3) If the ambient temperature is too high, the resistance of the relay coil increases, causing the required operating voltage to rise. As a result, the originally applied rated voltage is no longer sufficient to drive the relay.

Products like this...

Part Number
E-TR1ZD-12A-DC24-SET
E-TR1ZL-12A-DC24
E-TR1ZL-12A-DC24-SET
E-TR2ZD-8A-DC24
E-TR2ZD-8A-DC24-SET
E-TR2ZL-8A-DC24-SET
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration Contact rated current (minimum value for AC and DC)
(A)
Type Diode type Mounting method

MYR 20.02

1 Piece(s)Available 6 Day(s) 1c12Set (relay + relay socket)Built-in diode surge protectionDIN rail

MYR 12.15

1 Piece(s)Available 6 Day(s) 1c12Relay unitStandard typeSocket type

MYR 19.70

1 Piece(s)Available 6 Day(s) 1c12Set (relay + relay socket)Standard typeDIN rail

MYR 17.34

1 Piece(s)Available 6 Day(s) 2c8Relay unitBuilt-in diode surge protectionSocket type

MYR 21.76

1 Piece(s)Available 6 Day(s) 2c8Set (relay + relay socket)Built-in diode surge protectionDIN rail

MYR 21.44

1 Piece(s)Available 6 Day(s) 2c8Set (relay + relay socket)Standard typeDIN rail

Additional Products in this Category