Part Number
Configured Part Number is shown.
E-GR1000-TRVV-0.2-12-100


| Shape | Section Area (mm²) | AWG | Core Number Range |
| CLASS-B E-GR1000-TRVV Non-Shielded | 0.2 | 24 | 2-20 |
| 0.3 | 23 | ||
| 0.5 | 20 | ||
| 0.75 | 18 | 2-12 | |
| CLASS-B E-GR1000-TRVVPS Twisted Pair Shielded | 0.12 | 26 | 2P-5P |
| 0.2 | 24 | 1P-20P | |
| 0.3 | 23 | ||
| 0.5 | 20 | 1P-6P |

| Core Wire | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Insulation Color | Blue | Orange | Green | Brown | Gray | Red | Black | Yellow | Pink | Purple |
| Core Wire | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 |
| Insulation Color | White | Blue Red | Orange White | Green White | Brown White | Gray White | Red White | Black White | Yellow Black | Pink Black |


| Type | Cross Section (mm²) | Number of Wire Cores | AWG | Cable O.D. (mm) | Reference Mass (kg/km) | Electrical Properties | Conductor (Non-Electroplating) | Insulation (PVC) | Wire Core O.D. approx. (mm) | Sheath (PVC) | ||||
| Allowable Current MAX A(30℃) | Conductor Resistance Ω/km (20℃) | Insulation Properties MΩ/km (20℃) | Max Voltage V/minute | Core Wire Structure pcs/mm | O.D. approx. (mm) | Thickness (mm) | Thickness (mm) | |||||||
| 10 Million Times Machinery Robot Control Cables E-GR1000-TRVV | 0.2 | 2 | 24 | 4.3 | 24 | 5.8 | 87.6 or Less | 10 or More | 2000 | 41/0.08 | 0.59 | 0.3 | 1.19 | 0.9 |
| 3 | 4.5 | 29 | 4.9 | 0.9 | ||||||||||
| 4 | 4.8 | 33 | 4.4 | 0.9 | ||||||||||
| 6 | 5.5 | 45 | 3.8 | 0.9 | ||||||||||
| 8 | 6.2 | 57 | 3.5 | 0.9 | ||||||||||
| 10 | 6.7 | 66 | 3.3 | 0.9 | ||||||||||
| 12 | 6.8 | 74 | 3.0 | 0.9 | ||||||||||
| 20 | 8.2 | 111 | 2.5 | 0.9 | ||||||||||
| 0.3 | 2 | 23 | 4.5 | 28 | 7.2 | 63.2 or Less | 10 or More | 2000 | 60/0.08 | 0.72 | 0.3 | 1.32 | 0.9 | |
| 3 | 4.8 | 34 | 6.1 | 0.9 | ||||||||||
| 4 | 5.1 | 40 | 5.4 | 0.9 | ||||||||||
| 5 | 5.5 | 48 | 4.9 | 0.9 | ||||||||||
| 6 | 5.9 | 54 | 4.7 | 0.9 | ||||||||||
| 8 | 6.7 | 70 | 4.4 | 0.9 | ||||||||||
| 10 | 7.2 | 81 | 4.0 | 0.9 | ||||||||||
| 12 | 7.4 | 91 | 3.8 | 0.9 | ||||||||||
| 16 | 8.1 | 113 | 3.4 | 0.9 | ||||||||||
| 20 | 9.1 | 143 | 3.2 | 1 | ||||||||||
| 0.5 | 2 | 20 | 5.0 | 39 | 10.2 | 34.4 or Less | 10 or More | 2000 | 108/0.08 | 0.96 | 0.3 | 1.56 | 0.9 | |
| 3 | 5.3 | 45 | 8.6 | 0.9 | ||||||||||
| 4 | 5.7 | 55 | 7.7 | 0.9 | ||||||||||
| 5 | 6.1 | 66 | 7.4 | 0.9 | ||||||||||
| 6 | 6.6 | 77 | 6.7 | 0.9 | ||||||||||
| 8 | 7.5 | 98 | 6.2 | 0.9 | ||||||||||
| 10 | 8.3 | 119 | 5.8 | 1 | ||||||||||
| 12 | 8.6 | 134 | 5.4 | 1 | ||||||||||
| 16 | 9.4 | 169 | 4.8 | 1 | ||||||||||
| 20 | 10.6 | 212 | 4.5 | 1.1 | ||||||||||
| 0.75 | 2 | 18 | 6.0 | 52 | 13.5 | 21.8 or Less | 10 or More | 2000 | 7/23/0.08 | 1.35 | 0.35 | 2.05 | 0.9 | |
| 3 | 6.3 | 65 | 11.3 | 0.9 | ||||||||||
| 4 | 6.9 | 79 | 10.2 | 0.9 | ||||||||||
| 6 | 8.3 | 115 | 9.0 | 1 | ||||||||||
| 8 | 9.5 | 150 | 8.3 | 1 | ||||||||||
| 9 | 10.1 | 163 | 5.7 | 1.1 | ||||||||||
| 12 | 10.8 | 203 | 7.2 | 1.1 | ||||||||||
| Item | Specifications | Conditions | Note | ||
Insulation Properties | Tensile Strength | (Lbf/in2) | ![]() | - | ![]() |
| (Mpa) | |||||
| Elongation | (%) | ||||
| Tensile Strength after Aging | (%) | ||||
| Elongation after Aging | (%) | ||||
| Aging Conditions | 168 Hours at 80℃ | ||||
| Tensile Strength | (Lbf/in2) | 1500 or More | - | Test method: ·Refer to UL758 | |
| (Mpa) | 10.3 or More | - | |||
| Elongation | (%) | 100 or More | - | ||
| Tensile Strength after Aging | (%) | 70 or More | - | ||
| Elongation after Aging | (%) | 65 or More | - | ||
| Aging Conditions | 168 Hours at 113℃ | ||||
Coating Properties | Tensile Strength | (Lbf/in2) | ![]() | - | ![]() |
| (Mpa) | |||||
| Elongation | (%) | ||||
| Tensile Strength after Aging | (%) | ||||
| Elongation after Aging | (%) | ||||
| Aging Conditions | 168 Hours at 80℃ | ||||
| Tensile Strength | (Lbf/in2) | 1500 or More | - | Test method: ·Refer to UL758 ·Flame Retardance Test VW-1 | |
| (Mpa) | 10.3 or More | - | |||
| Elongation | (%) | 100 or More | - | ||
| Tensile Strength after Aging | (%) | 70 or More | - | ||
| Elongation after Aging | (%) | 65 or More | - | ||
| Aging Conditions | 168 Hours at 113℃ | ||||

| Part Number |
|---|
| E-GR1000-TRVV-0.2-12-100 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Conductor Cross Section (mm2) | AWG size (AWG) | Number Of Cores (Core) |
|---|---|---|---|---|---|---|---|
MYR 936.30 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 12 |
Loading...

| Type | Cross Section (mm²) | Number of Wire Cores (Twisted Pair Structure) | AWG | Cable O.D. (mm) | Reference Mass (kg/km) | Electrical Properties | Conductor (Non-Electroplating) | Insulation (PVC) | Wire Core O.D. approx. (mm) | Sheath (PVC) | ||||
| Allowable Current MAX A(30℃) | Conductor Resistance Ω/km (20℃) | Insulation Properties MΩ/km (20℃) | Max Voltage V/minute | Core Wire Structure pcs/mm | O.D. approx. (mm) | Thickness (mm) | Thickness (mm) | |||||||
| 10 Million Times Machinery Robot Control Cables E-GR1000-TRVV | 0.2 | 2 | 24 | 4.3 | 24 | 5.8 | 87.6 or Less | 10 or More | 2000 | 41/0.08 | 0.59 | 0.3 | 1.19 | 0.9 |
| 3 | 4.5 | 29 | 4.9 | 0.9 | ||||||||||
| 4 | 4.8 | 33 | 4.4 | 0.9 | ||||||||||
| 6 | 5.5 | 45 | 3.8 | 0.9 | ||||||||||
| 8 | 6.2 | 57 | 3.5 | 0.9 | ||||||||||
| 10 | 6.7 | 66 | 3.3 | 0.9 | ||||||||||
| 12 | 6.8 | 74 | 3.0 | 0.9 | ||||||||||
| 20 | 8.2 | 111 | 2.5 | 0.9 | ||||||||||
| 0.3 | 2 | 23 | 4.5 | 28 | 7.2 | 63.2 or Less | 10 or More | 2000 | 60/0.08 | 0.72 | 0.3 | 1.32 | 0.9 | |
| 3 | 4.8 | 34 | 6.1 | 0.9 | ||||||||||
| 4 | 5.1 | 40 | 5.4 | 0.9 | ||||||||||
| 5 | 5.5 | 48 | 4.9 | 0.9 | ||||||||||
| 6 | 5.9 | 54 | 4.7 | 0.9 | ||||||||||
| 8 | 6.7 | 70 | 4.4 | 0.9 | ||||||||||
| 10 | 7.2 | 81 | 4.0 | 0.9 | ||||||||||
| 12 | 7.4 | 91 | 3.8 | 0.9 | ||||||||||
| 16 | 8.1 | 113 | 3.4 | 0.9 | ||||||||||
| 20 | 9.1 | 143 | 3.2 | 1 | ||||||||||
| 0.5 | 2 | 20 | 5.0 | 39 | 10.2 | 34.4 or Less | 10 or More | 2000 | 108/0.08 | 0.96 | 0.3 | 1.56 | 0.9 | |
| 3 | 5.3 | 45 | 8.6 | 0.9 | ||||||||||
| 4 | 5.7 | 55 | 7.7 | 0.9 | ||||||||||
| 5 | 6.1 | 66 | 7.4 | 0.9 | ||||||||||
| 6 | 6.6 | 77 | 6.7 | 0.9 | ||||||||||
| 8 | 7.5 | 98 | 6.2 | 0.9 | ||||||||||
| 10 | 8.3 | 119 | 5.8 | 1 | ||||||||||
| 12 | 8.6 | 134 | 5.4 | 1 | ||||||||||
| 16 | 9.4 | 169 | 4.8 | 1 | ||||||||||
| 20 | 10.6 | 212 | 4.5 | 1.1 | ||||||||||
| 0.75 | 2 | 18 | 6.0 | 52 | 13.5 | 21.8 or Less | 10 or More | 2000 | 7/23/0.08 | 1.35 | 0.35 | 2.05 | 0.9 | |
| 3 | 6.3 | 65 | 11.3 | 0.9 | ||||||||||
| 4 | 6.9 | 79 | 10.2 | 0.9 | ||||||||||
| 6 | 8.3 | 115 | 9.0 | 1 | ||||||||||
| 8 | 9.5 | 150 | 8.3 | 1 | ||||||||||
| 9 | 10.1 | 163 | 5.7 | 1.1 | ||||||||||
| 12 | 10.8 | 203 | 7.2 | 1.1 | ||||||||||
| Shield | None | Representative Standard | CE | Electroplating | Not provided |
|---|---|---|---|---|---|
| Sheath (Outer Skin) Color Detail | Black | Length(m) | 100 |
Please check the type/dimensions/specifications of the part E-GR1000-TRVV-0.2-12-100 in the TRVV Non-Shielded Robot Cables 300V, High Flexibility series.
| Part Number |
|---|
| E-GR1000-TRVV-0.2-10-100 |
| E-GR1000-TRVV-0.2-2-100 |
| E-GR1000-TRVV-0.2-20-100 |
| E-GR1000-TRVV-0.2-3-100 |
| E-GR1000-TRVV-0.2-4-100 |
| E-GR1000-TRVV-0.2-6-100 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Conductor Cross Section (mm2) | AWG size (AWG) | Number Of Cores (Core) |
|---|---|---|---|---|---|---|---|
MYR 824.18 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 10 | |
MYR 253.96 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 2 | |
MYR 1,433.98 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 20 | |
MYR 306.46 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 3 | |
MYR 390.60 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 4 | |
MYR 522.98 | 1 Piece(s) | Available | 6 Day(s) | 0.2 | 24 | 6 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy