This is an emergency stop switch with various standards certified. Mounting hole diameter: ø16/ø22/ø30 Non-illuminated


Part Number
Configured Part Number is shown.
EBS3411-DB

| Optional Items at Extra Charge * Note 1 | Symbol |
| Nameplate (EMERGENCY STOP) | DA |
| Nameplate (EMERGENCY STOP) | DB |
| Guard * Note 2 | G |
| Model Number | Mounting Hole Ø | Operation Part | Configuration | Structure | Short Body | Protective Structure | Acquired Standards | Terminal | Specification Group | ||||||
| UL | cUL | CSA | TUV | CE | CCC | DEMKO | |||||||||
| EBS1201 | 16 | Ø 29 | 1b | Separation | ● | Panel Front Surface IP65 | ● | ● | - | ● | ● | ● | - | Solder | A |
| EBS1202 | 2b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS1211 | 1a1b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS1204 | 4b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS1401 | Ø 40 | 1b | ● | ● | ● | - | ● | ● | ● | - | |||||
| EBS1402 | 2b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS1411 | 1a1b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS1401EMO | 1b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBB2201 | 22 | Ø 29 | 1b | - | ● | - | ● | ● | ● | ● | - | M3.5 Screw Terminal | B | ||
| EBB2202 | 2b | - | ● | - | ● | ● | ● | ● | - | ||||||
| EBB2211 | 1a1b | - | ● | - | ● | ● | ● | ● | - | ||||||
| EB2402 | Ø 40 | 2b | Integrated | - | ● | ● | - | - | ● | ● | ● | C | |||
| EB2411 | 1a1b | - | ● | ● | - | - | ● | ● | ● | ||||||
| EBB2401 | 1b | Separation | - | ● | - | ● | ● | ● | ● | - | B | ||||
| EBB2402 | 2b | - | ● | - | ● | ● | ● | ● | - | ||||||
| EBB2411 | 1a1b | - | ● | - | ● | ● | ● | ● | - | ||||||
| EBS2401 | 1b | ● | ● | ● | - | ● | ● | ● | - | D | |||||
| EBS2402 | 2b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS2411 | 1a1b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBS2404 | 4b | ● | ● | ● | - | ● | ● | ● | - | ||||||
| EBB2411EMO | 1a1b | - | ● | - | ● | ● | ● | ● | - | B | |||||
| EB3402 | 30 | 2b | Integrated | - | ● | ● | - | - | ● | ● | ● | C | |||
| EB3411 | 1a1b | - | ● | ● | - | - | ● | ● | ● | ||||||
| EBS3401 | 1b | Separation | ● | ● | ● | - | ● | ● | - | - | D | ||||
| EBS3402 | 2b | ● | ● | ● | - | ● | ● | - | - | ||||||
| EBS3411 | 1a1b | ● | ● | ● | - | ● | ● | - | - | ||||||
| EBS3404 | 4b | ● | ● | ● | - | ● | ● | - | - | ||||||
| Specification Group | Switch Circuit Ratings | Working Temperature Range | Insulation Resistance 500 VDC Megger | Overvoltage Category | Durability | Mass g (Approx.) | ||||||||||
| Rated Insulation Voltage (Ui) | Rated Conducting Current (lth) | Rated Working Voltage (Ue) | Rated Working Current | |||||||||||||
| Main Contact | Monitor Contact | |||||||||||||||
| AC 50 / 60 Hz | DC | AC 50 / 60 Hz | DC | |||||||||||||
| Resistive Load (AC-12) | Inductive Load (AC-15) | Resistive Load (DC-12) | Inductive Load (DC-13) | Resistive Load (AC-12) | Inductive Load (AC-15) | Resistive Load (DC-12) | Inductive Load (DC-13) | |||||||||
| A | 300V | 5A | 30V | - | - | 2A | 1A | - | - | 2A | 1A | -25 ~ +60°C | 100 MΩ or more | II | Mechanical 250,000 Times or more Electrical 100,000 Times or more | Operation Part Ø29 - 23 g Ø40 - 28 g |
| 125V | 3A | 1.5A | 0.4A | 0.22A | 1.2A | 0.6A | 0.4A | 0.22A | ||||||||
| 250V | 3A | 1.5A | 0.2A | 0.1A | 0.6A | 0.3A | 0.2A | 0.1A | ||||||||
| B | 600V | 10A | 24V | 10A | 10A | 8A | 4A | - | - | - | - | - | Mechanical / Electrical 500,000 Times or more | Operation Part Ø29 - 76 g Ø40 - 99 g | ||
| 110V | 10A | 5A | 2.2A | 1.1A | - | - | - | - | ||||||||
| 220V | 6A | 3A | 1.1A | 0.6A | - | - | - | - | ||||||||
| C | 250V | 10A | 24V | 6A | 6A | 6A | 1.5A | - | - | - | - | - | Mechanical 250,000 Times or more Electrical 100,000 Times or more | Mounting Hole Ø22 - 49 g Ø30 - 58 g | ||
| 110V | 3A | 3A | 2A | 0.3A | - | - | - | - | ||||||||
| 220V | 3A | 3A | 1A | 0.15A | - | - | - | - | ||||||||
| D | 5A | 30V | - | - | 2A | 1A | - | - | 2A | 1A | II | Mounting Hole Ø22 - 72 g Ø30 - 83 g | ||||
| 125V | 5A | 3A | 0.4A | 0.22A | 1.2A | 0.6A | 0.4A | 0.22A | ||||||||
| 250V | 3A | 1.5A | 0.2A | 0.1A | 0.6A | 0.3A | 0.2A | 0.1A | ||||||||



| Part Number |
|---|
| EBS3411-DB |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Shape | Card included | Name Plate | Terminal shape | Mounting Hole | Contact Configuration | Push button operation | Representative Standard | Dimension vertical (mm) | Dimension width (mm) | Dimension depth (mm) | When Current capacity is AC 110 V (A) | Ampacity @ 24 VDC (A) | Ampacity @ 125 VAC (A) | Ampacity @ 30 VDC (A) | Operating unit dimensions (mushroom) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 244.21 | 1 Piece(s) | Available | 4 Day(s) or more | Circular | None | Present | Screw terminal | Φ 30 | 1a / 1b | - | CE / UL / CUL / TUV | 40 | 40 | 80.7 | - | - | - | - | φ40 |
Loading...
Technical Data
Switch Outline Drawing Emergency Stop
Switch Terminal Arrangement Diagram

Panel Hole Processing Diagram

Manufacturer Part No. / International Standard No. Correspondence Table
| Type | Non-illumination type emergency stop | Protection function (environmentally resistant) | Panel front surface IP65 |
|---|
Please check the type/dimensions/specifications of the part EBS3411-DB in the Non-illuminated Emergency Stop Switch Mounting Hole φ16, φ22, φ30 series.
| Part Number |
|---|
| EBB2201 |
| EBB2201-G |
| EBB2202 |
| EBB2202-G |
| EBB2211 |
| EBB2211-G |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Shape | Card included | Name Plate | Terminal shape | Mounting Hole | Contact Configuration | Push button operation | Representative Standard | Dimension vertical (mm) | Dimension width (mm) | Dimension depth (mm) | When Current capacity is AC 110 V (A) | Ampacity @ 24 VDC (A) | Ampacity @ 125 VAC (A) | Ampacity @ 30 VDC (A) | Operating unit dimensions (mushroom) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 126.83 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | None | None | Screw terminal | Φ 22 | 1b | Push to lock/turn to reset | UL / TUV / CCC | 41.4 | 29.4 | 81.4 | 10 | 8 | - | - | φ29 | |
MYR 211.26 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | Present | None | Screw terminal | Φ 22 | 1b | Push to lock/turn to reset | - | - | - | - | - | - | - | - | - | |
MYR 151.65 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | None | None | Screw terminal | Φ 22 | 2b | Push to lock/turn to reset | CE / UL / TUV / CCC | 41.4 | 29.4 | 81.4 | 10 | 8 | - | - | φ29 | |
MYR 236.08 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | Present | None | Screw terminal | Φ 22 | 2b | Push to lock/turn to reset | - | - | - | - | - | - | - | - | - | |
MYR 151.65 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | None | None | Screw terminal | Φ 22 | 1a / 1b | Push to lock/turn to reset | CE / UL / TUV / CCC | 41.4 | 29.4 | 81.4 | 10 | 8 | - | - | φ29 | |
MYR 236.08 | 1 Piece(s) | Available | 4 Day(s) or more | Mushroom shape | Present | None | Screw terminal | Φ 22 | 1a / 1b | Push to lock/turn to reset | - | - | - | - | - | - | - | - | - |

MISUMI
Standard Price : MYR 202.83-
Days to Ship : 2 Day(s) or more

IDEC
Standard Price : MYR 106.18-
Days to Ship : 5 Day(s) or more
OMRON
Standard Price : MYR 82.18-
Days to Ship : 1 Day(s) or more

OMRON
Standard Price : MYR 96.00-
Days to Ship : 1 Day(s) or more

MISUMI
Standard Price : MYR 85.52-
Days to Ship : 2 Day(s) or more

IDEC
Standard Price : MYR 139.76-
Days to Ship : 4 Day(s) or more

MISUMI
Standard Price : MYR 48.66-
Days to Ship : 4 Day(s) or more

IDEC
Standard Price : MYR 181.80-
Days to Ship : 5 Day(s) or more

MISUMI
Standard Price : MYR 111.62-
Days to Ship : 4 Day(s) or more

MISUMI
Standard Price : MYR 69.38-
Days to Ship : 2 Day(s) or more

IDEC
Standard Price : MYR 156.53-
Days to Ship : 5 Day(s) or more

MISUMI
Standard Price : MYR 50.55-
Days to Ship : 2 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy