Part Number
Configured Part Number is shown.
| (Economy) SL-PHE SH-PHE SHD-PHE ![]() ·2-side Sawing, 2-side Precision Cutting ·Perpendicularity of datum plane is guaranteed. | (Standard Grade) SL-PHX SH-PHX SHD-PHX ![]() ·4-Surface Precision Cutting ·Perpendicularity of datum plane is NOT guaranteed. ·A, B Dimension Tolerance Accuracy | (Precision Grade) SL-PHT SH-PHT SHD-PHT ![]() ·4-Surface Precision Cutting ·Perpendicularity of datum plane is guaranteed. ·A, B Dimension Tolerance Accuracy |
| Type | [M] Material | Cleaning Method | |||||
| Economy | Standard Grade | Precision Grade | Cleaning Method | Cleaning Environment | Packaging Type | Packing Environment | |
| SL-PHE | SL-PHX | SL-PHT | A5052P−H112 | Degreasing | General environment | Anti-rust packing | General environment |
| SH-PHE | SH-PHX | SH-PHT | Precision cleaning | Class 1,000 | Degassing double packing | Class 10 | |
| SHD-PHE | SHD-PHX | SHD-PHT | Electrolytic polishing + precision cleaning | ||||
specification table.| Part Number | — | A | — | B | — | T |
| SL-PHX | — | 630.5 | — | 121 | — | 10 |
| Part Number | A | B | T | |
| A ≥ B | Selection | |||
| Economy | SL-PHE SH-PHE SHD-PHE | 500 to 800 | 20 to 800 | 4·5·6·8·10·12·15·20·25·30·35·40·45·50 |
| (1 mm Increments) | (1 mm Increments) | |||
| Standard Grade | SL-PHX SH-PHX SHD-PHX | 500 to 800 | 20 to 800 | |
| Precision Grade | SL-PHT SH-PHT SHD-PHT | (0.1 mm Increments) | (0.1 mm Increments) | |
| Part Number | A, B dimension | Selectable |
| SL-PHE SH-PHE SHD-PHE | 20 to 800 | 0 to +1.0 |
| SL-PHX SH-PHX SHD-PHX | 20 to 199.9 | ±0.1 |
| 200 to 399.9 | ±0.15 | |
| 400 to 799.9 | ±0.2 | |
| SL-PHT SH-PHT SHD-PHT | 20 to 199.9 | ±0.05 |
| 200 to 399.9 | ±0.06 | |
| 400 to 799.9 | ±0.08 |
| T | 4·5·6 | 8·10·12 | 15 | 20 | 25·30·35·40·45·50 |
| Tolerance | ±0.04 | ±0.05 | ±0.08 | ±0.10 | ±0.15 |
| Item | SL-PHX·SH-PHX·SHD-PHX | SL-PHE·SH-PHE·SHD-PHE SL-PHT·SH-PHT·SHD-PHT |
| Flatness | 0.4 mm | |
| (per 1,000 mm) | ||
| Perpendicularity of Datum Plane | Reference Value (0.02) | 0.015 |
| (per 100 mm) | ||
| Part Number | — | A | — | B | — | T | — | (CCA, etc.) |
| SL-PHX | — | 630.5 | — | 250.5 | — | 10 | — | CCA30-CCC50 |
| Alterations | Corner Cut |
[ ! ] Applicable Size ![]() | |
| Code | CCA·CCB·CCC·CCD |
| Spec. | Any corner can be cut. 1 ≤ Corner Cut ≤ 100 1 mm Increments C ≤ A2 , B2 Ordering Code Example: When the corners of A and D are cut by C5 →CCA5-CCD5 |
Cleaning Process
* Stainless steel products may be used with alkaline hot pure water. There is no change in cleanliness.
* If the surface treatment is low-temperature black chrome plating, IPA cleaning will be applied.
Working Environment: General environment | ||||||
|---|---|---|---|---|---|---|
![]() Hydrocarbon cleaning Ro water cleaning Neutral Detergent Cleaning | ![]() | ![]() High-pressure jet washing (Ro water) followed by pure water cleaning | ![]() | ![]() Oil-free Compressor Used | ![]() | ![]() Anti-rust single packing |
Working Environment: Class 1,000 | Working Environment: Class 10 | |||||||
|---|---|---|---|---|---|---|---|---|
![]() Hydrocarbon cleaning Ro water cleaning Neutral Detergent Cleaning | ![]() | ![]() High-pressure jet washing (Ro water) followed by pure water (10 MΩ·cm) cleaning | ![]() | ![]() Use pure water (13 MΩ·cm) | ![]() | ![]() Use nitrogen blow | ![]() | ![]() Conducted on a clean bench in a Class 10 clean environment |
Working Environment: Class 1,000 | Working Environment: Class 10 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
![]() Hydrocarbon cleaning Ro water cleaning Neutral Detergent Cleaning | ![]() | ![]() Electrolytic polishing in an electrolytic polishing tank according to the material | ![]() | ![]() High-pressure jet washing (Ro water) followed by pure water (10 MΩ·cm) cleaning | ![]() | ![]() Use warm pure water (13 MΩ·cm) | ![]() | ![]() Use nitrogen blow | ![]() | ![]() Conducted on a clean bench in a Class 10 clean environment |
Packaging Example| For degreasing: (Part Number: SL-□□) ![]() Depending on some products and dimensions, packaging type may vary. | For precision cleaning or electrolytic polishing + precision cleaning: (Part Number: SH-□□/SHD-□□) ![]() [ ! ] Both the first and second layer packaging are degassed. |
Cleaning Effectiveness / Recommended Environment for UseCleaning Method | Product Part Number | Packaging Type | Effects Compared to Uncleaned Product | Environment (Standard) | Use Case and Process |
|---|---|---|---|---|---|
| Degreasing | SL-□□ | Anti-rust packing | Oil removal | General environment | Regular assembly process |
| Post battery assembly process | |||||
| Precision cleaning | SH-□□ | Degassing double packing | Oil removal Dust removal | Clean environment (Class 10 to 1,000) | Battery assembly process |
| LCD-related post assembly process | |||||
| In-vehicle camera assembly process | |||||
| Electrolytic polishing + precision cleaning | SHD-□□ | Degassing double packing | Oil removal Dust removal Outgas reduction | Vacuum environment Clean environment (Class 10 to 1,000) | Pre-semiconductor process |
| Liquid crystal deposition process | |||||
| Pre-OLED process |
CAD Data download and 3D preview are not available because the part number has not yet been determined.
| Part Number |
|---|
| SH-PHE-[500-800/1]-[20-800/1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SH-PHT-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SH-PHX-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SHD-PHE-[500-800/1]-[20-800/1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SHD-PHT-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SHD-PHX-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SL-PHE-[500-800/1]-[20-800/1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SL-PHT-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| SL-PHX-[500-800/0.1]-[20-800/0.1]-[4,5,6,8,10,12,15,20,25,30,35,40,45,50] |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Thickness T (mm) | Length A (mm) | Width B (mm) | Cleaning Method | W/ or W/o Guaranteed Perpendicularity |
|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Precision cleaning | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Precision cleaning | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Precision cleaning | Perpendicularity of datum plane is NOT guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Electrolytic polishing + precision cleaning | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Electrolytic polishing + precision cleaning | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Electrolytic polishing + precision cleaning | Perpendicularity of datum plane is NOT guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Degreasing | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Degreasing | Perpendicularity of datum plane is guaranteed. | ||
- | 1 Piece(s) | 5 Day(s) or more | 4 ~ 50 | 500 ~ 800 | 20 ~ 800 | Degreasing | Perpendicularity of datum plane is NOT guaranteed. |
Loading...
| Finish Method | Precision Cutting | Material | SUS316 | Surface Roughness | Ra 1.6 |
|---|---|---|---|---|---|
| Surface Treatment | N/A |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy