XZ-Axis Manual Stages, Linear Ball Guide (E-XZSG80)

XZ-Axis Manual Stages, Linear Ball Guide E-XZSG80

Click this image to zoom it.

Move the mouse over the image to zoom

  • XZ-Axis Manual Stages, Linear Ball Guide
  • XZ-Axis Manual Stages, Linear Ball Guide
  • XZ-Axis Manual Stages, Linear Ball Guide
  • Volume Discount

XZ-Axis Manual Stages are an economy item, The price is cheaper than the MISUMI standard product.They offer a wide variety of sizes to choose from.
[Feature]
● Table Dimensions (mm.) : 40X40, 60X60 and 80X80
● Movement (mm) :
X-Axis for 40X40 and 60X60 ±6.5 and ±12.5 for 80X80
Z-Axis for 40X40 and 60X60 ±6.5 and ±12.5 for 80X80
● Material : D2 Tool Steel
● Surface Treatment : Chemically Nickel Plating
[Application]
XZ-Axis Manual Stages are commonly used in various applications in factory automation systems

There have been changes to the manual stage drawings in August 2024. Please download the latest drawings and confirm before placing your order!
Product Overview
The MISUMI E-XZSG series linear ball guide type stage is an economical stage. It can be used as a simple position adjustment stage. The main body is made of stainless steel, providing a certain degree of rust resistance. The guide mechanism uses a linear ball guide, which provides the necessary level of accuracy. Due to localized production in China and improved manufacturing processes, the price has been significantly reduced.
Dimensional Drawing

Dimensional Drawing
Material Table
TypeMaterialSurface treatment
BodySUS440CElectroless nickel plating
Z bracketAluminum alloyNatural anodized
 
Alterations
■ Alterations
AlterationsChange the position of the micrometer knob
Spec.Center
MISUMI Economy Manual Stage with Additional Machining, Micrometer Knob Center Type
Side facing up
MISUMI Economy Manual Stage with Additional Machining, Micrometer Knob Side Left-Right Reverse Type
Side facing down
MISUMI Economy Manual Stage with Additional Machining, Micrometer Knob Side Up-Down Reverse Type
Reverse
MISUMI Economy Manual Stage with Additional Machining, Micrometer Knob Left-Right Up-Down Reverse Type
CodeACCUR
Specification Table
TypeStage surface
(mm)
Travel distance
(mm)
Load capacity
(N)
Straightness
(µm)
Minimum reading
(µm)
Weight
(kg)
TypeNo.
E-XZSG4040 × 40±6.549Within 10100.55
5050 × 500.76
6060 × 600.98
7070 × 701.4
8080 × 80±12.52.1

■ Travel distance
  The catalog drawing dimensions are based on a stroke of 0 mm. Using this as a reference, the distance moved in the left and right directions is the travel distance.

■ Load capacity
  Refers to the force that the slide table can withstand when the workpiece's center of gravity is located at the center of the slide table, measured in N. If used beyond the load capacity, the slide table may not operate smoothly or may become stuck. When installing the linear motion slide table vertically or upside down, the accuracy may be less than the values indicated in the product catalog. Please take note.

■ Straightness
  The maximum deviation of the slide table from the ideal movement axis (the straight line connecting the start and end points, shown as the red line in the diagram below; the black line represents the actual movement path) during full-stroke movement. Measurement method: Place a dial indicator on the slide table with the pointer touching the reference block. Move the slide table through its full stroke and measure the maximum displacement, which is the straightness.

MISUMI manual stage straightness definitionMISUMI manual stage straightness measurement method
Product Features
Feature 1: Shortened production lead time, with delivery in as fast as 5 days.
Feature 2: Achieves a low price by simplifying the structure and improving the manufacturing process.
Feature 3: Supports various additional machining options to meet installation requirements in different situations.
Feature 4: Improved clamping mechanism provides greater holding force for the slide table compared to the standard clamping mechanism.

Usage Method
■ Installation method for X-axis slide table
  When installing the slide table onto the base, the installation is generally performed by moving the slide table surface. Please refer to the diagram below.
Standard installation method for MISUMI manual X-axis stage
The above diagram is for installation example demonstration only. For detailed shapes and specifications of the slide table, please refer to the respective product catalog or 3D data.

■ Installation orientation
DiagramMISUMI X-axis stage horizontal installation diagram MISUMI X-axis stage inverted installation diagram  MISUMI X-axis stage side-mounted horizontal installation diagram MISUMI X-axis stage side-mounted vertical installation diagram
Installation orientationHorizontalInvertedSide-mounted horizontalSide-mounted vertical
Load resistance characteristics
Horizontal, inverted, side horizontal, or side vertical installation can be selected. For other installation methods, please pay special attention.
Depending on the installation orientation, load capacity and accuracy may vary significantly.
○: Same load capacity as horizontal installation.
△: Approximately one-third of the horizontal load capacity is the general standard. If the product catalog lists the vertical load capacity, please give priority to the catalog.

■Vertical Use of X-Axis Stage
  When using the X-axis stage vertically, please pay attention to the feed direction and avoid aligning it with the direction of gravity.
  When using a micrometer knob type stage, please note that the stage is reset by a tension spring. If the applied force exceeds the spring load, the stage platform may drop. In such cases, additional processing can be selected as a solution.
Incorrect usageCorrect usage
(Generally) If the applied force exceeds the tension load of the spring, the stage platform may fall due to insufficient load capacity.After selecting the additional machining to change the micrometer knob position, the stage surface will not drop even when used vertically.
Explanation of incorrect usage examples when MISUMI X-axis stage is used verticallyExplanation of correct usage examples when MISUMI X-axis stage is used vertically
Please avoid applying loads in the vertical direction that exceed the load capacity.
Precautions
■ Operating temperature and environment
  Recommended operating environment: 10–50°C, 20–70% RH (no condensation)
  Accuracy-guaranteed environment: 22±5°C, 20–70% RH (no condensation)

■ Guiding mechanism
  This stage uses a linear guide rail as the guiding mechanism.

■ Clamping mechanism
(1) The clamping mechanism of the stage is fixed by the friction force generated by tightening the screws. Therefore, if an external force exceeding the friction force of the clamping mechanism is applied, the stage will move. Please take appropriate measures during use to prevent the stage surface from moving. If additional clamping reinforcement is required, you can choose either disc clamping or opposed clamping.
(2) Holding force refers to the amount of force that keeps the stage surface from moving when clamped. Since the maximum holding force varies with changes in tightening torque, please ensure a sufficiently large safety factor in your design.

■ Feed Mechanism
A stage equipped with a micrometer knob, as shown in the figure below, is generally referred to as the standard type. The installation space, installation orientation, and operation method can be freely selected. However, due to the structure of the product, there are some models where the installation position of the micrometer knob cannot be changed. For details, please refer to the [Additional Machining] section at the bottom of each product page.
Diagram of micrometer knob position for MISUMI standard manual X-axis stage

■ Flatness of the mounting surface
  The upper and lower slide table surfaces may become deformed due to differences in the flatness of the mounting surface. Deformation of the slide table surface may result in gaps, inability to achieve the specified preload causing looseness, or excessive preload leading to poor sliding performance. Therefore, it is recommended to maintain the flatness of the mounting surface at around 5 micrometers.
Example of Use
Mechanism name: Cotton swab glue application position adjustment
Introduction to application cases of MISUMI InCAD Library: economy manual stage
Application Industries
Electronics/Home Appliances Automotive Medical
MISUMI manual stage application scenario diagram for the electronics and home appliances field MISUMI manual stage application scenario diagram for the automotive industry MISUMI manual stage application scenario diagram for the medical device industry
Smartphones Semiconductors Lithium batteries
MISUMI manual stage application scenario diagram for the smartphone industry MISUMI manual stage application scenario diagram for the semiconductor industry MISUMI manual stage application scenario diagram for the lithium-ion battery industry
Related Products
Economical Electric Slide Table X-Axis Economical Electric Slide Table XY-Axis Economical Electric Slide Table Z-Axis
MISUMI economy electric X-axis linear ball guide stage C-XMBS series MISUMI economy electric X-axis linear ball guide stage C-XMBS series MISUMI economy electric Z-axis linear ball guide stage C-XMBS series
Representative model: C-XMBS420-L-A-2 Representative model: C-XYMBS420-L-A-2 Representative model: C-ZMBS420-L-A-2
Advantage: Low cost, fast delivery Advantage: Low cost, fast delivery Advantage: Low cost, fast delivery

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-XZSG80
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTable Size (Length) L
(mm)
Table Size (Width) W
(mm)
Stroke (Z Distance)
(mm)
Alteration

MYR 1,866.36

1 Piece(s)Available 13 Day(s) 8080±12.5Standard Type

Loading...

  1. 1
Product Overview
MISUMI E-XZSG series linear ball guide type positioning stages are economy series positioning stages. It can be used as a positioning stage for simple position adjustment. The body is made of D2 tool steel to achieve high rigidity; the surface is chemically nickel plated to provide a certain degree of rust resistance. Linear ball guide is used for guiding purpose, which meets the requirements of usage accuracy. Prices have been significantly reduced due to local production in China and improved machining process.
Product Features
Feature 1: Production cycle is shortened, shipped within 5 days at the earliest
Feature 2: Low price is achieved by simplifying the structure and improving the machining process.
Feature 3: A wide range of alterations are available to enable installation and operation under different conditions.
Feature 4: By improving the clamping mechanism, the holding force of the positioning stage is greater than that of the standard type clamping mechanism.
Specifications Overview
Type Material Surface TreatmentMovement (mm)Load Capacity (N)Straightness
E-XZSGD2 Tool SteelChemically Nickel Plating±6.5~±12.549Within 10 μm

■Amount of travel
  The catalog drawing size is the state of travel 0mm, and taking this as reference, the distance moved in the left and right directions is the amount of travel.

■Load capacity
 is the force in N that the positioning stage can withstand when the center of gravity of the workpiece is in the center of the positioning stage. If used in excess of the load capacity, the positioning stage may not move properly or get stuck. Refer to the values of "Horizontal" and "Vertical" for the load resistance for horizontal and vertical installation respectively. Note that when the linear motion positioning stage is installed vertically or upside down, the accuracy may be less than the value indicated in the catalog.

■Straightness
  The maximum offset relative to the ideal axis of movement (the line connecting the start and end points is shown as the red line in the figure below. The black line is the actual trajectory of movement.) when the positioning stage moves at full stroke. Detection method: Place the micrometer on the positioning stage, with the pointer held against the reference block, let the positioning stage move at full stroke, and measure its maximum displacement, which is the straightness.

Meaning of Straightness of MISUMI Manual Positioning StageDetection Method of MISUMI Manual Positioning Stage
Usage Method
■Installation Method of X-Axis Positioning Stage
   When mounting the positioning stage to the base, basically it is mounted by moving the positioning stage surface. Refer to the following diagram.
Standard Installation Method of MISUMI Manual X-Axis Positioning Stage
The above diagram is for demonstration purpose only. Refer to each catalog or 3D data for detailed shapes and specifications of the positioning stage.

■Mounting Posture
DiagramHorizontal Installation Diagram of MISUMI X-Axis Positioning Stage Inverted Installation Diagram of MISUMI X-Axis Positioning Stage  Side-Mounted Horizontal Installation Diagram of MISUMI X-Axis Positioning Stage Side-Mounted Vertical Installation Diagram of MISUMI X-Axis Positioning Stage
Mounting PostureHorizontalInvertedSide-Mounted HorizontalSide-Mounted Vertical
Load Resistance Characteristics
Horizontal, inverted, side-mounted horizontal or side-mounted vertical installation options are available. Other installation methods should be given more attention.
Load capacity and accuracy will change greatly depending on the mounting posture.
○:Same as horizontal load capacity.
△:About 1/3 of the horizontal load capacity is the approximate standard, if the catalog contains the vertical load capacity, it should be given priority.

■Vertical Use of X-Axis Positioning Stage
  When using the X-axis positioning stage vertically, pay attention to the feed direction, which should not be in the same direction as gravity.
  When using a micrometer knob type positioning stage, note that the positioning stage is reset by extension spring. If the force applied is greater than the spring load, the positioning stage surface may fall. For such occasions, alterations can be used as a solution.
Wrong Usage MethodCorrect Usage Method
(Usually) If the force applied exceeds the tensile load of the spring, the positioning stage surface may slip off because it cannot support the weight.After selecting the alteration of the micrometer knob position change, the positioning stage surface does not fall even when used vertically.
Example of wrongly using MISUMI X-axis positioning stage verticallyExample of correctly using MISUMI X-axis positioning stage vertically
Avoid applying loads that exceed the load carrying range in the vertical direction.
Example of Use
Mechanism name: Cotton swab glue application position adjustment
MISUMI InCAD Library Case Study on the Use of Economy Series Manual Positioning Stages
Example of Use
Electronics/Home Appliance Automotive Medical
Application Scenario Diagram of MISUMI Manual Positioning Stages in Electronics and Home Appliance Fields Application Scenario Diagram of MISUMI Manual Positioning Stages in Automotive Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Medical Device Industry
Smart Phones Semiconductor Lithium battery
Application Scenario Diagram of MISUMI Manual Positioning Stages in Smart Phone Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Semiconductor Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Lithium-Ion Battery Industry
Precautions
■Operating temperature and environment
  Recommended operating environment: 10~50℃, 20~70%RH (no condensation)
  Accuracy assurance environment: 22±5℃, 20~70%RH (no condensation)

■Guiding mechanism
  This positioning stage adopts crossed roller guide as the guiding mechanism. Please refill the lubricant at the right time according to the usage conditions to prevent the life of crossed roller guide from being shortened due to the decrease of lubricant and aging.

■Clamping mechanism
  ①The clamping mechanism of the positioning stage is fixed by the frictional force generated by the fastening screw, so when the applied external force exceeds the frictional force of the clamping mechanism section, it will cause the positioning stage to move. The user should take appropriate measures to avoid movement of the positioning stage surface during use. If clamping reinforcement is required, disc clamping or opposite clamping can be selected.
  ②The holding force is the value of the force that keeps the positioning stage surface from moving in the clamped condition. Since the maximum holding force varies with the tightening torque, please ensure a sufficiently large safety factor when designing.

■Feed mechanism
  The shape of a positioning stage with a micrometer knob installed as shown in the figure below is generally called the standard type. Free selection is possible by combining the installation space, mounting posture, and operation method. However, due to the structure of the product, there are some models where the installation position of the micrometer knob cannot be changed. For details, refer to the [Alteration] at the bottom of each product page.
Micrometer Knob Position Diagram of MISUMI Manual X-Axis Positioning Stage Standard Type

■Flatness of the mounting surface
The upper and lower positioning stage surface may be deformed due to the different flatness of its mounting surface. Deformation of the positioning stage surface may result in gaps, looseness due to failure to obtain the specified preload, or poor sliding due to excessive preload. Therefore, it is recommended that the flatness of the mounting surface be kept at about 5 microns.
Related Products
X-Axis Motorized Positioning Stages XY-Axis Motorized Positioning Stages Z-Axis Motorized Positioning Stages
MISUMI Economy series Electric X-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series MISUMI Economy series Electric X-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series MISUMI Economy series Electric Z-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series
Typical Model: C-XMBS420-L-A-2 Typical Model: C-XYMBS420-L-A-2 Typical Model: C-ZMBS420-L-A-2
Advantages: low price, fast delivery Advantages: low price, fast delivery Advantages: low price, fast delivery

Basic Information

Feeding Method Micrometer Head / Micrometer Head + Coarse Adjustment Head Table Material SUS440C Table Surface Treatment Electroless Nickel Plating
Travel Guide Linear Ball Load Capacity(N) 49 Z-Axis Stage Surface Horizontal Surface Z-Axis
Table Straightness(µm) 10

Please check the type/dimensions/specifications of the part E-XZSG80 in the XZ-Axis Manual Stages, Linear Ball Guide series.

Frequently asked question (FAQ)

Question: What does a micrometer knob-type positioning stage with a travel distance of ±XX mean?
Answer: The travel ±XXmm means how many millimeters can be moved in each direction, left and right or up and down, with the middle of the full travel of the micrometer knob as the base point.
Question: What is the reset method of the micrometer knob type manual positioning stage? What should be paid attention to in use?
Answer: The micrometer knob type manual positioning stage is reset by means of an extension spring. If the applied load is greater than the spring load, the positioning stage surface may not reset properly or the spring may be damaged directly, so take care when using it.
Question: Can the positioning stage be mounted vertically? What should be paid attention to?
Answer: Yes, it can. However, attention should be paid that the load capacity is about 1/3 of that for horizontal installation; and that the feed direction should not be the same as gravity direction, because if the applied force is greater than the spring load, the positioning stage surface may not be able to support the weight and may fall.
Question: Can manual positioning stage products be used upside down?
Answer: All except dovetail products. Dovetail products are strictly forbidden to be used upside down.
Question: Is it possible to freely assemble the XY type positioning stage without the dimension or travel I want?
Answer: Yes, it is.

Check other FAQ (2 items) Hide

Products like this...

Part Number
E-XZSG40-CU
E-XZSG40-R
E-XZSG50
E-XZSG80-A
E-XZSG80-C
E-XZSG80-CU
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTable Size (Length) L
(mm)
Table Size (Width) W
(mm)
Stroke (Z Distance)
(mm)
Alteration

MYR 1,167.58

1 Piece(s)Available 13 Day(s) 4040±6.5CU [Change knob position: side, down]

MYR 1,167.58

1 Piece(s)Available 13 Day(s) 4040±6.5R [Change feed knob position: reversed]

MYR 1,068.52

1 Piece(s) 16 Day(s) 5050±6.5Standard Type

MYR 1,866.36

1 Piece(s)Available 13 Day(s) 8080±12.5A [Change knob position: center]

MYR 1,866.36

1 Piece(s)Available 13 Day(s) 8080±12.5C [Change knob position: side]

MYR 1,866.36

1 Piece(s)Available 13 Day(s) 8080±12.5CU [Change knob position: side, down]

Additional Products in this Category

Tech Support