Temperature Sensors Screw Mount Bendable K-Thermocouple

Temperature Sensors Screw Mount Bendable K-Thermocouple

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Temperature Sensors Screw Mount Bendable K-Thermocouple
These Temperature Sensors Thermocouple type K are an economy item, The price is cheaper than the MISUMI standard product.They offer a wide variety of sizes to choose from.
[Feature]
● Temperature Sensors : Thermocouple Type K
● Screw Size: M6 X 1.0
● Wire Length (m.): 1, and 5
● Temperature Range (°C) : 0-150
● Crimp Terminal Type: Y-Shaped 2 sets
[Application]
It is used in a variety of application such as heat treatment, packaging industry , plastic industry , and so on.



Economy Bendable K-Thermocouple

Bendable Design Screw Mounting Durable Construction

- Bendable K-Thermocouple. Allows for installation in tight or awkward spaces, enhancing adaptability and ease of use in complex environments.

- Specific screw size provided.

- Silicon rubber film insulation. Provides robust protection against environmental factors, ensuring long-lasting performance and reliability.

- Measures temperatures from 0 to 150°C. Suitable for a broad range of industrial processes, ensuring accurate temperature monitoring in diverse environments.

- Grounded type temperature measurement contact point. Ensures quick response to temperature changes, providing precise and timely data for critical processes.

Economy Bendable K-Thermocouple
MISUMI Economy Logo

MISUMI Standard
MISUMI Standard

Cheaper Price
Cheaper Price

Product Variety
Product Variety

3D CAD
3D CAD Support

Temperature Sensors Product Overview

Temperature Sensors
The thermocouple consists of two wires made of different materials, which are welded together at the end. After the ambient temperature of the unheated part is measured, the temperature of the heating point can be accurately known. Because it must have the conductor made of two different materials, it is called the thermocouple. The thermocouples made of different materials can be used in different temperature ranges, and their sensitivities are different from each other. The sensitivity of a thermocouple refers to the change in the output potential difference when the temperature of the heating point changes by 1°C. For most metal-supported thermocouples, this value is between 5-40 µV/°C.

PT100
PT100 is a platinum thermal resistance, and its resistance value is proportional to the change of temperature. 100 after PT means that its resistance value is 100 ohms at 0°C and about 138.5 ohms at 100°C.

Temperature Sensors Dimensional Drawing

Dimensional Drawing
Temperature Sensors For more information on product dimensional drawings, please refer to the product catalog.

Temperature Sensors Specification Table

Temperature Sensors TypeSensor Type
F(m)
Screw SizeSensor TypeTemperature RangeWire Operating
Temperature Range
C-MFNC61M6×1.0K-Thermocouple0 to 150℃150°C
5

Temperature Sensors Product Features

Genuine material and guaranteed wire diameter
Fast temperature response
More detailed improvements
Various mounting head types

Temperature Sensors Precautions

PrecautionsTemperature Sensors Precautions for use
To extend the thermocouple lead wire, please use the compensation lead wire.
Please strictly observe the heat resistant temperature of each part in product page. Please note that even the upper limit of the Temperature Sensors measurement is very high, malfunctions such as wire breakage may occur if the heat-resistant temperature is exceeded.
Do not apply large external force or vibration.
Please pay attention to the heat resistance temperature of the silicon tube part of the ·sleeve.
Please keep the upper limit of the temperature below the temperature measurement range of the product. If the bushing temperature exceeds the heat-resistant temperature, it is very easy to cause the breakage of the temperature measurement wire.
If the Temperature Sensors of heat generating parts exceeds 100°C, please choose the specification with a front end as long as possible.
Precautions

Temperature Sensors Usage Method

TThermocouples should not be installed too close to the door or the heater. It is sufficient to make the front end of the thermocouple come into contact with the object to be measured. The gap between the sheath and protection sheath and the mounting hole if not filled with insulation may cause overheating or cold air to enter the heating chamber. Therefore, this gap must be filled with insulating material such as insulating earth to stabilize the heat in the chamber. Air convection affects the accuracy of the heating process. The sleeve should not be installed too close to the heating chamber to avoid exceeding 100°C. The installation of the thermocouple should be avoided as much as possible from strong magnetic and electric fields. Therefore, the thermocouple and power cable should not be installed close to each other to avoid errors caused by signal interference. Do not install the thermocouple with the low-flow measuring medium. When measuring the gas temperature inside the tube, the thermocouple needs to be installed in the opposite direction of circulation and in full contact with the gas.

Temperature Sensors Related Products

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
C-MFNC6-1
C-MFNC6-5
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipLead Wire Length (F)
(m)

MYR 30.40

1 Piece(s)Available 6 Day(s) 1

MYR 63.08

1 Piece(s)Available 1 Day(s) 5

Loading...

  1. 1

Brand introduction

MISUMI, the head office company, has been providing customers with various high-quality parts such as automation parts, mold parts, electronic parts, tool & consumables, etc. quickly and accurately since its establishment in Japan in 1963. By compiling product catalogs independently and establishing a marketing system for direct sales of products, a low-cost business operation mode has been created, and by making annual product plans according to customers' opinions and requirements, MISUMI brand-name products with high quality level have been continuously developed

Basic Information

Type of Temperature Sensor Thermocouple Type of Thermocouple K Thermocouple Sheath, Protection Tube Diameter(Ø) 4.3
Measurement Object Temperature Sensor Temperature Measurement Contact Point Grounded Type Operating Temperature Range(°C) 0::150
Sheath, Protecting Tube's Thread Nominal M6

Frequently asked question (FAQ)

Question: What are the main types of sensors currently sold by MISUMI?
Answer: Photoelectric sensors, proximity sensors, pressure sensors, temperature sensors, etc.
Question: What is a photo microsensors?
Answer: With an amplifier, an emitter and a receiver built in its integrated main body, it is a sensor that is easy to install and adjust, usually designed for detecting the passage of workpieces on the conveying line and for positioning workpieces, etc.
Question: What are the features of the photoelectric sensor?
Answer: 1. The action (response time) is very fast because light is used as the medium.
2. It has a longer detection distance than the light sensor and allows for remote detection.
3. Objects made of almost any material can be detected as long as they reflect light.
Question: What are the detection methods of the photoelectric sensor?
Answer: Transmittance type, regression reflection type, diffusion reflection type, limited reflection type, etc.

Check other FAQ (1 items) Hide

Additional Products in this Category

Tech Support